20 WATTS OUTPUT POWER
•
2:1 AND 4:1 WIDE INPUT VOLTAGE RANGE
•
INTERNATIONAL SAFETY STANDARD APPROVAL
•
SIX-SIDED CONTINUOUS SHIELD
•
HIGH EFFICIENCY UP TO 86%
•
STANDARD 2” X 1.6” X 0.4” PACKAGE
•
FIXED SWITCHING FREQUENCY
The FDC20 and FDC20-W series offer 20 Watts of output power from a 2 x 1.6 x 0.4 inch
package. The FDC20 series with 2:1 wide input voltage of 9-18, 18-36 and 36-75VDC.
The FDC20-W series with 4:1 wide input voltage of 9-36 and 18-75VDC. The FDC20
and FDC20-W features 1600VDC of isolation, short-circuit and over-voltage protection,
as well as six sided shielding. A safety approval to EN60950 and UL1950. All models are
particularly suited to telecommunications, industrial, mobile telecom and test equipment
applications.
UL E193009
TUV R2054535
CB JPTUV-001393
CE MARK
T E C H N I C A L S P E C I F I C AT I O N
OUTPUT SPECIFICATIONS
Output power
Voltage accuracy Full load and nominal Vin
Voltage adjustability
Minimum load (Note 1)
Line regulation
LL to HL at Full Load
Single (W)
Dual (W)
Triple 3.3V/5V
Auxiliary
Single
Dual
Triple 3.3V/5V
Auxiliary
Dual
Triple 3.3V/5V
Auxiliary
Single
Dual
Triple 3.3V/5V
Auxiliary
All specifications are typical at nominal input, full load and 25ºC otherwise noted
GENERAL SPECIFICATIONS
20 Watts max
Single & Dual
Triple 3.3V/5V
Auxiliary
± 2%
± 2%
± 5%
± 10%
10% of FL
± 0.2%
± 0.5%
± 1%
± 5%
± 0.5%
± 3%
± 2%
± 5%
± 5%
± 2%
± 5%
75mVp-p
100mVp-p
50mVp-p
1% of Vout
500uS
3.9V
6.2V
15V
18V
Hiccup, automatics recovery
Efficiency
Isolation voltage
Isolation resistance
Isolation capacitance
Switching frequency
Approvals and standard
Case material
Base material
Potting material
Dimensions
Weight
MTBF (Note 5)
9
See table
1600VDC, min
10 ohms, min
300pF, max
300KHz, typ
IEC60950, UL1950, EN60950
Nickel-coated copper
Non-conductive black plastic
Epoxy (UL94-V0)
2.00 X 1.60 X 0.40 Inch
(50.8 X 40.6 X 10.2 mm)
48g (1.69oz)
1.928 x 10
6
hrs
Load regulation
25% to 100% FL
Cross regulation (Note 2)
Ripple and noise 20MHz bandwidth
Temperature coefficient
3.3V output
Over voltage protection 5V output
Zener diode clamp
12V output
15V output
Short circuit protection
ENVIRONMENTAL SPECIFICATIONS
Operating temperature range
Maximum case temperature
Storage temperature range
Thermal impedance (Note 6)
Thermal shock
Vibration
Relative humidity
Nature convection
Nature convection with heat-sink
-40ºC ~ +85ºC (with derating)
+100ºC
-55ºC ~ +105ºC
10ºC/watt
8.24ºC/watt
I0.02%
/ ºC, max
Transient response recovery time 25% load step change
MIL-STD-810D
10~55Hz, 2G, 30minutes along X,Y and Z
5% to 95% RH
INPUT SPECIFICATIONS
FDC20
Input voltage range
12V nominal input
24V nominal input
48V nominal input
FDC20-W 24V nominal input
48V nominal input
12V input
24V input
48V input
9 – 18VDC
18 – 36VDC
36 – 75VDC
9 – 36VDC
18 – 75VDC
Pi type
36VDC
50VDC
100VDC
25mAp-p
20mS typ
EMC CHARACTERISTICS
Conducted emissions
Radiated emissions
ESD
Radiated immunity
Fast transient
Surge
Conducted immunity
EN55022
EN55022
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN61000-4-5
EN61000-4-6
Level A
Level A
Perf. Criteria2
Perf. Criteria2
Perf. Criteria2
Perf. Criteria2
Perf. Criteria2
Input filter
Input surge voltage
100mS max
Input reflected ripple
Nominal Vin and full load
(Note 3)
Start up time
Nominal Vin and constant resistor load
Remote ON/OFF (Note 4)
DC-DC ON
DC-DC OFF
Nominal input
Remote off input current
Open or 3.5V < Vr < 12V
Short or 0V < Vr < 1.2V
20mA
Model
Number
Input
Range
Output
Voltage
Output
Current
4000mA
4000mA
1670mA
1330mA
± 2000mA
± 833mA
± 666mA
3000 / ± 300mA
3000 / ± 250mA
2000 / ± 300mA
2000 / ± 250mA
4000mA
4000mA
1670mA
1330mA
± 2000mA
± 833mA
± 666mA
3000 / ± 300mA
3000 / ± 250mA
2000 / ± 300mA
2000 / ± 250mA
4000mA
4000mA
1670mA
1330mA
± 2000mA
± 833mA
± 666mA
3000 / ± 300mA
3000 / ± 250mA
2000 / ± 300mA
2000 / ± 250mA
Input
(7)
Current
1507mA
2193mA
2136mA
2136mA
2193mA
2136mA
2136mA
1926mA
1959mA
1885mA
1919mA
743 (764mA)
1082 (1111mA)
1054 (1082mA)
1054 (1082mA)
1082 (1111mA)
1054 (1082mA)
1041 (1068mA)
950mA
967mA
931mA
947mA
367 (377mA)
543 (548mA)
527 (541mA)
527 (541mA)
541 (556mA)
514 (527mA)
508 (521mA)
468mA
477mA
459mA
467mA
Eff
(%)
(8)
Capacitor
Load max
(9)
FDC20-12S33
9 – 18 VDC
3.3 VDC
FDC20-12S05
9 – 18 VDC
5 VDC
FDC20-12S12
9 – 18 VDC
12 VDC
FDC20-12S15
9 – 18 VDC
15 VDC
FDC20-12D05
9 – 18 VDC
± 5 VDC
FDC20-12D12
9 – 18 VDC
± 12 VDC
FDC20-12D15
9 – 18 VDC
± 15 VDC
FDC20-12T3312
9 – 18 VDC
3.3 / ± 12 VDC
FDC20-12T3315
9 – 18 VDC
3.3 / ± 15 VDC
FDC20-12T0512
9 – 18 VDC
5 / ± 12 VDC
FDC20-12T0515
9 – 18 VDC
5 / ± 15 VDC
FDC20-24S33 (W)
18 – 36 (9 – 36) VDC
3.3 VDC
FDC20-24S05 (W)
18 – 36 (9 – 36) VDC
5 VDC
FDC20-24S12 (W)
18 – 36 (9 – 36) VDC
12 VDC
FDC20-24S15 (W)
18 – 36 (9 – 36) VDC
15 VDC
FDC20-24D05 (W)
18 – 36 (9 – 36) VDC
± 5 VDC
FDC20-24D12 (W)
18 – 36 (9 – 36) VDC
± 12 VDC
FDC20-24D15 (W)
18 – 36 (9 – 36) VDC
± 15 VDC
FDC20-24T3312
18 – 36 VDC
3.3 / ± 12 VDC
FDC20-24T3315
18 – 36 VDC
3.3 / ± 15 VDC
FDC20-24T0512
18 – 36 VDC
5 / ± 12 VDC
FDC20-24T0515
18 – 36 VDC
5 / ± 15 VDC
FDC20-48S33 (W)
36 – 75 (18 – 75) VDC
3.3 VDC
FDC20-48S05 (W)
36 – 75 (18 – 75) VDC
5 VDC
FDC20-48S12 (W)
36 – 75 (18 – 75) VDC
12 VDC
FDC20-48S15 (W)
36 – 75 (18 – 75) VDC
15 VDC
FDC20-48D05 (W)
36 – 75 (18 – 75) VDC
± 5 VDC
FDC20-48D12 (W)
36 – 75 (18 – 75) VDC
± 12 VDC
FDC20-48D15 (W)
36 – 75 (18 – 75) VDC
± 15 VDC
FDC20-48T3312
36 – 75 VDC
3.3 / ± 12 VDC
FDC20-48T3315
36 – 75 VDC
3.3 / ± 15 VDC
FDC20-48T0512
36 – 75 VDC
5 / ± 12 VDC
FDC20-48T0515
36 – 75 VDC
5 / ± 15 VDC
(10)
FDC20-24D3305
FDC20-48D3305, Output 3.3V(3A)/5V(2A), Detail Spec. Contact Factory.
77
80
82
82
80
82
82
78
78
80
80
78 (76)
81 (79)
83 (81)
83 (81)
81 (79)
83 (81)
84 (82)
79
79
81
81
79 (77)
82 (80)
83 (81)
83 (81)
81 (79)
85 (83)
86 (84)
80
80
82
82
13000uF
6800uF
2200uF
755uF
± 3400uF
± 680uF
± 450uF
4700 / ± 220uF
4700 / ± 220uF
4700 / ± 220uF
4700 / ± 220uF
13000uF
6800uF
2200uF
755uF
± 3400uF
± 680uF
± 450uF
4700 / ± 220uF
4700 / ± 220uF
4700 / ± 220uF
4700 / ± 220uF
13000uF
6800uF
2200uF
755uF
± 3400uF
± 680uF
± 450uF
4700 / ± 220uF
4700 / ± 220uF
4700 / ± 220uF
4700 / ± 220uF
Note
The FDC20 series required a minimum 10% loading on the output to maintain specified regulation. Operation under no-load condition will not damage
these devices, however they may not meet all listed specification.
2. Cross regulation:
Dual output—Asymmetrical load 25% to 100% full load
Triple output – 3.3V / 5V 100% load and one of auxiliary 100% load, other auxiliary load change from 25% to 100% load
3. Simulated source impedance of 12uH. 12uH inductor in series with +Vin.
4. The ON/OFF control pin voltage is referenced to negative input
5. BELLCORE TR-NWT-000332. Case I: 50% Stress, Temperature at 40ºC. (Ground fixed and controlled environment)
6. Heat sink is optional and P/N: 7G-0011A.
Operation temperature range please see curve.
7. Maximum value at nominal input voltage and full load.
8. Typical value at nominal input voltage and full load.
9. Test by minimum Vin and constant resistor load.
10. The FDC20-24D3305 and FDC20-48D3305 are safety approval pending.
FDC20-48S05 Derating Curve
OUTPUT POWER (%)
OUTPUT POWER (%)
1.
FDC20-48S05 Derating Curve
With HEAT-SINK (Note 6)
100
75
50
100
75
50
Nature convection
25
0
-40 -25 -10 0
Nature convection
25
0
-40 -25 -10 0
50 60 70 80 90 100
AMBIENT TEMPERATURE (ºC)
50 60 70 80 90 100
AMBIENT TEMPERATURE (ºC)