F381103C5.0

Description
Barrier Strip Terminal Block, 30A, 1 Row(s), 1 Deck(s)
CategoryThe connector    terminals   
File Size208KB,1 Pages
ManufacturerCooper Industries
Download Datasheet Parametric View All

F381103C5.0 Overview

Barrier Strip Terminal Block, 30A, 1 Row(s), 1 Deck(s)

F381103C5.0 Parametric

Parameter NameAttribute value
MakerCooper Industries
Reach Compliance Codeunknown
ECCN codeEAR99
Fastening methodSCREW
Manufacturer's serial numberF38
Installation typePANEL
Number of layers1
Rows1
Number of channels3
Rated current30 A
Rated voltage300 V
safety certificateUL; CSA; CE
Terminal and terminal strip typesBARRIER STRIP TERMINAL BLOCK
Wire gauge10 AWG
F38 Series Filtered Terminal Blocks
SPECIFICATIONS
Ratings:
30A, 240VAC, 300VDC.
Center Spacing:
0.437" or 7/16" (11.10mm)
Wire Size:
# 10-22 AWG CU
Screw Size:
# 8-32 (# 6-32 available, consult factory)
Torque Rating:
15 in-lb.
Operating Temperature:
–55°C to +105°C.
Housing Material:
94VO Thermoplastic.
Molded Material:
Black, UL rated 94V0 thermoplastic.
Terminal Material:
Brass, Tin-Plated
Capacitance:
1,000 pF to 5,000 pF in either C or Pi Schematic
Dielectric Withstanding Voltage:
1000 VAC; 1700VDC
D.C. Resistance:
0.01 ohms max.
Agency Information:
UL/CSA, CE Certified
# of
Poles
2
3
4
5
6
7
8
A
A
Front Mount Rear Mount
1.67
2.10
2.54
2.98
3.41
3.85
4.29
1.88
2.32
2.76
3.19
3.63
4.07
4.51
B
C
D
FEATURES
• Rugged integrated construction of filtering elements
around a solid brass pin provides excellent EMI/RFI
filtering
• Filter element provides high insertion loss for EMI/RFI
filtering of AC and DC power and control lines
• 2 to 8 terminals standard – up to 16 poles available
• Cost-effective EMI solution for industrial interconnec-
tion filtering
• Termination options are straight lead, male or female
quick connect
• Custom and special options available including:
– Different capacitance values on each position
– Wire assemblies added to pins
Insertion Loss for 2,500 pF Pi Schematic
Typical Insertion Loss (dB) in 50 Ohm Circuit
30MHz . . . . . . . . . . .42 dB
50 MHz . . . . . . . . . . .45 dB
100 MHz . . . . . . . . . .50 dB
300 MHz . . . . . . . . . .68 dB
1000 MHz . . . . . . . . .70 dB
Single & Double Row
Filtered Connectors
Euro-MAG Series
PCB – Spring Clamp
1.31
1.75
2.19
2.63
3.06
3.50
3.94
0.93
1.37
1.81
2.25
2.68
3.12
3.56
0.44
0.88
1.31
1.75
2.19
2.62
3.06
* Note: For other capacitance insertion loss, consult factory.
* Note: In inches. Available up to 16 poles. Consult factory.
O - Front Panel Mount
I - Rear Panel Mount
Base & Rail Mount
Connectors
Power Distribution Blocks
Part Numbering System
Series
Terminal Style
Mounting
# of Poles
Screw Options
Inches (Millimeters)
Filter Options
Capacitance
F 3 8
0
- straight lead
0
- front panel mount
02
to
08*
1
- 0.187" quick
with mount ends
connect (male)
1
- rear panel mount
2
- 0.187" quick
with #4-40 threaded inserts
connect (male)
3
- 0.250" quick
connect (male)
4
- 0.250" quick
connect (female)
Blank
- #8-32, steel, zinc plated
philslot BHMS (stnadard)
04
- #8-32, brass, nickel plated
philslot BHMS
92
- #8-32, steel, zinc plated
slotted BHMS
94
- #8-32, brass, nickel plated
slotted BHMS
C
- C Filter
P
- Pi Filter
.
1.0
- 1,000 pF + 100%-0%
2.5
- 2,500 pF + 100%-0%
5.0
- 5,000 pF + 100%-0%
WIRE MANAGEMENT PRODUCTS
* Note: Standard is 02-08 poles. Available up to 16 poles. Consult factory for availability.
Special electrical/mechanical configurations are available upon request from factory.
25
RS485 driver problem under ucos
Hey guys, have you ever made RS485 driver under ucos? The problem I'm facing now is: When running the 485 driver under bare metal, the interrupt and receiving and sending are completely correct. But w...
dragonled Real-time operating system RTOS
Motor driver chip L298N data
Motor driver chip L298N data Motor driver chip L298N data...
美目如初 Motor Drive Control(Motor Control)
I have information about LM317!! Hahahaha
LM317 data, PDF...
西门 Embedded System
Did you know that our section has a monthly best selection award?
[size=4]This is the details of the event. It has been successfully selected for two months. [/size][b][size=4]EEworld MSP430 Monthly Best Project Activity Details (Preparation) - by wstt[/size][/b][si...
wstt Microcontroller MCU
Advantages of Embedded Linux
In fact, there are many advantages to learning Linux . The Linux kernel can be said to be the epitome of the entire open source software community. In the past few decades, a large number of world-cla...
XYD漫漫 Linux and Android
[AN-770 Application Note] iCoupler Isolation in CAN Bus Applications
Introduction: The Controller Area Network (CAN) bus is a stable protocol designed for industrial applications and was originally developed for automotive applications....
EEWORLD社区 ADI Reference Circuit

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 816  1831  55  680  2379  17  37  2  14  48 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号