Part Number

Search

F381106P5.0

Description
Barrier Strip Terminal Block, 30A, 1 Row(s), 1 Deck(s)
CategoryThe connector    terminals   
File Size208KB,1 Pages
ManufacturerCooper Industries
Download Datasheet Parametric View All

F381106P5.0 Overview

Barrier Strip Terminal Block, 30A, 1 Row(s), 1 Deck(s)

F381106P5.0 Parametric

Parameter NameAttribute value
MakerCooper Industries
Reach Compliance Codeunknown
ECCN codeEAR99
Fastening methodSCREW
Manufacturer's serial numberF38
Installation typePANEL
Number of layers1
Rows1
Number of channels6
Rated current30 A
Rated voltage300 V
safety certificateUL; CSA; CE
Terminal and terminal strip typesBARRIER STRIP TERMINAL BLOCK
Wire gauge10 AWG
F38 Series Filtered Terminal Blocks
SPECIFICATIONS
Ratings:
30A, 240VAC, 300VDC.
Center Spacing:
0.437" or 7/16" (11.10mm)
Wire Size:
# 10-22 AWG CU
Screw Size:
# 8-32 (# 6-32 available, consult factory)
Torque Rating:
15 in-lb.
Operating Temperature:
–55°C to +105°C.
Housing Material:
94VO Thermoplastic.
Molded Material:
Black, UL rated 94V0 thermoplastic.
Terminal Material:
Brass, Tin-Plated
Capacitance:
1,000 pF to 5,000 pF in either C or Pi Schematic
Dielectric Withstanding Voltage:
1000 VAC; 1700VDC
D.C. Resistance:
0.01 ohms max.
Agency Information:
UL/CSA, CE Certified
# of
Poles
2
3
4
5
6
7
8
A
A
Front Mount Rear Mount
1.67
2.10
2.54
2.98
3.41
3.85
4.29
1.88
2.32
2.76
3.19
3.63
4.07
4.51
B
C
D
FEATURES
• Rugged integrated construction of filtering elements
around a solid brass pin provides excellent EMI/RFI
filtering
• Filter element provides high insertion loss for EMI/RFI
filtering of AC and DC power and control lines
• 2 to 8 terminals standard – up to 16 poles available
• Cost-effective EMI solution for industrial interconnec-
tion filtering
• Termination options are straight lead, male or female
quick connect
• Custom and special options available including:
– Different capacitance values on each position
– Wire assemblies added to pins
Insertion Loss for 2,500 pF Pi Schematic
Typical Insertion Loss (dB) in 50 Ohm Circuit
30MHz . . . . . . . . . . .42 dB
50 MHz . . . . . . . . . . .45 dB
100 MHz . . . . . . . . . .50 dB
300 MHz . . . . . . . . . .68 dB
1000 MHz . . . . . . . . .70 dB
Single & Double Row
Filtered Connectors
Euro-MAG Series
PCB – Spring Clamp
1.31
1.75
2.19
2.63
3.06
3.50
3.94
0.93
1.37
1.81
2.25
2.68
3.12
3.56
0.44
0.88
1.31
1.75
2.19
2.62
3.06
* Note: For other capacitance insertion loss, consult factory.
* Note: In inches. Available up to 16 poles. Consult factory.
O - Front Panel Mount
I - Rear Panel Mount
Base & Rail Mount
Connectors
Power Distribution Blocks
Part Numbering System
Series
Terminal Style
Mounting
# of Poles
Screw Options
Inches (Millimeters)
Filter Options
Capacitance
F 3 8
0
- straight lead
0
- front panel mount
02
to
08*
1
- 0.187" quick
with mount ends
connect (male)
1
- rear panel mount
2
- 0.187" quick
with #4-40 threaded inserts
connect (male)
3
- 0.250" quick
connect (male)
4
- 0.250" quick
connect (female)
Blank
- #8-32, steel, zinc plated
philslot BHMS (stnadard)
04
- #8-32, brass, nickel plated
philslot BHMS
92
- #8-32, steel, zinc plated
slotted BHMS
94
- #8-32, brass, nickel plated
slotted BHMS
C
- C Filter
P
- Pi Filter
.
1.0
- 1,000 pF + 100%-0%
2.5
- 2,500 pF + 100%-0%
5.0
- 5,000 pF + 100%-0%
WIRE MANAGEMENT PRODUCTS
* Note: Standard is 02-08 poles. Available up to 16 poles. Consult factory for availability.
Special electrical/mechanical configurations are available upon request from factory.
25
Automobile front axle precision forming die CAD/CAM2
3. 3D CAD/CAM for precision roll forging and precision die forging of front axle. Since the design accuracy is low when using 2D CAD software (such as AutoCAD or InterCAD), it cannot meet the design r...
frozenviolet Automotive Electronics
Can this thin wire pass 3A of current?
This is the circuit board we soldered, but I am worried that the connecting wire at the back is too thin and cannot pass the 3A current. I wonder if this thin wire can be used?...
electricor Power technology
Should DVB-H use L-Band or UHF band? .pdf
Should DVB-H use the L-Band or UHF band? The following article will give you a different view....
JasonYoo Test/Measurement
Classic: Ten Steps of SMT
Classic: Ten Steps of SMT...
fighting Industrial Control Electronics
About the problem of baud rate mismatch during USART communication
[font=微软雅黑][size=4] When sending data to the serial assistant through the USART serial port of CC2530, due to a step of carelessness, the baud rate was set incorrectly. However, stable data was obtain...
Taurus_Xp MCU
Giant's 30.5 billion acquisition of a gaming company was suddenly suspended due to a major matter investigation
[align=left][color=#000][font=Arial, Verdana, sans-serif][size=13.3333px][font=宋体][size=4] The deal of Great Network to acquire Israeli game technology company Playtika for 30.5 billion yuan suddenly ...
tlyl18108837711 Integrated technical exchanges

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2096  792  2580  1395  1093  43  16  52  29  22 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号