Low Voltage Supplementary Fuses
Pin indication Fuses
GBA
GLD
Specifications
Class:
Supplemental
Description:
Fast-acting, pin
indication fuse.
Dimensions:
1
⁄
4
” x 1
1
⁄
4
”
(6.6 x 31.7mm) 3AG.
Construction:
Fiber tube
Ratings:
Volts — See Agency Info below
Amps —
1
⁄
2
-15A
IR — See Agency Info below
Agency Information:
CE, Std. 248-
14, UL Listed, 0-5A/125Vac, 10,000
AIC, Guide JDYX, File E19180, UL
Recognized, 6A/125Vac, 1000AIC
8-15A/50Vac/dc, 300 AIC Guide
JDYX2, File E19180, CSA Certified:
0-5A/125Vac, 10,000 AIC Class
1422-01, File 53787.
Features and Benefits
• Type GBA has a “red” pin indicator
providing visual identification of failed
circuits, resulting in faster
troubleshooting (reduced circuit
downtime).
• Type GLD has an plated pin to
activate transmitting a electrical
signal to indicate the location of
opened circuits, resulting in reduced
downtime.
Typical Applications
• Control Circuits
• Electronic Circuits
GLD Catalog Numbers (Amps)
GLD-
1
⁄
2
GLD-
3
⁄
4
GLD-1
GLD-1 ⁄
2
1
MIC & MIN
Specifications
Class:
Supplemental
Description:
Fast-
acting, pin indication
fuse.
Dimensions:
13
⁄
32
” x 1
1
⁄
2
” (10.3 x
38.1mm) 5AG.
Construction:
Fiber tube
Ratings:
Volts — 250Vac (1-15A)
— 32V (20-30A)
Amps — 1-30A
IR — 35A (1A @250Vac)
— 100A (2-3A @250Vac)
— 200A (5-10A @250Vac)
— 750A (15A @250Vac)
— 10,000A (20-30A @32V)
— 35A (1A @250Vac)
Agency Information:
CE, Std. 248-14,
MIC—0-15A UL Listed, Guide JDYX,
File E19180, MIN—1-5A CSA Certified,
Class 1422-01, File 53787.
Features and Benefits
•
Type MIN has a “red” pin indicator
providing visual identification of failed
circuits, resulting in faster trouble
shooting (reduced circuit downtime).
•
Type MIC has silver-plated pin transmit-
ting an electrical signal indicating
location of a failed circuit, resulting in
faster troubleshooting (reduced circuit
downtime).
Typical Applications
•
Control Circuits
•
PLC Circuits
•
Electronic Circuits
MIC Catalog Numbers (Amps)
MIC-1
MIC-5
MIC-10
MIC-15
MIC-20
MIC-25
MIC-30
MIC-2
MIC-3
FNA
Specifications
Class:
Supplemental
Description:
Time-delay,
pin indication fuse.
Dimensions:
13
⁄
32
” x 1
1
⁄
2
”
(10.3 x 38.1mm).
Construction:
Fiber tube
Ratings:
Volts — 250Vac (
1
⁄
10
-
8
⁄
10
A)
— 125Vac (1-15A)
— 32V (20-30A)
Amps —
1
⁄
10
-30A
IR — 35A (
1
⁄
10
-
8
⁄
10
A @ 250Vac)
— 10,000A (
1
⁄
10
-15A @ 125Vac)
— 1000A (20-30A @ 32V)
Agency Information:
CE, Std. 248-
14, UL Listed
1
⁄
10
-
8
⁄
10
A, IR 35A@ 250V,
IR 10kA@ 125V , 1-15A, IR 10kA@
125V, Guide JDYX, File 19180, CSA
Certified, 0-
8
⁄
10
A/250V, 1-10A/125V,
Class 1422-01, File 53787.
Features and Benefits
• FNA has a pin indicator providing
visual identification of failed circuits,
resulting in reduced circuit downtime.
• Time-delay response allows close
sizing on control transformers and
relays
Typical Applications
• Control Circuits
• Electronic Circuits
Catalog Numbers (Amps)
FNA-
1
⁄
10
FNA-
1
⁄
8
FNA-
15
⁄
100
FNA-
2
⁄
10
FNA-
1
⁄
4
FNA-
3
⁄
10
FNA-
4
⁄
10
FNA-
1
⁄
2
FNA-
6
⁄
10
FNA-
3
⁄
4
FNA-
8
⁄
10
FNA-1
FNA-1
1
⁄
8
FNA-1
1
⁄
4
FNA-1
4
⁄
10
FNA-1
1
⁄
2
FNA-1
6
⁄
10
FNA-1
8
⁄
10
FNA-2
FNA-2
1
⁄
4
FNA-2
FNA-2
FNA-3
FNA-3
FNA-3
FNA-4
FNA-4
FNA-5
FNA-5
FNA-6
1
Low Voltage
Supplementary
Fuses
⁄
2
8
⁄
10
2
1
GLD-2
GLD-3
GLD-4
GLD-5
GLD-6
GLD-10
GLD-12
GLD-15
⁄
10
⁄
2
⁄
2
⁄
10
1
GBA Catalog Numbers (Amps)
GBA- ⁄
2
1
6
GBA-2
GBA-3
GBA-4
GBA-5
GBA-8
GBA-10
GBA-15
FNA-6
1
⁄
4
FNA-7
FNA-8
FNA-9
FNA-10
FNA-12*
FNA-15*
FNA-20*
FNA-25*
FNA-30
GBA-
3
⁄
4
GBA-1
GBA-1
1
⁄
2
MIC - (1-15)UL Listed 125Vac / IR = 10kA
*12-30A versions are dual-tube construction
MIN Catalog Numbers (Amps)
MIN-1
MIN-2
MIN-5
MIN-10
MIN-20
MIN-25N
Recommended fuse blocks/fuse
holders for
1
⁄
4
” x 1
1
⁄
4
” indicating fuses
Recommended signal block for
13
Recommended signal block for
13
⁄
32
” x 1
1
⁄
2
” indicating fuses
⁄
32
” x 1
1
⁄
2
” indicating fuses
• Page 41
Data Sheet: 2012
• Page 41
Data Sheet: 2047
• Page 41
Data Sheet: 2029
For product data sheets, visit www.cooperbussmann.com/products/datasheet.asp
47