EEWORLDEEWORLDEEWORLD

Part Number

Search

FNA-8/10

Description
Electric Fuse, Time Delay Blow, 8.8A, 250VAC, 35A (IR), Inline/holder
CategoryCircuit protection    Circuit protection   
File Size64KB,1 Pages
ManufacturerCooper Industries
Download Datasheet Parametric View All

FNA-8/10 Overview

Electric Fuse, Time Delay Blow, 8.8A, 250VAC, 35A (IR), Inline/holder

FNA-8/10 Parametric

Parameter NameAttribute value
MakerCooper Industries
Reach Compliance Codeunknown
Fusing characteristicsTIME DELAY
body height38.1 mm
Body length or diameter20.75 mm
Built-in featuresINDICATOR
Circuit protection typeELECTRIC FUSE
Manufacturer's serial numberFNA
Installation featuresINLINE/HOLDER
method of packingBOX
physical size20.75mm x 38.1mm
Rated breaking capacity35 A
Rated current8.8 A
Rated voltage (AC)250 V
GuidelineCSA; UL
surface mountNO
Terminal shapeEND CAP
Low Voltage Supplementary Fuses
Pin indication Fuses
GBA
GLD
Specifications
Class:
Supplemental
Description:
Fast-acting, pin
indication fuse.
Dimensions:
1
4
” x 1
1
4
(6.6 x 31.7mm) 3AG.
Construction:
Fiber tube
Ratings:
Volts — See Agency Info below
Amps —
1
2
-15A
IR — See Agency Info below
Agency Information:
CE, Std. 248-
14, UL Listed, 0-5A/125Vac, 10,000
AIC, Guide JDYX, File E19180, UL
Recognized, 6A/125Vac, 1000AIC
8-15A/50Vac/dc, 300 AIC Guide
JDYX2, File E19180, CSA Certified:
0-5A/125Vac, 10,000 AIC Class
1422-01, File 53787.
Features and Benefits
• Type GBA has a “red” pin indicator
providing visual identification of failed
circuits, resulting in faster
troubleshooting (reduced circuit
downtime).
• Type GLD has an plated pin to
activate transmitting a electrical
signal to indicate the location of
opened circuits, resulting in reduced
downtime.
Typical Applications
• Control Circuits
• Electronic Circuits
GLD Catalog Numbers (Amps)
GLD-
1
2
GLD-
3
4
GLD-1
GLD-1 ⁄
2
1
MIC & MIN
Specifications
Class:
Supplemental
Description:
Fast-
acting, pin indication
fuse.
Dimensions:
13
32
” x 1
1
2
” (10.3 x
38.1mm) 5AG.
Construction:
Fiber tube
Ratings:
Volts — 250Vac (1-15A)
— 32V (20-30A)
Amps — 1-30A
IR — 35A (1A @250Vac)
— 100A (2-3A @250Vac)
— 200A (5-10A @250Vac)
— 750A (15A @250Vac)
— 10,000A (20-30A @32V)
— 35A (1A @250Vac)
Agency Information:
CE, Std. 248-14,
MIC—0-15A UL Listed, Guide JDYX,
File E19180, MIN—1-5A CSA Certified,
Class 1422-01, File 53787.
Features and Benefits
Type MIN has a “red” pin indicator
providing visual identification of failed
circuits, resulting in faster trouble
shooting (reduced circuit downtime).
Type MIC has silver-plated pin transmit-
ting an electrical signal indicating
location of a failed circuit, resulting in
faster troubleshooting (reduced circuit
downtime).
Typical Applications
Control Circuits
PLC Circuits
Electronic Circuits
MIC Catalog Numbers (Amps)
MIC-1
MIC-5
MIC-10
MIC-15
MIC-20
MIC-25
MIC-30
MIC-2
MIC-3
FNA
Specifications
Class:
Supplemental
Description:
Time-delay,
pin indication fuse.
Dimensions:
13
32
” x 1
1
2
(10.3 x 38.1mm).
Construction:
Fiber tube
Ratings:
Volts — 250Vac (
1
10
-
8
10
A)
— 125Vac (1-15A)
— 32V (20-30A)
Amps —
1
10
-30A
IR — 35A (
1
10
-
8
10
A @ 250Vac)
— 10,000A (
1
10
-15A @ 125Vac)
— 1000A (20-30A @ 32V)
Agency Information:
CE, Std. 248-
14, UL Listed
1
10
-
8
10
A, IR 35A@ 250V,
IR 10kA@ 125V , 1-15A, IR 10kA@
125V, Guide JDYX, File 19180, CSA
Certified, 0-
8
10
A/250V, 1-10A/125V,
Class 1422-01, File 53787.
Features and Benefits
• FNA has a pin indicator providing
visual identification of failed circuits,
resulting in reduced circuit downtime.
• Time-delay response allows close
sizing on control transformers and
relays
Typical Applications
• Control Circuits
• Electronic Circuits
Catalog Numbers (Amps)
FNA-
1
10
FNA-
1
8
FNA-
15
100
FNA-
2
10
FNA-
1
4
FNA-
3
10
FNA-
4
10
FNA-
1
2
FNA-
6
10
FNA-
3
4
FNA-
8
10
FNA-1
FNA-1
1
8
FNA-1
1
4
FNA-1
4
10
FNA-1
1
2
FNA-1
6
10
FNA-1
8
10
FNA-2
FNA-2
1
4
FNA-2
FNA-2
FNA-3
FNA-3
FNA-3
FNA-4
FNA-4
FNA-5
FNA-5
FNA-6
1
Low Voltage
Supplementary
Fuses
2
8
10
2
1
GLD-2
GLD-3
GLD-4
GLD-5
GLD-6
GLD-10
GLD-12
GLD-15
10
2
2
10
1
GBA Catalog Numbers (Amps)
GBA- ⁄
2
1
6
GBA-2
GBA-3
GBA-4
GBA-5
GBA-8
GBA-10
GBA-15
FNA-6
1
4
FNA-7
FNA-8
FNA-9
FNA-10
FNA-12*
FNA-15*
FNA-20*
FNA-25*
FNA-30
GBA-
3
4
GBA-1
GBA-1
1
2
MIC - (1-15)UL Listed 125Vac / IR = 10kA
*12-30A versions are dual-tube construction
MIN Catalog Numbers (Amps)
MIN-1
MIN-2
MIN-5
MIN-10
MIN-20
MIN-25N
Recommended fuse blocks/fuse
holders for
1
4
” x 1
1
4
” indicating fuses
Recommended signal block for
13
Recommended signal block for
13
32
” x 1
1
2
” indicating fuses
32
” x 1
1
2
” indicating fuses
• Page 41
Data Sheet: 2012
• Page 41
Data Sheet: 2047
• Page 41
Data Sheet: 2029
For product data sheets, visit www.cooperbussmann.com/products/datasheet.asp
47

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1346  1626  1762  1810  2657  28  33  36  37  54 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号