EEWORLDEEWORLDEEWORLD

Part Number

Search

RSB6HP03180315NN

Description
Barrier Strip Terminal Block, 20A, 1 Row(s), 1 Deck(s)
CategoryThe connector    terminals   
File Size146KB,4 Pages
ManufacturerThomas & Betts Corporation
Websitehttp://www.tnb.com/
Download Datasheet Parametric View All

RSB6HP03180315NN Overview

Barrier Strip Terminal Block, 20A, 1 Row(s), 1 Deck(s)

RSB6HP03180315NN Parametric

Parameter NameAttribute value
MakerThomas & Betts Corporation
Reach Compliance Codeunknown
ECCN codeEAR99
Fastening methodSCREW
Manufacturer's serial numberRSB6
Installation typeBOARD
Number of layers1
Rows1
Number of channels3
Rated current20 A
Rated voltage300 V
safety certificateUL
Terminal and terminal strip typesBARRIER STRIP TERMINAL BLOCK
Wire gauge14 AWG
Barrier Strips
Tri-Barriers
0.375" PITCH
SERIES RSB6
P
HYSICAL
P
ROPERTIES
H
OUSING
M
ATERIAL
:
Polypropylene
F
LAMMABILITY
:
UL94V-2
C
OLOR
:
Black
T
ERMINAL
T
ERMINALS
:
Brass, bright acid tin over copper plating
S
CREW
:
Steel w/Zinc + Chromate plating
C
LAMP
:
Steel w/Zinc + Chromate plating
RSB6RP##1102
Dimensions
M
ECHANICAL
P
ITCH
(T
ERMINAL
S
PACING
):
.375"
S
CREW
S
IZE
:
6-32
R
ECOMMENDED
PCB H
OLE
D
IA
.:
.062"
W
IRE
S
TRIP
L
ENGTH
:
.38"
R
ECOMMENDED
T
IGHTENING
T
ORQUE
:
9 in lbs.
R
ECOMMENDED
S
CREWDRIVERS
:
Stanley 1006-4,
Sears Craftsman 41581, Any #2 Phillips-Head
W
IRE
L
UG
W
IDTH
(M
AX
.):
8,1mm (.320")
CIRCUITS
(NOT
POSITIONS)
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
C1
IN.
L1*
IN.
C2
IN.
.75
L2*
IN.
1.22
1.59
1.97
2.34
2.72
3.09
3.47
3.84
3.84
4.59
4.97
5.34
5.72
6.09
6.47
6.84
7.22
7.59
7.97
8.34
8.72
9.09
9.47
9.84
10.22
10.59
10.97
11.34
11.72
12.09
12.47
12.84
13.22
13.59
13.97
14.34
.37
.75
1.13
1.50
1.88
2.25
2.63
3.00
3.37
3.75
4.13
4.50
4.88
5.25
5.63
6.00
6.38
6.75
7.13
7.50
7.88
8.25
8.63
9.00
9.38
9.75
10.13
10.50
10.88
11.25
11.63
12.00
12.38
12.75
13.13
.84
1.22
1.59
1.97
2.34
2.72
3.09
3.47
3.84
4.22
4.59
4.97
5.34
5.72
6.09
6.47
6.84
7.22
7.59
7.97
8.34
8.72
9.09
9.47
9.84
10.22
10.59
10.97
11.34
11.72
12.09
12.47
12.84
13.22
13.59
1.13
1.50
1.88
2.25
2.63
3.00
3.37
3.75
4.13
4.50
4.88
5.25
5.63
6.00
6.38
6.75
7.13
7.50
7.88
8.25
8.63
9.00
9.75
9.75
10.13
10.50
10.88
11.25
11.63
12.00
12.38
12.75
13.13
13.50
13.88
E
LECTRICAL
P
ROPERTIES
M
AXIMUM
C
URRENT
:
20A
O
PERATING
V
OLTAGE
:
300V
W
IRE
R
ANGE
:
(Clamp Screw) #12 max AWG
(Binding Head Screw) #14 max AWG
D
IELECTRIC
W
ITHSTAND
:
3500V
E
NVIRONMENTAL
P
ROPERTIES
O
PERATING
T
EMPERATURE
R
ANGE
:-60ºC
to +105ºC
(-76ºF to +221ºF)
Recommended PCB Hole Pattern
34
35
36
C
OMPUTING
RSB B
LOCK
L
ENGTHS
.
D
IRECT
M
OUNTING
Use C1 & L1 for VP, SP, RP, HP mounting
options
E
ND
P
OSITION
M
OUNTING
Use L2 & C2 for VM, SM, RM, VE,
SE, RE mounting options
LR49571
E60980
Thomas & Betts Electronics/OEM Division Tel: 901-252-7766 Fax: 901-252-1312
Dimensions shown are for reference only. Dimensions are in inches.
74
Detailed explanation of leakage current and contact current knowledge
[size=4] Leakage current refers to the current formed between mutually insulated metal parts or between live parts and grounded parts of equipment under the action of applied voltage, through the surr...
qwqwqw2088 Analogue and Mixed Signal
Help: 2812 cannot run after flashing
The 2812 runs correctly during simulation. When changing a .cmd file to burn, a warning appears for initializing RAM as follows:warning: Because this program contains initialized RAM data it may run s...
hezhengli Microcontroller MCU
EMI knowledge and Y capacitor design
This article first introduces the general knowledge about EMI and various buffer attraction circuits used in switching power supplies. Then it introduces the principles of common mode and differential...
lixiaohai8211 Discrete Device
2812 locked
2812 is locked, how to unlock it, can anyone tell me, I will be very grateful......
wzp2007 DSP and ARM Processors
MSP430 Usage
Is the MSP430 series widely used in the market? I don't think many people around me use it, so I want to know. Is there anyone who knows the market situation? Thank you!...
ztd321 Microcontroller MCU
Office Feng Shui taboo: sitting with your back to the door is the most powerful light evil
1 The fourth taboo of office Feng Shui is that there is no mountain behind the seat. From the perspective of Feng Shui, 2. Taboo: Sitting with your back to the door. If the desk is placed near the doo...
cn_mylove Talking

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1905  1979  755  1044  740  39  40  16  22  15 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号