MIL-PRF-39006 Series
Military Conventional Wet Tantalum
This data sheet contains the MIL-PRF-39006 ratings to which AVX is a
qualified approved supplier. This will be continually updated as the
qualification expands. For COTS-Plus equivalent ratings please refer to the
TWC data sheet located on the website.
This design is an axial leaded tubular case. It includes a welded tantalum can
and header assembly that provides a hermetic seal to withstand harsh
environments. The 1000 hour failure rates of 1%, 0.1% and 0.01%
correspond to “M”, “P”, and “R” respectively.
For details on testing conditions please refer to MIL-PRF-39006.
Currently qualified M39006 ratings include:
/22 “M” Level: 25V to 100V: dashes -0081 to -0200
/25 “M” Level: 25V to 100V: dashes -0033 to -0080
/30 “M” Level: 25V to 100V: dashes -0081 to -0200
/31 “M” Level: 25V to 100V: dashes -0033 to -0080
OUTLINE DIMENSIONS
E
L
E
W
F
Terminal welded
to case (T)
D
-
+
F 6.35 (0.250)
W 0.64 +0.05
(.025 +.002)
T 2.380 (.094)
Case
CASE DIMENSIONS:
millimeters (inches)
DSCC
Case
Size
T1
T2
T3
T4
AVX
Case
Size
A
B
D
E
L
+0.79 (0.031)
-0.41 (0.016)
11.51 (0.453)
16.28 (0.641)
19.46 (0.766)
26.97 (1.062)
D
Basic Case
±0.41 (0.016)
4.78 (0.188)
7.14 (0.281)
9.52 (0.375)
9.52 (0.375)
D
Insulated Case
Max
5.56 (0.219)
7.92 (0.312)
10.31 (0.406)
10.31 (0.406)
E
±6.35 (0.250)
38.10
57.15
57.15
57.15
(1.500)
(2.250)
(2.250)
(2.250)
VOLTAGE RATINGS
(Operating Temperature -55ºC to 125ºC)
Voltage (DC)
Rated Voltage: (V
r
)
Derated Voltage: (V
c
)
Surge Voltage: (V
s
)
85ºC
125ºC
85ºC
6
4
6.9
8
5
9.2
10
6
11.5
15
10
17.3
25
15
28.8
30
20
34.5
50
30
57.5
60
40
69
75
50
86.3
100
65
115
125
85
144
51
MIL-PRF-39006 Series
Military Conventional Wet Tantalum
HOW TO ORDER MILITARY M39006 PART NUMBER:
M39009
Type / Military
Designator
\22
Specification
Sheet
Number
–0081
Dash
Number
–
Not RoHS Compliant
*H = High Vibration
(When Specified)
*High vibration qualified parts are currently under development. Please contact the factory for additional details and availability.
RIPPLE CURRENT MULTIPLIERS
Frequency of
Applied
Ripple Current
Ambient Still Air
Temperature (ºC)
% of
100%
85ºC
90%
Rated
80%
Peak
70%
Voltage 66-2/3%
Frequency of
Applied
Ripple Current
Ambient Still Air
Temperature (ºC)
% of
100%
85ºC
90%
Rated
80%
Peak
70%
Voltage 66-2/3%
120Hz
≤55
0.60
0.60
0.60
0.60
0.60
85
0.39
0.46
0.52
0.58
0.60
105
–
–
0.35
0.44
0.46
125
–
–
–
–
0.27
≤55
0.71
0.71
0.71
0.71
0.71
vs. Frequency, temperature and applied voltage
1/ 2/
800Hz
85
105
–
–
0.42
0.52
0.55
125
–
_
–
–
0.32
≤55
0.72
0.72
0.72
0.72
0.72
85
0.45
0.55
0.62
0.70
0.72
1kHz
105
–
–
0.42
0.52
0.55
125
–
–
–
–
0.32
0.43
0.55
0.62
0.69
0.71
10kHz
≤55
0.88
0.88
0.88
0.88
0.88
85
0.55
0.67
0.76
0.85
0.88
105
–
–
0.52
0.64
0.68
125
–
–
–
–
0.40
≤55
1.00
1.00
1.00
1.00
1.00
85
40kHz
105
–
–
0.59
0.73
0.77
125
–
_
–
–
0.45
≤55
1.10
1.10
1.10
1.10
1.10
100kHz
85
0.69
0.85
0.96
1.07
1.10
105
–
–
0.65
0.80
0.85
125
–
–
–
–
0.50
0.63
0.77
0.87
0.97
1.00
1/ At 125ºC the rated voltage of the capacitors decreases to 66 2/3 of the 85ºC rated voltage.
2/ The peak of the applied ac ripple voltage plus the applied dc voltage must not exceed the dc voltage rating of the capacitors.
52
MIL-PRF-39006 Series
Military Conventional Wet Tantalum
M39006 /22 RATINGS AND DASH NUMBER REFERENCE
M39006/22
“M” Level
Reliability
Dash
Numbers
–0081
–0082
–0083
–0084
–0085
–0086
–0087
–0088
–0089
–0090
–0091
–0092
–0093
–0094
–0095
–0096
–0097
–0098
–0099
–0100
–0101
–0102
–0103
–0104
–0105
–0106
–0107
–0108
–0109
–0110
–0111
–0112
–0113
–0114
–0115
–0116
–0117
–0118
–0119
–0120
–0121
–0122
–0123
–0124
–0125
–0126
–0127
–0128
–0129
–0130
–0131
–0132
–0133
–0134
–0135
–0136
–0137
–0138
–0139
–0140
–0141
–0142
–0143
–0144
–0145
–0146
Tolerance
(%)
20
10
5
20
10
5
20
10
5
20
10
5
20
10
5
20
10
5
20
10
20
10
5
20
10
5
20
10
5
20
10
5
20
10
5
20
10
5
20
10
20
10
5
20
10
5
20
10
5
20
10
5
20
10
5
20
10
5
20
10
20
10
5
20
10
5
Cap
(uF)
25°C
at
120Hz
10
DC Rated
Voltage
(V)
at
85ºC
25
DC Leakage (uA)
+25ºC
+85ºC
&
125ºC
2
DF
max
(%)
ESR
max
(Ohms)
at
120Hz
5.31
Impedance
max
(Ohms)
-55ºC at
120Hz
220
Maximum Capacitance
Change (%)
-55ºC
-16
+85ºC
8
+125ºC
9
AC Ripple
(mA rms)
85ºC
at
40kHz
715
Case
Size
Standard
1
4
T1
22
25
1
2
6.6
3.98
140
-20
10.5
12
825
T1
50
25
1
2
11
2.92
70
-28
13
15
1130
T2
100
25
1
10
15
1.99
50
-28
13
15
1435
T2
120
25
2
6
21
2.32
38
-32
13
15
1450
T3
180
350
8
25
25
30
2
7
1
18
28
2
26
35
4
1.92
1.33
6.64
32
24
275
-48
-70
-16
13
25
8
15
25
12
1525
1970
640
T3
T4
T1
15
30
1
2
5
4.42
175
-20
10.5
12
780
T1
40
30
1
5
10
3.32
65
-24
10.5
12
1120
T2
68
30
1
8
13
2.54
60
-24
13
15
1285
T2
100
30
2
12
17
2.26
40
-28
10.5
12
1450
T3
150
300
5
30
30
50
2
8
1
18
32
2
23
31
3
2.03
1.37
7.96
35
25
400
-48
-60
-16
13
25
5
15
25
6
1525
1950
580
T3
T4
T1
10
50
1
2
4
5.31
250
-24
8
9
715
T1
25
50
1
5
8
4.25
95
-20
10.5
12
1005
T2
47
50
1
9
11
3.11
70
-28
13
15
1155
T2
60
50
2
12
12
2.65
45
-16
10.5
12
1335
T3
82
160
4
50
50
60
2
8
1
16
32
2
15
17
2.8
2.43
1.41
9.29
45
27
550
-32
-50
-16
13
25
5
15
25
6
1400
1900
525
T3
T4
T1
8.2
60
1
2
4
6.47
275
-24
8
9
625
T1
All technical data relates to an ambient temperature of +25ºC. Capacitance and DF are measured at 120Hz, 0.5RMS with DC bias of 2.2V.
DCL is measured at rated voltage after 5 minutes.
53
MIL-PRF-39006 Series
Military Conventional Wet Tantalum
M39006/22
“M” Level
Reliability
Dash
Numbers
–0147
–0148
–0149
–0150
–0151
–0152
–0153
–0154
–0155
–0156
–0157
–0158
–0159
–0160
–0161
–0162
–0163
–0164
–0165
–0166
–0167
–0168
–0169
–0170
–0171
–0172
–0173
–0174
–0175
–0176
–0177
–0178
–0179
–0180
–0181
–0182
–0183
–0184
–0185
–0186
–0187
–0188
–0189
–0190
–0191
–0192
–0193
–0194
–0195
–0196
–0197
–0198
–0199
–0200
Tolerance
(%)
20
10
5
20
10
5
20
10
5
20
10
5
20
10
20
10
5
20
10
5
20
10
5
20
10
5
20
10
5
20
10
5
20
10
±20
±10
±5
±20
±10
±5
±20
±10
±5
±20
±10
±5
±20
±10
±5
±20
±10
±5
±20
±10
Cap
(uF)
25°C
at
120Hz
20
DC Rated
Voltage
(V)
at
85C
60
DC Leakage (uA)
+25ºC
+85ºC
&
125ºC
5
DF
max
(%)
ESR
max
(Ohms)
at
120Hz
4.64
Impedance
max
(Ohms)
-55ºC at
120Hz
105
Maximum Capacitance
Change (%)
-55ºC
-16
+85ºC
10.5
+125ºC
12
AC Ripple
(mA rms)
85ºC
at
40kHz
930
Case
Size
Standard
1
7
T2
39
60
1
9
10
3.4
90
-28
10.5
12
1110
T2
50
60
2
12
10
2.65
50
-16
10.5
12
1330
T3
68
140
3.5
60
60
75
2
8
1
16
32
2
13
16
2.5
2.54
1.52
9.48
50
28
650
-32
-40
-16
10.5
20
5
12
20
6
1365
1850
525
T3
T4
T1
6.8
75
1
2
3.5
6.83
300
-20
8
9
610
T1
15
75
1
5
6
5.31
150
-16
8
9
890
T2
33
75
1
10
10
4.02
90
-24
10.5
15
1000
T2
40
75
2
12
9
2.99
60
-16
10.5
12
1250
T3
56
110
2.5
75
75
100
2
9
1
17
36
2
11
12
2
2.61
1.45
10.62
60
29
950
-28
-35
-16
10.5
20
7
15
20
8
1335
1850
505
T3
T4
T1
4.7
100
1
2
3
8.47
500
-16
7
8
565
T1
11
100
1
4
5
6.03
200
-16
8
8
835
T2
22
100
1
9
7.5
4.52
100
-16
8
8
965
T2
30
100
2
12
7
3.1
80
-16
8
8
1240
T3
43
86
100
100
2
9
17
36
8.5
10
2.62
1.54
70
30
-20
-25
8
15
8
15
1335
1800
T3
T4
All technical data relates to an ambient temperature of +25ºC. Capacitance and DF are measured at 120Hz, 0.5RMS with DC bias of 2.2V.
DCL is measured at rated voltage after 5 minutes.
54
MIL-PRF-39006 Series
Military Conventional Wet Tantalum
M39006 /25 RATINGS AND DASH NUMBER REFERENCE
M39006/25
“M” Level
Reliability
Dash
Numbers
–0033
–0034
–0035
–0036
–0037
–0038
–0039
–0040
–0041
–0042
–0043
–0044
–0045
–0046
–0047
–0048
–0049
–0050
–0051
–0052
–0053
–0054
–0055
–0056
–0057
–0058
–0059
–0060
–0061
–0062
–0063
–0064
–0065
–0066
–0067
–0068
–0069
–0070
–0071
–0072
–0073
–0074
–0075
–0076
–0077
–0078
–0079
–0080
Tolerance
(%)
±20
±10
±20
±10
±20
±10
±20
±10
±20
±10
±20
±10
±20
±10
±20
±10
±20
±10
±20
±10
±20
±10
±20
±10
±20
±10
±20
±10
±20
±10
±20
±10
±20
±10
±20
±10
±20
±10
±20
±10
±20
±10
±20
±10
±20
±10
±20
±10
Cap
(uF)
25°C
at
120Hz
68
270
560
680
56
220
470
560
33
120
270
330
27
100
220
270
22
82
180
220
10
39
68
120
DC Rated
Voltage
(V)
at
85ºC
25
25
25
25
30
30
30
30
50
50
50
50
60
60
60
60
75
75
75
75
100
100
100
100
DC Leakage (uA)
+25ºC
2
3
7
8
2
3
8
9
2
4
8
9
3
4
8
9
3
4
9
10
3
5
10
12
+85ºC
&
125ºC
9
16
28
32
9
16
32
36
9
24
32
36
12
20
32
36
12
24
36
40
12
24
40
48
DF
max
(%)
22
55
76
63
22
42
64
55
12.3
22.5
37
38
10.2
19
30
27
8.5
15.2
24.4
37
4.5
10.4
11.3
25
ESR
max
(Ohms)
at
120Hz
4.29
2.7
1.8
1.23
5.21
2.53
1.81
1.3
4.95
2.49
1.82
1.53
5.01
2.52
1.81
1.33
5.13
2.46
2.23
1.8
5.97
3.54
2.21
2.76
Impedance
max
(Ohms)
-55ºC at
120Hz
90
33
24
19
100
36
25
20
135
49
29
22
144
54
29
23
157
63
30
24
200
80
40
30
Maximum Capacitance
Change (%)
-55ºC
-40
-62
-72
-72
-38
-60
-65
-65
-29
-42
-46
-46
-24
-36
-40
-45
-19
-30
-35
-40
-17
-20
-30
-35
+85ºC
12
13
20
25
12
13
20
25
10
12
20
25
10
12
16
20
10
12
16
20
10
12
14
15
+125ºC
15
16
25
30
15
16
25
30
12
15
25
30
12
15
20
25
12
15
20
25
12
15
16
17
AC Ripple
(mA rms)
85ºC
at
40kHz
850
1400
1750
2100
800
1200
1500
2000
700
1200
1450
1900
700
1100
1400
1850
600
1000
1300
1800
800
1300
1600
2000
Case
Size
Standard
T1
T2
T3
T4
T1
T2
T3
T4
T1
T2
T3
T4
T1
T2
T3
T4
T1
T2
T3
T4
T1
T2
T3
T4
All technical data relates to an ambient temperature of +25ºC. Capacitance and DF are measured at 120Hz, 0.5RMS with DC bias of 2.2V.
DCL is measured at rated voltage after 5 minutes.
55