805-004-01NF19-85SB

Description
85 CONTACT(S), ALUMINUM ALLOY, FEMALE, CIRCULAR CONNECTOR, CRIMP, RECEPTACLE
CategoryThe connector    The connector   
File Size220KB,4 Pages
ManufacturerGlenair
Websitehttp://www.glenair.com/
Download Datasheet Parametric View All

805-004-01NF19-85SB Overview

85 CONTACT(S), ALUMINUM ALLOY, FEMALE, CIRCULAR CONNECTOR, CRIMP, RECEPTACLE

805-004-01NF19-85SB Parametric

Parameter NameAttribute value
Is it lead-free?Contains lead
Is it Rohs certified?incompatible
MakerGlenair
Reach Compliance Codenot_compliant
Other featuresPOLARIZED
Back shell typeSOLID
Body/casing typeRECEPTACLE
Connector typeCIRCULAR CONNECTOR
Contact to complete cooperationGOLD OVER NICKEL
Contact completed and terminatedGold (Au) - with Nickel (Ni) barrier
Contact point genderFEMALE
Contact materialBERYLLIUM COPPER
Coupling typeTHREADED
DIN complianceNO
empty shellNO
Filter functionNO
IEC complianceNO
JESD-609 codee4
MIL complianceNO
Mixed contactsNO
Installation typeCABLE
OptionsGENERAL PURPOSE
Shell surfaceCADMIUM WITH CHROMATE PLATED
Shell materialALUMINUM ALLOY
Housing size19
Termination typeCRIMP
Total number of contacts85
A
B
C
D
E
F
G
H
J
K
L
M
© 2007 Glenair, Inc.
Series 805
Series 805 “Mighty Mouse”
Triple-Start
Series 805 Receptacles
Three Shell Mounting Options:
Jam nut with o-ring for rear panel
mounting, square flange for front
or rear panel mounting, or in-line
receptacles for free-hanging cables.
Two Shell Styles:
Choose
integral
band platform
for direct attachment
of a cable shield. Install a boot,
or overmold a boot over the band
platform.
Gold-Plated Crimp Contacts
are held in place with beryllium
copper retention clips. Contacts are
removable.
Series 805 Triple-Start
Jam Nut Connector
An
accessory thread
is available
for attaching strain reliefs and
backshells.
HOW TO ORDER
Sample Part Number
80 5- 0 0 4
Series
-02
Shell Style
NF
Shell Material /
Finish
C
Aluminum / Black
Anodize
9-10
Shell Size- Insert
Arrangement
1 #16 Contact
4 #23 Contacts
7 #23 Contacts
1 #12 Contact
10 #23 Contacts
13 #23 Contacts
4 #16 Contacts
19 #23 Contacts
26 #23 Contacts
2 #12 Contacts
15-37
37 #23 Contacts
18-55
55 #23 Contacts
19-85
85 #23 Contacts
Size #23 contacts are
supplied with connectors.
Other contact sizes are
ordered separately.
P
Contact Type
Standard #23 contacts
accept #22 through
#28 AWG wire. Use the
following contact codes
to specify these contacts:
A
Shell Key
Position
A
Position A
(Normal)
M
-01
805-003
Receptacle with
Banding Platform
In-Line
Aluminum / Electroless
Nickel
NF
Aluminum / Cadmium
with Olive Drab
Chromate
8-1
8-4
8-7
9-1
9-10
10-13
11-4
11-19
12-26
15-2
B
Position B
P
Pin
C
Position C
S
Socket
Special contacts for
#26 to #30 AWG are
also available. Use the
following contact codes
to specify these contacts:
D
Position D
ZN
-02
Square Flange
Aluminum / Zinc-
Nickel with Olive Drab
Chromate
805-004
Receptacle with
Accessory Thread
-07
Jam Nut for Rear
Panel Mounting
ZNU
Aluminum / Zinc-Nickel
with Black Chromate
G
Pin
Z1
Stainless Steel /
Passivated
H
Socket
CAGE Code 06324
Printed in U.S.A.
GLENAIR, INC. • 1211 AIR WAY • GLENDALE, CA 91201-2497 • 818-247-6000 • FAX 818-500-9912
www.glenair.com
H-6
Rev. 05-APR-2007
E-Mail: sales@glenair.com
What is an ISP?
The program involves issp, which seems to be a single pin, through which the flash can be flashed. Which hero can introduce this thing to me? Thank you...
cekong Embedded System
while loop switching tasks
I created two tasks, both of which are while loops. Assume that the higher priority task is A and the lower priority task is B. The system starts running in task A. When it runs OSTimeDly(100), the ta...
中华小逗逼 Real-time operating system RTOS
I fell in love with msp430 unknowingly.
When I first started working, I went to the electronics market to buy something. A gentleman asked me if I knew 430. At that time, I had never heard of it, because I only knew 51, so I didn't care. La...
wzjhuohua Microcontroller MCU
A review of the experiments and countermeasures of electrical fast pulse groups
A review of the experiments and countermeasures of electrical fast pulse groups【Source: China PCB Technology Network】【Author:】【Time: 2005-12-29 8:57:11】【Click: 513】1. Test waveform The purpose of the ...
fighting Energy Infrastructure?
ADC Experiment of LM3S328
I asked about the ADC experiment earlier, but I never got an answer. Now I finally made it and I'd like to share it with you. The experimental result is: the light will be on when the sampling voltage...
shmily53 Microcontroller MCU
Help me, everyone.
Why can't I see the NANDFLASH disk in the CE os I configured myself? The strange thing is that the OS I burned into the NAND can only run at the beginning, but it can't run after shutting down and res...
xiaoxiao818 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2779  2508  1715  1247  2376  56  51  35  26  48 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号