A38115L3

Description
Barrier Strip Terminal Block, 30A, 1 Row(s), 1 Deck(s)
CategoryThe connector    terminals   
File Size239KB,2 Pages
ManufacturerEaton
Download Datasheet Parametric View All

A38115L3 Overview

Barrier Strip Terminal Block, 30A, 1 Row(s), 1 Deck(s)

A38115L3 Parametric

Parameter NameAttribute value
MakerEaton
Reach Compliance Codecompliant
ECCN codeEAR99
Other features94V-0
Fastening methodSCREW
Manufacturer's serial numberA38
Number of layers1
Rows1
Number of channels15
Rated current30 A
Rated voltage600 V
safety certificateUL; CSA; CE
Terminal and terminal strip typesBARRIER STRIP TERMINAL BLOCK
Wire gauge10 AWG
INDEX
Series A38 / B38
Single Row Terminal Blocks
SPECIFICATIONS
Rating:
A38: 30A, 600V
B38: 50A, 600V
Center Spacing:
.437” (11.10 mm)
Wire Size:
#10-22 AWG CU
Screw Size:
#8-32 Zinc Plated Steel
Torque Rating:
A38: 9 in-lb; B38: 15 in-lb
Distance Between Barriers:
.378” (9.60mm)
Operating Temperature:
221°F (105°C)
Molded Material:
Black, UL Rated 94VO Thermoplastic
Breakdown Voltage:
5000V rms
Recommended PCB Hole Diameter (A38):
.076” (1.93mm)
Approvals:
UL E62622; CSA LR15364; CE Certified
TABLE A
MOUNTING
ENDS ONLY
Poles
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
B
Mount Ctrs.
1.31
1.75
2.19
2.62
3.06
3.50
3.93
4.37
4.81
5.24
5.68
6.12
6.56
6.99
7.43
“A”
Dim. Length
1.67
2.10
2.54
2.98
3.41
3.85
4.29
4.72
5.16
5.60
6.04
6.47
6.91
7.35
7.78
BARRIER
ENDS ONLY
“A”
Dim. Length
0.93
1.37
1.81
4.05
2.68
3.12
3.56
3.99
4.43
4.87
5.30
5.74
6.18
6.61
7.05
A382208
B381404
Series A38
"A" DIM.
"B" DIM.
HOLE SIZE
.20
(5.0)
11.10
(.437)
.80
(20.4)
* Dimensions in inches. To convert to millimeters, multiply by 25.4.
.28
(7.0)
Series B38
"A" DIM.
.437
(11.10)
.65
(16.4)
.21
(5.2)
.25
(6.4)
Cooper Bussmann
l
7300 W. Wilson Ave
l
Chicago, IL 60656-4708
l
Fax: 708-867-2211
l
Phone: 708-867-4600
Website: http://www.busscc.com
19
About implementing Flash player on WM5 using Adobe's controls and libraries
I posted before, but I can't reply to it. It's very urgent, so I ask again [Is there anyone who has transplanted FLASH player to WINCE? ] http://topic.eeworld.net/u/20070702/14/9d45b749-db60-4df0-8c28...
fjqiuh Embedded System
The motor drive circuit built with MOS tubes gets hot when the load is slightly heavy.
[img]http://imgsrc.baidu.com/forum/w%3D580%3Bcp%3Dtieba%2C10%2C447%3Bap%3D%B5%E7%D7%D3%C9%E8%BC%C6%B0%C9%2C90%2C455/sign=d0049bdf810a19d8cb03840d03c1e1fb/8ad4b31c8701a18b9b6dd0219f2f07082938fede.jpg[/...
rockyyangyang Motor Drive Control(Motor Control)
What is FM24C04 used for?
I would like to ask everyone, can multiple FM24C04 be used together? How to use them specifically? Thank you very much! Hehe...
王者风范 Integrated technical exchanges
.NetMicro Framework ported on STM32 (Cortem-M3) platform
1. [.Net Micro Framework PortingKit - 01] Preliminary transplantation: Environment construction [url=http://blog.eeworld.net/yefanqiu/archive/2010/01/01/5117554.aspx]http://blog.eeworld.net/yefanqiu/a...
qing_yx stm32/stm8
Question about the interrupt priority of stm32 systick?
Where can I set the interrupt priority of the systick of stm32?What is the default priority? Why can't I find the setting of the interrupt priority of systick? ?Expert advice...
wzy19970701 stm32/stm8
wince deployment issues
I deployed it to a wince board via vs2005 but my newly created folder disappeared after reboot. Now I have an sd memory card. How can I write the data to the card and have it run automatically when th...
junweisteven Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2451  1492  522  843  1543  50  31  11  17  32 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号