ELECTRICAL SPECIFICATION @ Tamb = 25°C
PART
NUMBER
UNI-POLAR
DEVICE
CODE
REVERSE
STANDOFF
VOLTAGE
V
R
(Volts)
MIN
P6SMBJ 6V8 / P6SMBJ 6V8C
P6SMBJ 6V8A / P6SMBJ 6V8CA
P6SMBJ 7V5 / P6SMBJ 7V5C
P6SMBJ 7V5A / P6SMBJ 7V5CA
P6SMBJ 8V2 / P6SMBJ 8V2C
P6SMBJ 8V2A / P6SMBJ 8V2CA
P6SMBJ 9V1 / P6SMBJ 9V1C
P6SMBJ 9V1A / P6SMBJ 9V1CA
P6SMBJ 10 / P6SMBJ 10C
P6SMBJ 10A / P6SMBJ 10CA
P6SMBJ 11 / P6SMBJ 11C
P6SMBJ 11A / P6SMBJ 11CA
P6SMBJ 12 / P6SMBJ 12C
P6SMBJ 12A / P6SMBJ 12CA
P6SMBJ 13 / P6SMBJ 13C
P6SMBJ 13A / P6SMBJ 13CA
P6SMBJ 15 / P6SMBJ 15C
P6SMBJ 15A / P6SMBJ 15CA
P6SMBJ 16 / P6SMBJ 16C
P6SMBJ 16A / P6SMBJ 16CA
P6SMBJ 18 / P6SMBJ 18C
P6SMBJ 18A / P6SMBJ 18CA
P6SMBJ 20 / P6SMBJ 20C
P6SMBJ 20A / P6SMBJ 20CA
P6SMBJ 22 / P6SMBJ 22C
P6SMBJ 22A / P6SMBJ 22CA
P6SMBJ 24 / P6SMBJ 24C
P6SMBJ 24A / P6SMBJ 24CA
P6SMBJ 27 / P6SMBJ 27C
P6SMBJ 27A / P6SMBJ 27CA
P6SMBJ 30 / P6SMBJ 30C
P6SMBJ 30A / P6SMBJ 30CA
P6SMBJ 33 / P6SMBJ 33C
P6SMBJ 33A / P6SMBJ 33CA
P6SMBJ 36 / P6SMBJ 36C
P6SMBJ 36A / P6SMBJ 36CA
P6SMBJ 39 / P6SMBJ 39C
P6SMBJ 39A / P6SMBJ 39CA
P6SMBJ 43 / P6SMBJ 43C
P6SMBJ 43A / P6SMBJ 43CA
P6SMBJ 47 / P6SMBJ 47C
P6SMBJ 47A / P6SMBJ 47CA
P6SMBJ 51 / P6SMBJ 51C
P6SMBJ 51A / P6SMBJ 51CA
Notes:
1. Testing is performed @ 25˚
2. Bv is measured using a pulse of 20 milliseconds or less
3. V
F
, for uni-diectional devices, is measured using a 300 microsecond square wave pulse @
I
T
= 50A
4.
I
R
is doubled for Bi-directional devices only with V
R
equal or less than 10 volts
6V8 / 6V8C
6V8A /6V8CA
7V5 / 7V5C
7V5A / 7V5CA
8V2 / 8V2C
8V2A / 8V2CA
9V1 / 9V1C
9V1A / 9V1CA
10 / 10C
10A / 10CA
11 / 11C
11A / 11CA
12 / 12C
12A / 12CA
13 / 13C
13A / 13CA
15 / 15C
15A / 15CA
16 / 16C
16A / 16CA
18 / 18C
18A / 18CA
20 / 20C
20A / 20CA
22 / 22C
22A / 22CA
24 / 24C
24A / 24CA
27 / 27C
27A / 27CA
30 / 30C
30A / 30CA
30 / 33C
33A / 33CA
36 / 36C
36A / 36CA
39 / 39C
39A / 39CA
43 / 43C
43A / 43CA
47 / 47C
47A / 47CA
51 / 51C
51A / 51CA
5.50
5.80
6.05
6.40
6.63
7.02
7.37
7.78
8.10
8.55
8.92
9.40
9.72
10.2
10.5
11.1
12.1
12.8
12.9
13.6
14.5
15.3
16.2
17.1
17.8
18.8
19.4
20.5
21.8
23.1
24.3
25.6
26.8
28.2
29.1
30.8
31.6
33.3
34.8
36.8
38.1
40.2
41.3
43.6
6.12
6.45
6.75
7.13
7.38
7.79
8.19
8.65
9.00
9.50
9.90
10.50
10.80
11.40
11.70
12.40
13.50
14.30
14.40
15.20
16.20
17.10
18.00
19.00
19.80
20.90
21.60
22.80
24.30
25.70
27.00
28.50
29.70
31.40
32.40
34.20
35.10
37.10
38.70
40.90
42.30
44.70
45.90
48.50
BREAKDOWN
VOLTAGE
V
BR
(Volts) @
I
T
MAX
7.48
7.14
8.25
7.88
9.02
8.61
10.00
9.55
11.00
10.50
12.10
11.60
13.20
12.60
14.30
13.70
16.50
15.80
17.60
16.80
19.80
18.90
22.00
21.00
24.20
23.10
26.40
25.20
29.70
28.40
33.0
31.50
36.30
34.70
39.60
37.80
42.90
41.00
47.30
45.20
51.70
49.40
56.10
53.60
10.0
10.0
10.0
10.0
10.0
10.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1000.0 (4)
1000.0 (4)
500.0 (4)
500.0 (4)
200.0 (4)
200.0 (4)
50.0 (4)
50.0 (4)
10.0 (4)
10.0 (4)
5.0 (4)
5.0 (4)
5.0 (4)
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
MAXIMUM
REVERSE
LEAKAGE
I
R
@ V
R
(µA)
MAXIMUM
CLAMPING
VOLTAGE
V
C
@
I
PP
(Volts)
(mA)
10.8
10.5
11.7
11.3
12.5
12.1
13.8
13.4
15.0
14.5
16.2
15.6
17.3
16.7
19.0
18.2
22.0
21.2
23.5
22.5
26.1
25.2
29.1
27.7
31.9
30.6
34.7
33.2
39.1
37.5
43.5
41.4
47.7
45.7
52.0
49.9
56.4
53.9
61.9
59.3
67.8
64.8
73.5
70.1
MAXIMUM MAXIMUM
PEAK PULSE FORWARD
CURRENT
VOLTAGE
I
PP
@ V
C
(V
F
) @
I
T
(A)
(Volts)
56.0
57.0
51.0
53.0
48.0
50.0
44.0
45.0
40.0
41.0
37.0
38.0
35.0
36.0
32.0
33.0
27.0
28.0
26.0
27.0
23.0
24.0
21.0
22.0
19.0
20.0
17.0
18.0
15.0
16.0
14.0
14.4
12.6
13.2
11.6
12.0
10.5
11.2
9.6
10.1
8.9
9.3
8.2
8.6
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
All products are sold to the commercial specifications shown, for any additional reliability testing or extended parameters, please consult the factory.
contact semitron on: telephone:
+44 (0)1793 724000
fax:
+44 (0)1793 720401
9
ELECTRICAL SPECIFICATION @ Tamb = 25°C
PART
NUMBER
UNI-POLAR
DEVICE
CODE
REVERSE
STANDOFF
VOLTAGE
V
R
(Volts)
MIN
P6SMBJ 56 / P6SMBJ 56C
P6SMBJ 56A / P6SMBJ 56CA
P6SMBJ 62 / P6SMBJ 62C
P6SMBJ 62A / P6SMBJ 62CA
P6SMBJ 68 / P6SMBJ 68C
P6SMBJ 68A / P6SMBJ 68CA
P6SMBJ 75/ P6SMBJ 75C
P6SMBJ 75A / P6SMBJ 75CA
P6SMBJ 82 / P6SMBJ 82C
P6SMBJ 82A / P6SMBJ 82CA
P6SMBJ 91 / P6SMBJ 91C
P6SMBJ 91A / P6SMBJ 91CA
P6SMBJ 100 / P6SMBJ 100C
P6SMBJ 100A / P6SMBJ 100CA
P6SMBJ 110 / P6SMBJ 110C
P6SMBJ 110A / P6SMBJ 110CA
P6SMBJ 120 / P6SMBJ 120C
P6SMBJ 120A / P6SMBJ 120CA
P6SMBJ 130 / P6SMBJ 130C
P6SMBJ 130A / P6SMBJ 130CA
P6SMBJ 150 / P6SMBJ 150C
P6SMBJ 150A / P6SMBJ 150CA
P6SMBJ 160 / P6SMBJ 160C
P6SMBJ 160A / P6SMBJ 160CA
P6SMBJ 170 / P6SMBJ 170C
P6SMBJ 170A / P6SMBJ 170CA
P6SMBJ 180 / P6SMBJ 180C
P6SMBJ 180A / P6SMBJ 180CA
P6SMBJ 200 / P6SMBJ 200C
P6SMBJ 200A / P6SMBJ 200CA
P6SMBJ 220 / P6SMBJ 220C
P6SMBJ 220A / P6SMBJ 220CA
Notes:
1. Testing is performed @ 25˚
2. Bv is measured using a pulse of 20 milliseconds or less
3. V
F
, for uni-diectional devices, is measured using a 300 microsecond square wave pulse @
I
T
= 50A
4.
I
R
is doubled for Bi-directional devices only with V
R
equal or less than 10 volts
56 / 56C
56A / 56CA
62 / 62C
62A / 62CA
68 / 68C
68A / 68CA
75 / 75C
75A / 75CA
82 / 82C
82A / 82CA
91 / 91C
91A / 91CA
100 / 100C
100A / 100CA
110 / 110C
110A / 110CA
120 / 120C
120A / 120CA
130 / 130C
130A / 130CA
150 / 150C
150A / 150CA
160 / 160C
160A / 160CA
170 / 170C
170A / 170CA
180 / 180C
180A / 180CA
200 / 200C
200A / 200CA
220 / 220C
220A / 220CA
45.4
47.8
50.2
53.0
55.1
58.1
60.7
64.1
66.4
70.1
73.7
77.8
81.0
85.5
89.2
94.0
97.2
102.0
105.0
111.0
121.0
128.0
130.0
136.0
138.0
145.0
146.0
154.0
162.0
171.0
175.0
185.0
50.40
53.20
55.80
58.90
61.20
64.60
67.50
71.30
73.80
77.90
81.90
86.50
90.00
95.00
99.00
105.00
108.00
114.00
117.00
124.00
135.00
143.00
144.00
152.00
153.00
162.00
162.00
171.00
180.00
190.00
198.00
209.00
BREAKDOWN
VOLTAGE
V
BR
(Volts) @
I
T
MAX
61.60
58.80
68.20
65.10
74.80
71.40
82.50
78.80
90.20
86.10
100.00
95.50
110.00
105.00
121.00
116.00
132.00
126.00
143.00
137.00
165.00
158.00
176.00
168.00
187.00
179.00
198.00
189.00
220.00
210.00
242.00
231.00
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
1.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
5.0
MAXIMUM
REVERSE
LEAKAGE
I
R
@ V
R
(µA)
MAXIMUM
CLAMPING
VOLTAGE
V
C
@
I
PP
(Volts)
(mA)
80.5
77.0
89.0
85.0
98.0
92.0
108.0
103.0
118.0
113.0
131.0
125.0
144.0
137.0
158.0
152.0
173.0
165.0
187.0
179.0
215.0
207.0
230.0
219.0
244.0
234.0
258.0
246.0
287.0
274.0
344.0
328.0
MAXIMUM MAXIMUM
PEAK PULSE FORWARD
CURRENT
VOLTAGE
I
PP
@ V
C
(V
F
) @
I
T
(A)
(Volts)
7.4
7.8
6.8
7.1
6.1
6.5
5.5
5.8
5.1
5.3
4.5
4.8
4.2
4.4
3.8
4.0
3.5
3.6
3.2
3.3
2.8
2.9
2.6
2.7
2.5
2.6
2.3
2.4
2.1
2.2
1.8
1.8
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
3.5
All products are sold to the commercial specifications shown for any additional reliability testing or extended parameters, please consult the factory.
As a reward for predicting the top three in the world, I received a short-sleeved T-shirt from EEW today.EEW logo
For a commemorative purpose, I asked a member of EEW to sign it. I will auction it whe...
1. Why is it easy for a double-seat valve to vibrate when working with a small opening? For a single core, when the medium is a flow-open type, the valve has good stability; when the medium is a flow-...
How to control 12864 to move a single line? Not move as a whole. . . . The move instruction is to move between 0x80-0x9f , and a line is from 0x80 to 0x87. . . Thank you all!!!...
Designing a good current-to-voltage (transconductance amplifier) converter using a voltage feedback amplifier (VFA) is a major challenge. In theory, a photodiode can produce a current or voltage outpu...
[Award Ceremony] The award ceremony for the August Classic Circuits event is here! ! ! https://bbs.eeworld.com.cn/thread-302981-1-1.html-------------------------------------------------- -------------...
Assume that data is read from 8-bit AD (if it is a higher-bit AD, the data type can be defined as int), the subroutine is get_ad();
1. Limited secondary filtering
/* A value can be adjust...[Details]
introduction
Since the beginning of the 21st century, the world of information has changed rapidly. Maybe a high-tech product will be released today and a better similar product will be releas...[Details]
1 Introduction
The high temperature tester is mainly used for temperature tracking measurement and data acquisition during the heating process. By systematically analyzing the test data, the...[Details]
Floating-point digital signal processing has become a constant requirement for precision technology, often in applications requiring high accuracy in areas such as aviation, industrial machinery, a...[Details]
The Portable Digital Data Acquisition System (PDDAS) uses LabVIEW Real-Time and PXI to control the wind tunnel test and record air pressure data from 128 different channels.
"The LabVIEW Real-...[Details]
All electronic design engineers and scientists have performed electrical signal analysis, or signal analysis for short. Through this basic measurement, they can gain insight into signal details and...[Details]
1 Introduction
With the acceleration of the pace of urban modernization, society has higher requirements for urban road lighting and urban lighting projects. The state has clearly required tha...[Details]
1 Introduction
Solar street lights are mainly composed of four parts: solar photovoltaic cell components, batteries, charge and discharge controllers, and lighting fixtures. The bo...[Details]
To differentiate their products in a crowded and competitive market, manufacturers of handheld devices often consider battery life and power management as key selling points for cell phones, PDAs, ...[Details]
My colleague and I spent the day chatting in the hotel bar. We had met with several customers. We were both wondering how come these engineers we were meeting knew almost nothing about analog techn...[Details]
July 11, 2012, Beijing - Altera Corporation (NASDAQ: ALTR) today announced the launch of 40-Gbps Ethernet (40GbE) and 100-Gbps Ethernet (100GbE) intellectual property (IP) core products. These core...[Details]
Editor's note: In order to help technicians or engineers who have knowledge of PIC microcontroller assembly language quickly master the method of using C language to program PIC microcontrollers, t...[Details]
1. Introduction