To order, simply select desired option from each category and place in the appropriate box. Available options are shown
and described on pages A-53 thru A-61. For additional options not shown in catalog, consult Customer Service Center. All
models have epoxy terminal seal and are compatible with all “bottom-wash” PCB cleaning methods.
Switch Function
8161
SPDT On-On
8168
SPDT On-Mom.
8261
DPDT On-On
Actuator or Plunger
S
.710"
high plunger
with .375" dia. cap
J80
Snap-in
J81
Snap-in with frame
J82
Snap-in with frame for LED
J86
Snap-in with frame & LED
L
.740" high plunger with
.395" dia. cap
L1
.740" high plunger with
.590" dia. cap
S1
.615" high plunger with
.200" dia. cap
S2
.710" high plunger with
.310" dia. cap
Bushing
H
.300" high, flat, hi torque
H9
.300" high, flat, hi torque
NONE
No bushing choice required
Y3
7.6mm, keyway
Terminations
A
Right angle, PC thru-hole
AV2
Vertical right angle,
PC thru-hole
C
PC Thru-hole
Z
Solder lug
A3
Right angle, snap-in, PC thru-hole
AV3
Vertical right angle, snap-in,
PC thru-hole
V3
.460" high, V-bracket
V4
.630" high, V-bracket
V6
.460" high, V-bracket
V21
.555" high, snap-in V-bracket
V31
.460" high, snap-in V-bracket
W
.750" long, wire wrap
Z3
Quick connect
Contact Material
B
Gold
P
Gold, matte-tin
Q
Silver
S
Silver, matte-tin
G
Gold over silver
R
Gold over silver,
matte-tin
Seal
E
Epoxy
I
Epoxy potted base
Cap Color
2
Black
1
White
3
Red
4
Orange
5
Yellow
9
Gray
Frame Color
2
Black
LED Color
3
Red
NONE
Models without LED
Dimensions are shown: Inches (mm)
Specifications and dimensions subject to change
A–52
www.ck-components.com
8060 Series
Alternate Action and Momentary Pushbutton Switches
SWITCH FUNCTION
SWITCH FUNCTION
POS. 1
POS. 2
CONNECTED TERMINALS
POS. 1
POS. 2
A
Pushbutton
NO.
POLES
MODEL NO.
C&K marking this side
C&K marking this side
SCHEMATIC
SP
8161
8168
ON
ON
ON
MOM.
2-3
2-3
2-1
2-1
SPDT
SPDT
Part number shown: 8161SHZQE
Terminal Nos.
For Reference Only
DP
8261
ON
ON
2-3,5-6
2-1,5-4
DPDT
DPDT
Part number shown: 8261SHZQE
MOM. = Momentary
All models
Terminal Nos.
For Reference Only
with all options when ordered with G, L, M or Q contact material.
CAP COLOR
ACTUATOR—SNAP-IN FRONT MOUNT
ACTUATOR OR PLUNGER
J80
SNAP-IN
PANEL MOUNTING
OPTION
CODE
*
CAP COLOR
BLACK
WHITE
RED
ORANGE
YELLOW
GRAY
*Increase this dimension to
.620/.625 (15,75/15,88)
for .091/.125 (2,41/2,18)
thick panels.
2
1
3
4
5
9
Cap Finish: matte.
Other colors available, consult
Customer Service Center.
Available with C, W, Z or
Z3 terminations.
NOTE:
Caps & frames available
separately, see pages A-60 and A-61.
J81
SNAP-IN WITH BLACK FRAME
PANEL MOUNTING
*
*Increase this dimension to
.620/.625 (15,75/15,88)
for .091/.125 (2,41/2,18)
thick panels.
Third Angle
Projection
Dimensions are shown: Inches (mm)
Specifications and dimensions subject to change
A–53
www.ck-components.com
8060 Series
Alternate Action and Momentary Pushbutton Switches
CAP COLOR
A
Pushbutton
J82
ACTUATOR—SNAP-IN FRONT MOUNT
ACTUATOR OR PLUNGER
SNAP-IN WITH BLACK FRAME FOR LED
Available with C, W, Z or Z3 terminations.
LED not included.
For LED information, see page A-61.
NOTE:
Caps & frames available
separately, see pages A-60 and A-61.
Other colors available, consult
Customer Service Center.
OPTION
CODE
CAP COLOR
BLACK
WHITE
RED
ORANGE
YELLOW
GRAY
2
1
3
4
5
9
CAP COLOR
LED COLOR
ACTUATOR—SNAP-IN FRONT MOUNT
J86
SNAP-IN WITH BLACK FRAME AND LED
ACTUATOR OR PLUNGER
PANEL MOUNTING
*
8161J86ZQE223
SPDT
Available with C, W, Z or Z3 terminations and SPDT models only.
* Increase this dimension to
.620/.625 (15,75/15,88)
for .091/.125 (2,31/3,18)
thick panels.
NOTE:
Caps & frames available
separately, see pages A-60 and A-61.
Other colors available, consult
Customer Service Center.
OPTION
CODE
CAP COLOR
BLACK
WHITE
RED
ORANGE
YELLOW
GRAY
OPTION
CODE
LED COLOR
RED
2
1
3
4
5
9
3
For LED information, see page A-59.
Third Angle
Projection
Dimensions are shown: Inches (mm)
Specifications and dimensions subject to change
A–54
www.ck-components.com
8060 Series
Alternate Action and Momentary Pushbutton Switches
CAP COLOR
PLUNGER
ACTUATOR OR PLUNGER
A
Pushbutton
PLUNGER WITH CAP P/N 8018
S
PLUNGER WITH CAP P/N 7527
S1
PLUNGER WITH CAP P/N 7089
S2
L
PLUNGER WITH CAP P/N 8941
L1
PLUNGER WITH CAP P/N 8940
OPTION
CODE
CAP COLOR
BLACK
WHITE
RED
ORANGE
YELLOW
GRAY
2
1
3
4
5
9
Cap Finish: gloss. Cap supplied not installed.
Other colors available, consult Customer
Service Center.
NOTE:
When selecting plunger and cap option, bushing selection must also be made, see below.
BUSHING
H
H9
.300" HIGH THREADED, FLAT
.300" HIGH UNTHREADED, FLAT
NONE
NO BUSHING CHOICE REQUIRED
(JXX ACTUATORS)
Y3
7.6mm THREADED, KEYWAY
1/4±40 UNS-2A
H bushing standard with C, W, Z or Z3 terminations.
H9 bushing standard with A, A3, AV2, AV3, or
V3-V31 terminations.
Withstands 12 in./lbs. of torque with no distortion.
Withstands 12 in./lbs. of torque with no distortion.
NOTE:
When selecting bushing option, plunger selection must also be made, see above. No bushing option choice required when any JXX actuator option is selected.
NOTE.
Two mounting nuts, locking ring and lockwasher supplied standard with threaded bushings.
Optional mounting nut and locking ring styles and finishes available, see section “Technical Data and
Additional Hardware”.
Third Angle
Projection
Dimensions are shown: Inches (mm)
Specifications and dimensions subject to change
A–55
www.ck-components.com
8060 Series
Alternate Action and Momentary Pushbutton Switches
A
Pushbutton
C
PC THRU-HOLE
PC MOUNTING
TERMINATIONS
Z
SOLDER LUG
SPDT and DPDT
SPDT and DPDT
Not available with P, S or R contact material.
Z3
QUICK CONNECT
W
WIRE WRAP
.750
(19,05)
SPDT and DPDT
Not available with P, S or R contact material.
Mating quick connector available;
order part number 530100000, page A-61.
SPDT and DPDT
A
HOLE
RIGHT ANGLE, PC THRU-
.130
(3,3)
.138
(3,51)
8161SH9ABE2
SPDT
SECTION A-A
A3
RIGHT ANGLE, SNAP-IN, PC THRU-HOLE
PC MOUNTING
Not available with I seal.
Terminal bend radii and lead-in manufacturing option.
1. I use a simulator to compile, so where is the generated program? 2. For example, I want to call an XML file, but it is not in CE. How can I transfer the file to CE? If I connect, I can't find the C...
I'm urgently looking for a program for MSP430f2132+CC1100. It doesn't have to be complicated, it just needs to be able to simply send and receive data... I'm urgently looking for it... Thank you!...
The High-Tech Fair is about to start, which is a big event in our industry. According to the news, there are about 200 companies coming here. Almost all the top companies in our industry are participa...
[table=98%] [tr][td]If I use two coils in a flyback converter, will there be a phase difference between the two coils? If there is a phase difference, when one coil sends energy, does the other coil a...
What is electromagnetic compatibility
Electromagnetic compatibility (EMC) refers to the ability of a device or system to operate in accordance with requirements in its electromagnetic environment and ...
Remote keyless entry (RKE) systems have become popular with users, with more than 80% of new cars in North America and more than 70% in Europe equipped with RKE systems. In addition to the obvious ...[Details]
Analog engineers have traditionally struggled with complexity when designing power supplies that required multiple outputs, dynamic load sharing, hot-swap, or extensive fault-handling capabilities....[Details]
Abstract: In order to generate a stable excitation signal, the design of a digital frequency synthesizer is implemented on FPGA using Verilog hardware language. The design includes accumulator, wav...[Details]
In public places such as schools, government agencies, factories and mines, as well as public corridors in residential areas, the phenomenon of long-burning lights is very common, which causes a h...[Details]
The reason for the light decay of white LEDs: the decline of phosphor performance
So far, the rapid decline of the luminous performance of white light LEDs, especially low-power white light LE...[Details]
In recent years, lighting has become an important area that countries around the world are targeting to promote energy conservation and environmental protection. According to statistics, about 20% ...[Details]
Since the No. 4 blast furnace of Handan Iron and Steel was put into operation in 1993, its external equipment has been seriously aged, and the original PLC control system TDC3000 of the hot blast furn...[Details]
General LED lighting has a current limiting resistor in the driving circuit, and the power consumed by the resistor has nothing to do with the LED light emission. In order to improve efficiency, a...[Details]
This controller uses PIC16C54 single-chip microcomputer as the controller, and it is very easy to use: just connect a telephone line to the loudspeaker through the controller, and you can rem...[Details]
Abstract: The output of high-range acceleration sensor is less than 10 mV under the excitation of small signal. The noise of traditional test system may cover such small voltage signal, so that hig...[Details]
Since the late 1990s, with the demand for higher system efficiency and lower power consumption, the technological update of telecommunications and data communication equipment has promoted the deve...[Details]
System Overview
The system consists of a signal preprocessing circuit, a single-chip computer AT89C2051, a systematic LED display module, a serial port data storage circuit and system software...[Details]
introduction
At present, measuring instruments are developing towards networking, and each individual embedded instrument will become a node on the Internet. This system realizes the network...[Details]
Introduction
As the country increases its efforts to control the atmospheric environment, motorcycle emission regulations will become stricter year by year, and motorcycles that do not meet the...[Details]
1 Introduction to LED
With the development of science and technology, people have higher and higher requirements on automobile light sources. LED (Light Emitting Diode) has gradually attracted...[Details]