EEWORLDEEWORLDEEWORLD

Part Number

Search

F.MD.06A06.07.FA

Description
Mains Power Connector, 6A, 250VAC, Male
CategoryThe connector    The connector   
File Size263KB,2 Pages
ManufacturerNissei Electric Co.,Ltd.
Download Datasheet Parametric View All

F.MD.06A06.07.FA Overview

Mains Power Connector, 6A, 250VAC, Male

F.MD.06A06.07.FA Parametric

Parameter NameAttribute value
MakerNissei Electric Co.,Ltd.
Reach Compliance Codeunknown
ECCN codeEAR99
Other featuresSTANDARD: IEC 60320, 94V-0
Connector typeMAINS POWER CONNECTOR
Contact point genderMALE
Coupling typeSNAP
DIN complianceNO
IEC complianceYES
MIL complianceNO
Power Connector Ratings6A, 250VAC
Manufacturer's serial numberF.MD-F
OptionsGENERAL PURPOSE
Total number of contacts1
IEC Inlet Filters
With fuse holders and mains switch
A range of compact IEC 60320 inlet power entry modules combining
1 or 2 fuse holders for US and IEC fuses. Plus a unipolar or bipolar
rocker switch.
Designed for use in business, consumer and medical equipment,
VDU’s, vending machines and many other general purpose
applications.
F.MA-F.MB-F.MC-F.MD
series
Current ratings from 1A to 6A
Integral single or twin fuse holder
Unipolar or bipolar rocker switch
Snap-in or screw mount versions
Medical versions available
Mechanical Specifications
Manufacture:
metal case with built-in power line connector
according to IEC 60320,
1 (F.MA-F.MC) or 2 (F.MB-FMD) fuse holders for
fuses 5 x 20mm (IEC) or 6.3 x 32mm (US),
unipolar (F.MA-F.MB) or bipolar (F.MC-F.MD)
rocker switch;
internal components sealed with self-extinguishing
resin.
Connections:
IEC 60320 - Standard plug (INPUT);
faston 6.3 x 0.5mm or 2.8 x 0.5mm for filter
output terminals;
faston 2.8 x 0.5mm for fuse terminals;
faston 4.8 x 0.8mm for rocker switch terminals;
ground terminal connected to case.
F.MA.
F.MC.
F.MD.
01.– –.– –
01A. 04.– –.– –
07.– –.– –
02.– –.– –
3
2 x 2.5 0.047
2 x 2500
6
2x1
0.047
08.– –.– –
03.– –.– –
06A. 06.– –.– –
09.– –.– –
A = Filter output terminals 2.8 x 0.5mm
C = Filter output terminals 6.3 x 0.8mm
F = Snap-in mounting
G = Screw mounting
07 = Fuse 5 x 20mm
14 = Fuse 6.3 x 32mm
A = 1 Fuse + unipolar rocker switch
B = 2 Fuses + unipolar rocker switch
C = 1 Fuse + bipolar rocker switch
D = 2 Fuses + bipolar rocker switch
2 x 2500
F.MB. 03A. 05.– –.– –
1
2 x 10
0.047
Filter Range
(example pt no. - F.MA.01A.01.07.FA)
Code
l
R
(A)
L
(mH)
Cx
(µF)
Cy
(pF)
2 x 2500
I
L
(mA)
2 x 0.23
2 x 0.002
2 x 0.002
2 x 0.23
2 x 0.002
2 x 0.002
2 x 0.23
2 x 0.002
2 x 0.002
1
1
1
R
(MΩ)
Electrical Specifications
Rated voltage (V
R
):
max 250V, 50/60Hz
Rated current (I
R
):
Voltage test (2
S
.):
referred to room temperature = 40°C
line to ground 3000Vdc or 1800Vac
line to line 1700Vdc
Climatic category:
HPF (25/085/21);
Temperature range: -25°C to +85°C
Rocker switches:
6(4)A / 250Vac (Rated current),
50000 on-off operations;
10(4)A / 250Vac (Rated current),
10000 on-off operations;
values in ( ) relate to the inductive current;
inrush current test according to UL 1054 (35A).
Leakage current (I
L
):
at 220V, 50Hz, max value
Approvals
27
Homemade simple LED strobe light
In the cookie-cutter DIY and MOD occasions, many players have painstakingly transformed the lighting effects to be static. If there are thousands of identical transformation MODs on Lanparty, how can ...
yuandayuan6999 DIY/Open Source Hardware
k9f2808-NandFlash debugging process and experience
Hardware platform: ARM7 44b0x Software debugging platform: ADS1.2 Purpose: Debug a NandFlash of model: Samsung's k9f2808 with a capacity of 16M * 8Bit In the text: NF means NandFlash...
zzzzer16 Embedded System
Power supply circuit diagram of SUPERSYNC PWB-1537 and SUPERSYNC EM-1428 color display
Power supply circuit diagram of SUPERSYNC PWB-1537 and SUPERSYNC EM-1428 color display...
破茧佼龙 Power technology
A question about Verilog
Please help me analyze a program. I use a 40M crystal oscillator, so one clock cycle is 25ns. clk is the input and ledout is the output. I want to change the level of ledout once every second. The pro...
cuitjxg MCU
Tips for your first interview
Initial/telephone interviews are usually quite general. Applicants are advised to prepare in the following aspects: 1. Before the interview, you should browse the company's website and related informa...
爱在深秋 Talking about work
Live Review: New Opportunities in UWB Market on June 23
Live broadcast time: June 23 (Thursday) 14:00-16:25Live broadcast topic: New opportunities in the UWB marketWatch replay: Click to watch Questions and Answers Summary:Question content Reply contentWha...
EEWORLD社区 RF/Wirelessly

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 500  390  1416  773  101  11  8  29  16  3 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号