803-004-02Z15-3HY

Description
Circular Connector, 3 Contact(s), Stainless Steel, Female, Crimp Terminal, Receptacle,
CategoryThe connector    The connector   
File Size263KB,4 Pages
ManufacturerGlenair
Websitehttp://www.glenair.com/
Download Datasheet Parametric View All

803-004-02Z15-3HY Overview

Circular Connector, 3 Contact(s), Stainless Steel, Female, Crimp Terminal, Receptacle,

803-004-02Z15-3HY Parametric

Parameter NameAttribute value
MakerGlenair
Reach Compliance Codecompliant
ECCN codeEAR99
Back shell typeSOLID
Body/casing typeRECEPTACLE
Connector typeCIRCULAR CONNECTOR
Contact to complete cooperationNOT SPECIFIED
Contact point genderFEMALE
Coupling typeBAYONET
DIN complianceNO
empty shellNO
Filter functionNO
IEC complianceNO
MIL complianceNO
Plug informationMULTIPLE MATING PARTS AVAILABLE
Mixed contactsNO
Installation typeCABLE AND PANEL
OptionsGENERAL PURPOSE
Shell materialSTAINLESS STEEL
Housing size5
Termination typeCRIMP
Total number of contacts3
Series 803 “Mighty Mouse”
¼ Turn Bayonet Coupling
Series 803 Bayonet Crimp Receptacles
A
B
F
D
E
6–7
Shell Size- Insert
Arrangement
5-3
6-1
6-4
6-7
7-1
7-10
8-13
9-4
9-19
10-26
12-2
12-37
14-55
15-85
3 #23 Contacts
1 #16 Contact
4 #23 Contacts
7 #23 Contacts
1 #12 Contact
10 #23 Contacts
13 #23 Contacts
4 #16 Contacts
19 #23 Contacts
26 #23 Contacts
2 #12 Contacts
37 #23 Contacts
55 #23 Contacts
85 #23 Contacts
Push-To-Mate, ¼ Turn to Lock.
These quick-mating connectors feature
bayonet pins on the receptacle. Simply
push the connectors together, then
rotate the plug coupling nut 90° to lock
the connectors together.
Three Shell Mounting Options:
Jam nut with o-ring for rear panel
mounting, elliptical flange for front
or rear panel mounting, or in-line
receptacles for free-hanging cables.
Two Shell Styles:
Choose the integral
band platform for direct attachment
of a cable shield. Install a heat-shrink
boot, or overmold directly onto the
band platform. An accessory thread is
available for attaching strain reliefs and
backshells.
HOW TO ORDER
Sample Part Number
80 3 - 003
Series
803-003
Receptacle with
Banding Platform
for Direct
Attachment of
Cable Shield and
Overmold
-0 7
Shell Style
NF
Shell Material /
Finish
C
Aluminum / Black
Anodize
S
Contact Type
P
Pin
N
Shell Key
Position
N
Normal
Alternate
Key
Positions:
-07
Jam Nut
S
Socket
Standard #23 contacts
accept #22 through
#28 AWG wire. Special
contacts for #26 to #30
AWG are available. Use
the following contact
codes to specify these
contacts:
M
Aluminum / Electroless
Nickel
NF
-02
Flange Mount
Aluminum / Cadmium
with Olive Drab
Chromate
X
Y
Z
ZN
803-004
Receptacle with
Rear Accessory
Thread
Aluminum / Zinc-
Nickel with Olive Drab
Chromate
G
Pin #2630
ZNU
-01
In-Line
Aluminum / Zinc-Nickel
with Black Chromate
#23 contacts are packaged
with connectors. #16 and #12
contacts must be ordered
separately.
H
Socket #2630
Z1
Stainless Steel /
Passivated
© 2007 Glenair, Inc.
CAGE Code 06324
Printed in U.S.A.
GLENAIR, INC. • 1211 AIR WAY • GLENDALE, CA 91201-2497 • 818-247-6000 • FAX 818-500-9912
www.glenair.com
F-5
Rev. 05-APR-2007
E-Mail: sales@glenair.com
Series 803
F
G
H
J
K
L
M
I have a beginner's question for you guys.
I want to ask you guys: I want to learn programming that deals with hardware. I have some basic knowledge of C/C++. I want to ask, can I control a light on a circuit board to turn off or on? Is such a...
freebigfish Embedded System
A family of high-performance devices designed specifically for customers
Discuss TI's current research and exploration in the fields of high-performance DSP, multi-core and next-generation processors that adapt to future development trends.[flash]http://player.youku.com/pl...
德仪DSP新天地 DSP and ARM Processors
Knowledge discussion of msp430
1. How should sfrb and sfrw be understood? Isn't the range of sfrw 0x100 to 0x1FF? Whyis there a 0 (blue color) in the middle of Sfrw ADC12CTL=0x01a2H when it is defined in the book? 2. Port Px has 8 ...
zxjk001 Microcontroller MCU
Please help me, experts~~~
Electronic transformer: Output 4.5v 500ml Electronic transformer input: 100-240V 50-60HZ...
lalaso Power technology
A question about limit switches
Hello teachers, this is what I did. I used an l298n dual H-bridge to control a reduction motor, and the motor drove a pipe switch with a movable range of 90 degrees. Then I used a limit switch with tw...
grove_armweak Motor Drive Control(Motor Control)
[Synopsys IP Resources] Why In-Memory Computing Will Disrupt AI SoC Development
The drive for higher performance per watt in artificial intelligence (AI) algorithms is driving the development of specific hardware design techniques, including in-memory computing for system-on-chip...
arui1999 Integrated technical exchanges

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1515  2131  352  181  953  31  43  8  4  20 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号