EEWORLDEEWORLDEEWORLD

Part Number

Search

A303313

Description
30 A, BARRIER STRIP TERMINAL BLOCK, 1 ROW, 1 DECK
CategoryThe connector    terminals   
File Size239KB,6 Pages
ManufacturerCooper Industries
Download Datasheet Parametric View All

A303313 Overview

30 A, BARRIER STRIP TERMINAL BLOCK, 1 ROW, 1 DECK

A303313 Parametric

Parameter NameAttribute value
MakerCooper Industries
Reach Compliance Codeunknown
ECCN codeEAR99
Other featuresSAFETY APPROVAL: UL 94V-0, THERMOPLASTIC
Fastening methodSCREW
Manufacturer's serial numberA3000
Installation typeBOARD
Number of layers1
Rows1
Number of channels13
Rated current30 A
Rated voltage600 V
safety certificateUL; CSA; CE; IEC
Terminal and terminal strip typesBARRIER STRIP TERMINAL BLOCK
Wire gauge12 AWG
MAGNUM
®
A31940707WR
Series A3000, LP3000 & CB3000
Single Row Terminal Blocks
Single & Double Row
Filtered Connectors
Euro-MAG Series
PCB – Spring Clamp
SPECIFICATIONS
Rating:
A3:
30A, 600V* #12-22 AWG
LP3: 30A, 150V #12-22 AWG
CB3: 30A, 600V #12-22 AWG
Wire Range:
#12-22 AWG CU
Center Spacing:
.437” or 7/16” (11.10 mm)
Screw Size:
#6-32 zinc plated philslot screws.
Torque Rating:
9 in-lb.
Base:
Standoffs standard for easy flux washing.
Distance Between Barriers:
.32” (8.1 mm)
Recommended PCB Hole Diameter:
.076” (1.93 mm)
Operating Temperature:
105°C (221°F) max., -40°C
(-40°F) min.
Molded Material:
Black, UL Rated 94V0 Thermoplastic
Breakdown Voltage:
3500V (A3 & LP3); 8200V (CB3)
Agency Information:
UL/CSA; IEC Compliance,
CE Certified
*30A Rating achieved with a #10 copper wire crimped to a ring terminal;
20 Rating without ring terminal.
LP301105
CB31420807
A3000 & LP3000 Series
.437
(11.10)
.15
(3.8)
dia.
.65
(16.5)
Base & Rail Mount
Connectors
Poles
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
MOUNTING
ENDS
ONLY
A
C
Mount Ctrs.
Length
1.31
1.75
2.18
2.62
3.06
3.50
3.93
4.37
4.81
5.25
5.68
6.12
6.56
7.00
7.43
7.87
8.31
8.75
9.18
9.62
10.06
10.50
10.93
11.37
11.81
1.73
2.17
2.61
3.05
3.48
3.92
4.36
4.80
5.23
5.67
6.11
6.55
6.98
7.42
7.86
8.30
8.73
9.17
9.60
10.05
10.48
10.92
11.36
11.80
12.23
BARRIER &
MOUNTING
ENDS
B
Pole Ctrs.
.43
.87
1.31
1.75
2.18
2.62
3.06
3.50
3.93
4.37
4.81
5.25
5.68
6.12
6.56
7.00
7.43
7.87
8.31
8.50
9.18
9.62
10.06
10.50
10.93
11.37
11.81
BARRIER
ENDS
ONLY
C
Length
.98
1.43
1.87
2.31
2.75
3.18
3.62
4.06
4.50
4.93
5.37
5.81
6.25
6.68
7.12
7.56
8.00
8.43
8.87
9.31
9.75
10.18
10.62
11.06
11.50
11.93
12.37
.40
(10.2)
C
Mount End
Barrier End
.565
(19.3)
.76
(14.35)
A
Mount Centers
B
Pole Centers
Mount End
Barrier End
.02
(.5)
CB3000 Series
.437
(11.10)
.19
(4.8)
dia.
.32
(8.1)
C
Mount End
Barrier End
Power Distribution Blocks
.70
(17.8)
.61
(15.5)
WIRE MANAGEMENT PRODUCTS
Dimensions in inches. To convert to millimeters, multiply by 25.4.
A
Mount Centers
B
Pole Centers
Mount End
Barrier End
.02
(.5)
12
Can the nRF 51822 Bluetooth module be paired with a Bluetooth Smart smart bracelet?
I want to pair the nRF 51822 Bluetooth module with the Bluetooth Smart of a smart bracelet. The nRF51822 Bluetooth module acts as the host, and the smart bracelet acts as the slave, sending the data d...
liuyuhangcom729 RF/Wirelessly
The painful experience of PCB is worth learning for engineers
PCB, or printed circuit board, is the carrier of electronic circuits. In modern electronic products, PCB is used almost everywhere. PCB design is the last link of circuit design and also the redesign ...
ohahaha PCB Design
The role of parallel resistance on the capacitor of the integration circuit
[color=#000000][backcolor=white]In the book (The Art of Electronics), I saw "If the residual drift of the integrator is still too large for a given application, it may be necessary to put a large resi...
灞波儿奔 Analogue and Mixed Signal
Classic book recommendation: Android Internet of Things Development from Entry to Practice PDF Source Code
[align=center][align=left][size=5][b]Android Internet of Things Development from Getting Started to Actual Combat[color=#ff0000]([url=https://www.eeworld.com.cn/a17312]Click to download[/url])[/color]...
高进 Download Centre
My own summary of the situation where ucos causes task scheduling, please add to it and give me some feedback
1. The most basic: when the system starts running OSStart(), it will trigger a scheduling. 2. When a new task is created, if the system is in running state at this time, it will trigger a scheduling. ...
h295472204 Real-time operating system RTOS
[FR4133] GPIO and external interrupt
I made a board on Double Eleven: [url=https://bbs.eeworld.com.cn/thread-477716-1-1.html]https://bbs.eeworld.com.cn/thread-477716-1-1.html[/url] If you have to use it, then let's learn about FR4133. St...
ljj3166 Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1364  1489  604  2456  1590  28  30  13  50  33 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号