Part Number

Search

D3V-6G5M-1C3

Description
Snap Acting/Limit Switch, SPDT, Momentary, 6A, 8VDC, 2.4mm, Quick Connect Terminal, Short Hinge Roller Lever Actuator, Panel Mount, ROHS COMPLIANT
CategoryMechanical and electronic products    switch   
File Size1MB,14 Pages
ManufacturerOMRON
Websitehttps://www.omron.com
Environmental Compliance
Download Datasheet Parametric View All

D3V-6G5M-1C3 Overview

Snap Acting/Limit Switch, SPDT, Momentary, 6A, 8VDC, 2.4mm, Quick Connect Terminal, Short Hinge Roller Lever Actuator, Panel Mount, ROHS COMPLIANT

D3V-6G5M-1C3 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerOMRON
package instructionROHS COMPLIANT
Reach Compliance Codeunknown
ECCN codeEAR99
Actuator stroke2.4 mm
Actuator typeSHORT HINGE ROLLER LEVER
body width10.3 mm
body height15.9 mm
Body length or diameter27.8 mm
Contact (AC) maximum rated R load6A@250VAC
Maximum contact current (AC)6 A
Maximum contact current (DC)6 A
Contact (DC) maximum rated R load6A@8VDC
Maximum contact voltage (AC)250 V
Maximum contact voltage (DC)8 V
Electrical life500000 Cycle(s)
Manufacturer's serial numberD3V
Installation featuresPANEL MOUNT
Maximum operating force0.59 N
Maximum operating temperature105 °C
Minimum operating temperature-25 °C
Maximum pre-travel1.6 mm
sealIP00
surface mountNO
Switch actionMOMENTARY
switch functionSPDT
Switch typeSNAP ACTING/LIMIT SWITCH
Termination typeQUICK CONNECT
Miniature Basic Switch
D3V
Reliable Basic Switch with External Lever
• Available by 0.1 A, 6 A, 11 A, 16 A and 21 A models, all with
self-cleaning contacts. 0.1 A utilizes gold alloy crossbar
contacts for high reliability at low loads.
• Available with internally or externally fitted levers, and 2 fix-
ing positions for external levers.
• Conforms to EN61058-1 UL1054.
• Right-angle plunger option available in some models.
• RoHS Compliant.
Ordering Information
Model Number Legend
D3V-@@@@-@@@-@-@
1 2 3 4
5 6 7
8
9
6. Terminals
A:
Solder/quick-connect terminal (#187)
C2: Quick-connect terminal (#187)
C:
Quick-connect terminal (#250)
(optional without surge creepage tab flush around
terminals.)
7. Maximum Operating Force
5:
1.96 N {200 gf}
4A: 1.23 N {125 gf}
4:
0.98 N {100 gf}
3:
0.49 N {50 gf}
2:
0.25 N {25 gf}
Note:
These values are for the plunger models.
8. Mounting Hole Size
None: 3.1 mm
K:
2.9 mm
9. Special Code
None: Standard
H:
High temperature (125° C)
E:
Special rating: 21 (8) A
T:
High temperature (200
°
C)
1. Ratings
21: 20 (4) A at 250 VAC
16: 16 (3) A at 250 VAC
11: 11 (3) A at 250 VAC
6:
6 (2) A at 250 VAC
01: 0.1 A at 125 VAC
2. Contact Gap
None: 1 mm (F gap)
G:
0.5 mm (G gap)
3. Actuator
None: Pin plunger
1:
Short hinge lever
2:
Hinge lever
3:
Long hinge lever
4:
Simulated roller lever
5:
Short hinge roller lever
6:
Hinge roller lever
4. Hinge Position
None: Internal/Far from plunger
M:
External/Far from plunger
K:
External/Near plunger
5. Contact Form
1:
SPDT
2:
SPST-NC
3:
SPST-NO
Miniature Basic Switch
D3V
1
Usage diagram of various Arduino basic components
Usage diagram of various Arduino basic components Share what you see...
btty038 Power technology
The device outputs a 0-2V DC current. How can I read it into the computer through the RS232 line?
The device outputs a 0-2V DC, such as a 1.5V battery. How can I read it into the computer through the RS232 line? Then write a program in JAVA to display the voltage value on the screen? And can it be...
hzfzh1234 Embedded System
[Transfer] C compiler version and predefined macros for system judgment
[i=s]This post was last edited by lcofjp on 2020-5-4 18:02[/i]When writing portable C++ code you need to write conditional code that depends on compiler used or the OS for which the code is written. H...
lcofjp Programming Basics
AD21 interactive fast manual layout skills PCB reposition selected components in sequence reposition selected c...
[i=s]This post was last edited by xunke on 2021-12-20 15:43[/i]Reposition selected components one by one. I found that this function is rarely mentioned in online tutorials. I think this function is v...
xunke PCB Design
Basic knowledge of electronic applications (I)
1. Resistors are represented by "R" plus numbers in the circuit, such as: R1 represents the resistor numbered 1. The main functions of resistors in circuits are current shunting, current limiting, vol...
xuenan1981 MCU
Learning MCU--what should we do?
Words for beginners (1) Learning MCU - What should we do? Why should we learn MCU? MCU is a common course in electrical engineering majors in colleges and universities. Some schools even list it as an...
qinkaiabc Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2010  1028  1817  200  1623  41  21  37  5  33 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号