EEWORLDEEWORLDEEWORLD

Part Number

Search

AM2B-0515SH60-NZ

Description
2 Watt | DC-DC Converter
File Size197KB,4 Pages
ManufacturerAimtec
Websitehttp://www.aimtec.ca/
Download Datasheet Compare View All

AM2B-0515SH60-NZ Overview

2 Watt | DC-DC Converter

Series AM2B-NZ
2 Watt | DC-DC Converter
FEATURES:
6000VDC Isolation
Low Profile DIP 16 Package
Industry Standard Pinout
MTBF>1,000,000 hours
Unregulated Single Output Models
Operating temperature: -40°C to +85°C
High Efficiency up to 85%
RoHS Compliant
Models
Single output
Model
AM2B-0505SH60-NZ
AM2B-0512SH60-NZ
AM2B-0515SH60-NZ
AM2B-1205SH60-NZ
AM2B-1212SH60-NZ
AM2B-1215SH60-NZ
AM2B-2405SH60-NZ
AM2B-2412SH60-NZ
AM2B-2415SH60-NZ
Input Voltage
(V)
4.5-5.5
4.5-5.5
4.5-5.5
10.8-13.2
10.8-13.2
10.8-13.2
21.6-26.4
21.6-26.4
21.6-26.4
Output Voltage
(V)
5
12
15
5
12
15
5
12
15
Output Current
max
(mA)
400
167
133
400
167
133
400
167
133
Isolation
(VDC)
6000
6000
6000
6000
6000
6000
6000
6000
6000
Efficiency
(%)
76
79
78
76
80
79
77
80
78
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Input Specifications
Parameters
Voltage range
Nominal
5
12
24
Typical
4.5-5.5
10.8-13.2
21.6-26.4
Maximum
Units
VDC
Isolation Specifications
Parameters
Tested I/O voltage
Capacitance
Resistance
Conditions
60 sec
500VDC
Typical
10
>1000
Rated
6000
Units
VDC
pF
MOhm
Output Specifications
Parameters
Voltage accuracy
Short circuit protection
Short Circuit restart
Line voltage regulation
Load voltage regulation
Temperature coefficient
Ripple & Noise*
Minimum load current**
Conditions
See Tolerance Graph
Typical
±5
Continuous
Auto Recovery
±1.2
12
±0.03
150
10
Maximum
Units
%
For a 1% change of Vin
From 10% load to 100% load
At 100% load
20MHz Bandwidth
%
%
%/
o
C
mV p-p
% of Max
*
Test ripple & noise by “Parallel Cable Method” as described in Application Note “Ripple and Noise Measurement of Brick &
POL DC-DC Converters” available at www.aimtec.com
**
If the operating output current is less than 10% of maximum it is recommended to install a load resister in parallel with the
load to ensure the actual load current meets the minimum load current requirement.
General Specifications
Parameters
Switching frequency
Operating temperature
www.aimtec.com
F 051e R12.B
Conditions
100% load, nominal input
Typical
50
-40 to + 85
Maximum
Units
KHz
o
C
Tel: +1 514 620 2722
1 of 4
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only

AM2B-0515SH60-NZ Related Products

AM2B-0515SH60-NZ AM2B-0505SH60-NZ AM2B-1205SH60-NZ AM2B-1212SH60-NZ AM2B-1215SH60-NZ AM2B-2412SH60-NZ AM2B-2415SH60-NZ AM2B-NZ AM2B-0512SH60-NZ AM2B-2405SH60-NZ
Description 2 Watt | DC-DC Converter 2 Watt | DC-DC Converter 2 Watt | DC-DC Converter 2 Watt | DC-DC Converter 2 Watt | DC-DC Converter Analog Circuit, 2 Watt | DC-DC Converter 2 Watt | DC-DC Converter 2 Watt | DC-DC Converter 2 Watt | DC-DC Converter
PCB design specifications of a company
It took me a long time to scan it into a PDF from the Internet and share it with you...
白手梦想家 stm32/stm8
Win CE compiled file cannot be found
I'd like to ask you how cold and hot booting of Win CE works. I have a development board, 2410, running CE5. I have compiled a file into the kernel (by modifying the bib file), but I can't see it when...
xieguangye Embedded System
PCB Design
Dear teachers, the picture below is the PCB design of the DA converter in the ADI evaluation manual. How many layers is this board? On which layers are the components placed? How should I draw the PCB...
萤火 PCB Design
Where is today's sign-in?
I came to check it out early in the morning, but found that the sign-in function was gone....
UUC Talking
A temperature rise of 40 degrees is within the permissible range - How is it defined?
I am working on a 5W-7W isolated LED driver; At room temperature, the electrical performance is good, but it is a little hot to the touch; Ask an engineer if the temperature is right; After all, at hi...
czf0408 LED Zone
ZTE EMC Design Lecture Knowledge
Electrostatic discharge immunity test (.2) Radio frequency electromagnetic field Electrical fast transient pulse group immunity test (.4) Lightning surge immunity test (.5) Radio frequency field condu...
czf0408 Power technology

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1264  2026  1273  581  842  26  41  12  17  42 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号