Part Number

Search

25.840.4053.0

Description
Modular Terminal Block, 12A, 2.5mm2, 1 Row(s), 1 Deck(s)
CategoryThe connector    terminals   
File Size49KB,1 Pages
ManufacturerWieland Electric GmbH
Websitehttps://www.wieland-electric.com/
Environmental Compliance
Download Datasheet Parametric View All

25.840.4053.0 Overview

Modular Terminal Block, 12A, 2.5mm2, 1 Row(s), 1 Deck(s)

25.840.4053.0 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
Reach Compliance Codecompli
ECCN codeEAR99
Fastening methodSPRING LOADED
Manufacturer's serial number8213BFK
Installation typeBOARD
Number of layers1
Rows1
Number of channels10
Rated current12 A
safety certificateUL; CSA
Terminal and terminal strip typesMODULAR TERMINAL BLOCK
Conductor cross section2.5 mm2
Base Number Matches1
wiecon
wiecon
PC board connectors, spring clamp connection
spacings 5.00/5.08 mm
PCB
Rated cross section*:
2.5 mm
2
Rated current:
12 A
Connection range:
0.14 – 2.5 mm
2
solid / fine standed
250 V/4 kV/3 – Overvoltage category III
400 V/4 kV/2 – Overvoltage category II
1000 V/4 kV/1 – Overvoltage category I
* When using ferrules for conductor cross
section of 2.5 mm, use only ferrule no.
05.596.6127.0.
11
11
Type 8113/8213 BFK
Rated voltages: VDE 0110
UL ratings
CSA ratings
Approvals
Std. pack
GFL
G
T
Poles
Type 8113/8213 BFK .../F
No. 22 – 12 AWG
No. 22 – 12 AWG
Part no.
No. 22 – 12 AWG
No. 22 – 12 AWG
Part no.
300 V
300 V
Part no.
12 A
12 A
300 V
300 V
Part no.
12 A
12 A
qw
qw
Spacing: 5.00 mm
100
100
50
50
50
50
50
50
50
50
50
50
50
50
50
22.54
27.54
32.54
37.54
42.54
47.54
52.54
57.54
62.54
67.54
72.54
77.54
82.54
87.54
92.54
10
15
20
25
30
35
40
45
50
55
60
65
70
75
80
5
10
15
20
25
30
35
40
45
50
55
60
65
70
75
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
unmarked
25.820.3253.0
25.820.3353.0
25.820.3453.0
25.820.3553.0
25.820.3653.0
25.820.3753.0
25.820.3853.0
25.820.3953.0
25.820.4053.0
25.820.4153.0
25.820.4253.0
25.820.4353.0
25.820.4453.0
25.820.4553.0
25.820.4653.0
17 to 24pole upon request
marked
25.820.0253.0
25.820.0353.0
25.820.0453.0
25.820.0553.0
25.820.0653.0
25.820.0753.0
25.820.0853.0
25.820.0953.0
25.820.1053.0
25.820.1153.0
25.820.1253.0
25.820.1353.0
25.820.1453.0
25.820.1553.0
25.820.1653.0
unmarked
25.821.3253.0
25.821.3353.0
25.821.3453.0
25.821.3553.0
25.821.3653.0
25.821.3753.0
25.821.3853.0
25.821.3953.0
25.821.4053.0
25.821.4153.0
25.821.4253.0
25.821.4353.0
25.821.4453.0
25.821.4553.0
25.821.4653.0
17 to 24pole upon request
marked
25.821.0253.0
25.821.0353.0
25.821.0453.0
25.821.0553.0
25.821.0653.0
25.821.0753.0
25.821.0853.0
25.821.0953.0
25.821.1053.0
25.821.1153.0
25.821.1253.0
25.821.1353.0
25.821.1453.0
25.821.1553.0
25.821.1653.0
Spacing: 5.08 mm
100
100
50
50
50
50
50
50
50
50
50
50
50
50
50
22.70
27.78
32.86
37.94
43.02
48.10
53.18
58.26
63.34
68.42
73.50
78.58
83.66
88.74
93.82
10.16
15.24
20.32
25.40
30.48
35.56
40.64
45.72
50.80
55.88
60.96
66.04
71.12
76.20
81.28
5.08
10.16
15.24
20.32
25.40
30.48
35.56
40.64
45.72
50.80
55.88
60.96
66.04
71.12
76.20
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
unmarked
25.840.3253.0
25.840.3353.0
25.840.3453.0
25.840.3553.0
25.840.3653.0
25.840.3753.0
25.840.3853.0
25.840.3953.0
25.840.4053.0
25.840.4153.0
25.840.4253.0
25.840.4353.0
25.840.4453.0
25.840.4553.0
25.840.4653.0
17 to 24pole upon request
marked
25.840.0253.0
25.840.0353.0
25.840.0453.0
25.840.0553.0
25.840.0653.0
25.840.0753.0
25.840.0853.0
25.840.0953.0
25.840.1053.0
25.840.1153.0
25.840.1253.0
25.840.1353.0
25.840.1453.0
25.840.1553.0
25.840.1653.0
unmarked
25.841.3253.0
25.841.3353.0
25.841.3453.0
25.841.3553.0
25.841.3653.0
25.841.3753.0
25.841.3853.0
25.841.3953.0
25.841.4053.0
25.841.4153.0
25.841.4253.0
25.841.4353.0
25.841.4453.0
25.841.4553.0
25.841.4653.0
17 to 24pole upon request
marked
25.841.0253.0
25.841.0353.0
25.841.0453.0
25.841.0553.0
25.841.0653.0
25.841.0753.0
25.841.0853.0
25.841.0953.0
25.841.1053.0
25.841.1153.0
25.841.1253.0
25.841.1353.0
25.841.1453.0
25.841.1553.0
25.841.1653.0
292
Creative progress post of portable heart rate meter based on RL78G14 - Progress-7, using Interval Timer to realize phase difference pulse output
My system needs to realize two PWM outputs with a phase difference of 90 degrees. Considering the comings and goings, I decided to use the 12-bit Interval Timer in the board IC to realize it. The Inte...
shower.xu Renesas Electronics MCUs
Is there anyone attending the Shenzhen ST training course on March 18th and 19th?
Specially for STM32,,Beijing area seems to be No. 25, 26,,...
shenlao stm32/stm8
Applying SOFA in AC/DC Power Supply
...
czf0408 Power technology
Ask for advice: What does the embedded mobile phone driver do?
http://campus.chinahr.com/2010/pages/mediatekbj/jobs.asp Check out this page. I am a mobile phone driver and system developer. What do I do? Confused......
shangyl Embedded System
have a look
Look, xiexie...
smps DSP and ARM Processors
High-Bandwidth, High-Amplitude Peak Detection Circuit
[i=s] This post was last edited by paulhyde on 2014-9-15 03:20 [/i] The transistor in the picture is used for timed discharge, and it is not necessary to solder in the circuit. I have another question...
515164595 Electronics Design Contest

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2520  86  337  2461  238  51  2  7  50  5 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号