BAW56-V-G
Vishay Semiconductors
Small Signal Switching Diode, Dual
Features
• Silicon Epitaxial Planar Diode
• Fast switching dual diode with common
anode
• AEC-Q101 qualified
• Compliant to RoHS Directive 2002/95/EC
and in accordance to WEEE 2002/96/EC
2
1
1
3
2
17033
3
Mechanical Data
Case:
SOT-23
Weight:
approx. 8.1 mg
Packaging Codes/Options:
18/10K per 13" reel (8 mm tape), 10K/box
08/3K per 7" reel (8 mm tape), 15K/box
Parts Table
Part
BAW56-V-G
Ordering Code
BAW56-V-G-18 or BAW56-V-G-08
Type Marking
JDG
Remarks
Tape and reel
Absolute Maximum Ratings
T
amb
= 25 °C, unless otherwise specified
Parameter
Repetitive peak reverse voltage
= Working peak reverse voltage
= DC Blocking voltage
Forward continuous current
t
p
= 1 µs
Non repetitive peak forward
current
Power dissipation
1)
Test Condition
Symbol
V
R
= V
RRM
I
F
I
FSM
I
FSM
I
FSM
P
tot
Value
70
250
2
1
0.5
350
1)
Unit
V
mA
A
A
A
mW
t
p
= 1 ms
t
p
= 1 s
Device on fiberglass substrate
Thermal Characteristics
T
amb
= 25 °C, unless otherwise specified
Parameter
Thermal resistance junction to
ambient air
Junction temperature
Storage temperature range
1)
Test condition
Symbol
R
thJA
T
j
T
stg
Value
430
150
- 65 to + 150
Unit
K/W
°C
°C
Device on fiberglass substrate
For technical questions within your region, please contact one of the following:
www.vishay.com
DiodesAmericas@vishay.com, DiodesAsia@vishay.com, DiodesEurope@vishay.com
Rev. 1.0, 04-May-11
1
This document is subject to change without notice.
THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT
www.vishay.com/doc?91000
Document Number 85872
BAW56-V-G
Vishay Semiconductors
Electrical Characteristics
T
amb
= 25 °C, unless otherwise specified
Parameter
Test Condition
I
F
= 1 mA
Forward voltage
I
F
= 10 mA
I
F
= 50 mA
I
F
= 150 mA
V
R
= 70 V
Reverse current
Diode capacitance
Reverse recovery time
V
R
= 70 V, T
j
= 150 °C
V
R
= 25 V, T
j
= 150 °C
V
F
= V
R
= 0, f = 1 MHz
I
F
= 10 mA to I
R
= 1 mA,
V
R
= 6 V, R
L
= 100
Symbol
V
F
V
F
V
F
V
F
I
R
I
R
I
R
C
D
t
rr
Min.
Typ.
Max.
715
855
1000
1250
2.5
100
30
2
6
Unit
mV
mV
mV
mV
µA
µA
µA
pF
ns
Typical Characteristics
T
amb
= 25 °C, unless otherwise specified
1000
I
F
- Forward Current (mA)
100
T
j
= 100 °C
10
25 °C
1
0.1
0.01
0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0
14356
22290
V
F
- Forward
Voltage
(V)
Figure 1. Forward Current vs. Forward Voltage
Figure 2. Peak forward current
I
FM
=
f
(t
p
)
For technical questions within your region, please contact one of the following: Document Number 85872
DiodesAmericas@vishay.com, DiodesAsia@vishay.com, DiodesEurope@vishay.com
2
Rev. 1.0, 04-May-11
This document is subject to change without notice.
THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT
www.vishay.com/doc?91000
www.vishay.com
Legal Disclaimer Notice
www.vishay.com
Vishay
Disclaimer
ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE
RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.
Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively,
“Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other
disclosure relating to any product.
Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or
the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all
liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special,
consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular
purpose, non-infringement and merchantability.
Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of typical
requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements
about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular
product with the properties described in the product specification is suitable for use in a particular application. Parameters
provided in datasheets and/or specifications may vary in different applications and performance may vary over time. All
operating parameters, including typical parameters, must be validated for each customer application by the customer’s
technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase,
including but not limited to the warranty expressed therein.
Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining
applications or for any other application in which the failure of the Vishay product could result in personal injury or death.
Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk and agree
to fully indemnify and hold Vishay and its distributors harmless from and against any and all claims, liabilities, expenses and
damages arising or resulting in connection with such use or sale, including attorneys fees, even if such claim alleges that Vishay
or its distributor was negligent regarding the design or manufacture of the part. Please contact authorized Vishay personnel to
obtain written terms and conditions regarding products designed for such applications.
No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by
any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners.
Material Category Policy
Vishay Intertechnology, Inc. hereby certifies that all its products that are identified as RoHS-Compliant fulfill the
definitions and restrictions defined under Directive 2011/65/EU of The European Parliament and of the Council
of June 8, 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment
(EEE) - recast, unless otherwise specified as non-compliant.
Please note that some Vishay documentation may still make reference to RoHS Directive 2002/95/EC. We confirm that
all the products identified as being compliant to Directive 2002/95/EC conform to Directive 2011/65/EU.
Revision: 12-Mar-12
1
Document Number: 91000