812-22-008-30-016-101

Description
Board Stacking Connector, 8 Contact(s), 1 Row(s), Male, Straight, Solder Terminal, ROHS COMPLIANT
CategoryThe connector    The connector   
File Size267KB,1 Pages
ManufacturerMill-Max
Websitehttps://www.mill-max.com
Environmental Compliance
Download Datasheet Parametric View All

812-22-008-30-016-101 Overview

Board Stacking Connector, 8 Contact(s), 1 Row(s), Male, Straight, Solder Terminal, ROHS COMPLIANT

812-22-008-30-016-101 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerMill-Max
package instructionROHS COMPLIANT
Reach Compliance Codecompliant
ECCN codeEAR99
Connector typeBOARD STACKING CONNECTOR
Contact to complete cooperationGOLD (20) OVER NICKEL (100)
Contact completed and terminatedGOLD (20) OVER NICKEL (100)
Contact point genderMALE
Contact materialCOPPER ALLOY
DIN complianceNO
Filter functionYES
IEC complianceNO
JESD-609 codee4
MIL complianceNO
Manufacturer's serial number812
Mixed contactsNO
Installation methodSTRAIGHT
Installation typeBOARD
Number of rows loaded1
OptionsGENERAL PURPOSE
Terminal pitch2.54 mm
Termination typeSOLDER
Total number of contacts8
UL Flammability Code94V-0
SPRING-LOADED CONNECTORS
Surface Mount with Alignment pins
Single and Double Row Strips
Modular contacts for use on .100” grid, available in
ten heights from .255” to .430”, supplied in single
and double row contact strips.
Precision-machined piston / base and gold plated
components assure a 1,000,000 min. cycle life.
Pistons have a .0275 mid stroke & .055 max
stroke.
Low resistance, high current contacts are rated at
2 amps continuous, 3 amps peak.
High temperature thermoplastic insulators are suit-
able for surface mount processes.
812 & 814 series contact strips are designed for
manual placement into Ø .023±.003” plated-thru-
holes in the circuit board prior to intrusive reflow
soldering.
Series 812...01X101
814...01X101
Single Row Series 812...01X101
Ordering Information
Single Row Series 812...01X101
812-22-0XX-30-01X101
Specify contact style
0-9
Specify # of contacts
03-64
Stroke
MM #0907-X Spring Loaded Connector
Double Row Series 814...01X101
814-22-0XX-30-01X101
Specify contact style
0-9
Specify # of contacts
06-72
CONTACT
STYLE
0
1
2
3
4
INITIAL HEIGHT
.042
DIA.
.059
DIA.
.055
.016
.072
DIA.
.017 DIA.
.198
.110
A
.069
A
.255
.275
.295
.315
.335
.100
(TYP)
MM #0908-X Alignment pins (2x)
Double Row Series 814...01X101
CONTACT
STYLE
5
6
7
8
9
INITIAL HEIGHT
A
.350
.370
.390
.410
.430
Technical Specifications
Materials:
Contact piston & Base: Machined copper alloy plated 20µ” gold
over 100µ” nickel
Spring: Beryllium copper plated 10µ” gold
Insulator: High temp. thermoplastic rated UL94 V-0
Mechanical:
Spring force @ initial height (A): 25 grams
Spring force @ mid stroke (B/2): 60 grams
Durability: 1,000,000 cycles min.
Electrical:
Voltage rating: 100Vrms/150Vdc
Current rating: 2A (continous), 3A (peak) per contact
Contact resistance: 20mΩ max.
Insulation resistance: 10,000MΩ min.
Dielectric strength: 700Vrms min.
RoHS
2002/95/EC
Capacitance: 1pF max.
MM #0907-X Spring Loaded Connector
.042
DIA.
.059
DIA.
.055
Stroke
.016
.072
DIA.
.017 DIA.
.198
.110
A
.069
.100
(TYP)
MM #0908-X Alignment pins (2x)
w w w. m i l l - m a x . c o m
8
516-922-6000
An electrical parameter measuring instrument based on 51 single chip microcomputer and using cs5463 chip
I am a novice among novices. I made a circuit diagram of a measuring instrument by myself. Can an expert help me see if this can be used?...
2896100272 51mcu
After the LCD backlight is turned off, I click the screen again and the screen lights up, but this click is invalid. What should I do?
After a period of time, the LCD backlight automatically turns off. After that, if the system has not entered sleep mode, the LCD backlight automatically turns on when the screen is clicked, but the cl...
lmx5078 Embedded System
Doubts for beginners
[i=s]This post was last edited by lylefuly on 2014-6-20 17:02[/i] [size=4] I want to learn zigbee recently, but I am still a student and don’t know much about it, so I want to ask for everyone’s opini...
lylefuly RF/Wirelessly
iPhone4 Power Bank
Hello everyone, does anyone have the circuit diagram of the iPhone 4 mobile power bank? Are there any requirements for making an iPhone mobile power bank? Is it the same as a normal mobile phone charg...
wzq06633278902 Power technology
Newbie Registration
I'm a newbie, please take care of me, thank you....
海绵宝宝22 Talking
How to use bootload in Keil C?
Suppose my main1() needs to be placed in the boot (starting from F800) area, and main2() needs to be placed in the area starting from 0000H. How should I write these two mains? [code] void main1() { ....
xu555xu Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1965  1185  2125  2328  2793  40  24  43  47  57 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号