Non resettable fuses
www.schurter.com/pg0_2
Miniature Fuse, 6.3 x 32 mm, Time-Lag T, UL, NNO, 250 VAC
72600
UL 248-14 · 250 VAC · Time-Lag T
Description
Standards
Approvals
- UL 248-14
- UL File Number: E42088
- High breaking capacity
Weblinks
pdf-datasheet, html-datasheet, General Product Information,
Approvals, CE declaration of conformity, RoHS, CHINA-RoHS, e-Shop,
SCHURTER-Stock-Check, Distributor-Stock-Check, Detailed request for
product
Technical Data
Rated Voltage
Rated Current
Breaking Capacity
Characteristic
Mounting
Admissible Ambient Air Temp.
Climatic Category
Material: Tube
Material: Endcaps
Unit Weight
Storage Conditions
Product Marking
125 - 250 VAC
2 - 20 A
35 A - 10 kA
Time-Lag T
Fuseholder / Clip
-40 °C to 70 °C
40/070/21 acc. to IEC 60068-1
Ceramic
Tin-Plated Nickel
2.5 g
0 °C to 60 °C, max. 70% r.h.
, Type, Current, Dielectric strength,
Characteristic, Approvals
32 mm
Dimensions
ø 6.35
±0.06
31.8
±0.8
Pre-Arcing Time
Rated Current In
2 A - 3 A
4 A - 20 A
. x In min.
60 min
60 min
.35 x In max.
60 min
60 min
2.0 x In min.
5 s
12 s
2.0 x In max.
120 s
120 s
Fuses
72600
www.schurter.com/pg0_2
Variants
Rated Cur-
rent [A]
Rated Vol-
tage [VAC]
Breaking
Capacity
Voltage Drop
.0 In typ.
[mV]
610
315
270
255
240
168
150
166
210
150
165
150
175
168
Power Dissi-
pation . I
n
typ. [mW]
310
650
530
850
860
1650
900
1750
1970
1520
2150
2500
3700
4500
Melting I²t
0.0 Intyp.
[A²s]
8.4
47
84
170
200
600
690
1130
1360
100
38
70
330
1300
l
l
l
l
l
l
l
l
l
l
l
l
l
l
Order Number
Non resettable fuses
0.4
1.6
2
2.5
3
4
5
6.3
7
8
10
12.5
16
20
250
250
250
250
250
250
250
250
125
125
125
250
250
250
1)
2)
1)
1)
1)
1)
1)
1)
1)
2)
2)
3)
3)
3)
7033.8130
7043.8110
7043.8120
7043.8130
7043.8140
7043.8150
7043.8160
7043.8170
7043.8180
7043.8190
7043.8200
7043.8210
7043.8220
7043.8230
1) 10 kA @ 125 VAC , p.f. = 0.7 - 0.8 / 200 A @ 250 VAC , p.f. = 0.7 - 0.8
2) 10 kA @ 125 VAC , p.f. = 0.7 - 0.8
3) 10 kA @ 125 VAC , p.f. = 0.7 - 0.8 / 1500 A @ 250 VAC , p.f. = 0.7 - 0.8
Packaging Unit
Small Box Pack (10 pcs.)
Time-Current-Curves
100000
≤
3A
>
_
4A
10000
1000
Time in Seconds
100
10
1
0.1
0.01
0.001
1
10
Multiple of Rated Current In
2
The specifications, descriptions and illustrations indicated in this document are based on
Fuses
current information. All content is subject to modifications and amendments.
06.04.2013