RTBH151206BADD6K12025G

Description
ROTARY CODED SWITCH-6POSITIONS, DP6T, LATCHED, PANEL MOUNT-THREADED, ROHS COMPLIANT
CategoryMechanical and electronic products    switch   
File Size357KB,6 Pages
ManufacturerC&K
Environmental Compliance
Download Datasheet Parametric View All

RTBH151206BADD6K12025G Overview

ROTARY CODED SWITCH-6POSITIONS, DP6T, LATCHED, PANEL MOUNT-THREADED, ROHS COMPLIANT

RTBH151206BADD6K12025G Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerC&K
package instructionROHS COMPLIANT
Reach Compliance Codecompliant
ECCN codeEAR99
body width17.78 mm
body height21.2 mm
Body length or diameter21 mm
Contact (AC) maximum rated R load.02A@10VAC
Maximum contact current (AC)0.02 A
Maximum contact voltage (AC)10 V
Electrical life25000 Cycle(s)
Graduation angle15 deg
JESD-609 codee4
Manufacturer's serial numberRTBH
Installation featuresPANEL MOUNT-THREADED
Number of positions6
Number of switching segments1
surface mountNO
Switch actionLATCHED
switch functionDP6T
Switch typeROTARY CODED SWITCH
Terminal surfaceGold (Au)
Termination typeSOLDER
C&K RTBH Series
1-2 Pole Coded Rotary Switches
Features/Benefits
Totally sealed
Detent angles, 15 , 22.5 , 30 and 36
Multi pole
Coding functions
Robust construction
Specifications
CONTACT RATING: S Contact material: Switch: 250mA, 5VA
resistive load. Carry: 5 AMPS
ELECTRICAL LIFE: Up to 25,000 operations.
OPERATING TORQUE: 5Ncm±30% (with 1 module).
MECHANICAL STOP RESISTANCE: > 70 Ncm.
BUSHING MOUNTING TORQUE: 100 Ncm.
CONTACT RESISTANCE: < 100 mΩ.
INSULATION RESISTANCE: > 109
DIELECTRIC STRENGTH: 500 V rms.
Typical Applications
Telecommunications
Military
Instrumentation
Heavy-duty industrial equipment
Materials
HOUSING: PBT thermoplastic and PC thermoplastic
STATIONARY CONTACTS & TERMINALS: Nickel alloy, gold or
silver plated, insert molded in PBT thermoplastic.
ROTOR: Printed circuit, gold or silver plated.
ACTUATOR: Steel
BUSHING: Brass
HARDWARE: Stop pin and spring: Stainless steel
All models are RoHS compliant and compatible.
NOTE:
For the latest information regarding RoHS compliance, please go to:
www.ittcannon.com/rohs.
NOTE:
Specifications and materials listed above are for switches with standard options.
For information on specific and custom switches, consult Customer Service Center.
Build-A-Switch
To order, simply select desired option from each category and place in the appropriate box. Available options are shown and
described on pages L-27 thru L-31. For additional options not shown in catalog, consult Customer Service Center.
L
Rotary
Designation
RTBH
Indexing
15
15°
22.5
22.5°
30
30°
36
36°
Number of Switch
Functions**
1
1 Function
2
2 Functions
Switch Function
Number of Poles (first digit)
Maximum Position (second & third digit)
or code (binary code = B, complement = C,
direct +complement = BC)
Stops
B
Binary code
B
Stop with number of positions
116
22.5 index, SP, 16 positions
S
Without
112
30 index, SP, 12 positions
Mounting Style
206
DP, 6 positions
AD
Standard bushing for panel mount
C
Complement
DE
Sealed bushing for panel mount
BC
Direct + complement
Shaft Diameter
D6
6 mm (.236)
D63
6.35 mm (.250)
Option of Shaft
(NONE)
M10X5
Shaft with flat
Actuator Option Angle*
(NONE)
K0
0° angle
Actuator Length
K60
60° angle
25
25 mm (.984)
K90
90° angle
Contact Material
K120
120° angle
S
Silver plated
K180
180° angle
G
Gold plated
K270
270° angle
Dimensions are shown: Inch (mm)
Specifications and dimensions subject to change
* Other angles available by request
** Several functions can be combined. For more information consult us.
L–26
www.ittcannon.com
OMAP-L138 platform issues
Just got started with TI's platform: (I chose OMAP-L132, but there are no films or thousands of pages of documentation yet, so I chose OMAP-L138 first) 1.Does TI provide test code and bare metal sampl...
zhiha258 DSP and ARM Processors
"Operational Amplifier Parameter Analysis and LTspice Application Simulation" Reading Notes 4 - Beautiful Diamond
Chapter 3 of the book "Operational Amplifier Parameter Analysis and LTspice Application Simulation" is about special amplifiers, including four types of special amplifiers: instrumentation amplifiers,...
gmchen Analog electronics
Advice for novice electricians
There are three essential books for getting started. The first is "Primary Textbook for Maintenance Electricians". Focus on the three chapters of low-voltage electrical appliances, asynchronous motors...
postlily Industrial Control Electronics
Research on Embedded Linux Application Development Based on ARM
0 Introduction In today's society, embedded systems have penetrated into all areas of people's work and life, and embedded processors have accounted for 94% of the market share of decentralized proces...
程序天使 Linux and Android
Why can't the HX711 electronic scale and 5kg pressure sensor supporting program be compiled?
(5): error C231: 'P3': redefinition D:\KEIL4\C51\INC\REG52.H(25): error C231: 'P4': redefinition D:\KEIL4\C51\INC\REG52.H(3): error C231: 'P6': redefinition D:\KEIL4\C51\INC\REG52.H(4): error C231: 'P...
15965343032 51mcu
msp430F5255 dual power rail problem
The MSP430F5255 datasheet (Figure 2 Vcc and Vio power sequence) states that AVCC and DVIO need to be powered on in a certain order. I would like to ask, in the design: 1. Is it necessary to design spe...
honghong Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1646  777  1790  1341  528  34  16  37  27  11 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号