B84112B0000L060

Description
Single Phase EMI Filter
CategoryAnalog mixed-signal IC    filter   
File Size195KB,11 Pages
ManufacturerTDK Corporation
Websitehttp://www.tdk.com
Download Datasheet Parametric View All

B84112B0000L060 Overview

Single Phase EMI Filter

B84112B0000L060 Parametric

Parameter NameAttribute value
MakerTDK Corporation
Reach Compliance Codeunknown
filter typeSINGLE PHASE EMI FILTER

B84112B0000L060 Preview

EMC Filters
Series/Type:
B84112B
The following products presented in this data sheet are being withdrawn.
Ordering Code
B84112B0000P030
B84112B0000L110
B84112B0000L060
Substitute Product
Date of
Withdrawal
2013-04-12
2013-04-12
2013-04-12
Deadline Last
Orders
2013-07-31
2013-07-31
2013-07-31
Last Shipments
2013-10-31
2013-10-31
2013-10-31
© EPCOS AG 2015. Reproduction, publication and dissemination of this publication, enclosures hereto and the
information contained therein without EPCOS' prior express consent is prohibited.
EPCOS AG is a TDK Group Company.
Ordering Code
B84112B0000L030
B84112B0000L020
B84112B0000L010
B84112B0000K060
B84112B0000K030
B84112B0000K010
Substitute Product
Date of
Withdrawal
2013-04-12
2013-04-12
2013-04-12
2013-04-12
2013-04-12
2013-04-12
Deadline Last
Orders
2013-07-31
2013-07-31
2013-07-31
2013-07-31
2013-07-31
2013-07-31
Last Shipments
2013-10-31
2013-10-31
2013-10-31
2013-10-31
2013-10-31
2013-10-31
For further information please contact your nearest EPCOS sales office, which will also support
you in selecting a suitable substitute. The addresses of our worldwide sales network are
presented at www.epcos.com/sales.
2-line filters
SIFI-B for enhanced insertion loss
Power line filters for 1-phase systems
Rated voltage 250 V DC/AC, 50/60 Hz
Rated current 1 to 20 A
Alternative version
Series B84112G (SIFI-G)
B84112B
offers a low-cost solution
Construction
2-line filters
Metal case
Polyurethane potting (UL 94 V-0)
Features
Compact design
Optimized leakage current
Cost-optimized construction
Also for assembly on top-hat rails
ENEC10, UL and CSA approval
Applications
Switch-mode power supplies in
– industrial electronics
– telecommunications
– data systems
– medical equipment
DC applications
Case styles and terminal styles
Case style A
Case style B
Case style K
Case style L
Case style P
Marking
Marking on component:
Manufacturer’s logo, ordering code,
rated voltage, rated current, rated temperature,
climatic category, date code
Minimum marking on packaging:
Manufacturer’s logo, ordering code
Please read
Cautions and warnings
and
Important notes
at the end of this document.
Tab connectors on face ends, lateral fixing lugs.
Particularly suitable for mounting on a shielding wall.
Tab connectors on face ends, fixing lugs on face ends.
IEC connector as per IEC 60320 C 14 on line side,
tab connectors on load side, mounting holes with metric thread.
Litz wires on face ends, fixing lugs on face ends
Pins fitting PCB standard grid
2
01/06
2-line filters
SIFI-B for enhanced insertion loss
Circuit diagram
LINE
L
LOAD
L’
B84112B
N
N’
SSB0525-W
Technical data and measuring conditions
Rated voltage V
R
Rated current I
R
Test voltage V
test
Leakage current l
leak
Climatic category (IEC 60068-1)
Approvals
250 V DC/AC, 50/60 Hz
Referred to 40
°C
ambient temperature
1414 V DC, 2 s (line/line)
2700 V DC, 2 s (lines/case)
At 230 V AC, 50 Hz
25/085/21 (–25
°C/+85 °C/21
days damp heat test)
EN 133200, UL 1283, CSA C22.2 No.8
Please read
Cautions and warnings
and
Important notes
at the end of this document.
3
01/06
2-line filters
SIFI-B for enhanced insertion loss
Characteristics and ordering codes
I
R
A
2
×
0.15
µF
(X2)
+
2
×
4700 pF (Y2)
2
×
0.15
µF
(X2)
+
2
×
4700 pF (Y2)
2
×
0.22
µF
(X2)
+
2
×
4700 pF (Y2)
C
R
L
R
mH
2
×
10
I
leak
mA
Case Approx. Ordering code
style weight
g
B84112B
Mounting plate
for top-hat rail
(ordering code)
V
R
= 250 V DC/AC, 50/60 Hz
1
<
0.5 A
B
K
L
<
0.5 A
B
L
<
0.5 A
B
K
L
P
<
0.5 A
B
K
L
<
0.5 A
B
L
<
0.5 A
B
110
110
140
110
110
110
110
140
140
210
140
140
150
150
210
150
200
200
200
700
700
B84112B0000A010
B84112B0000B010
B84112B0000K010
B84112B0000L010
C62122A0132B091
2
2
×
10
2
×
10
B84112B0000A020 —
B84112B0000B020 C62122A0132B091
B84112B0000L020 —
B84112B0000A030
B84112B0000B030
B84112B0000K030
B84112B0000L030
B84112B0000P030
B84112B0000A060
B84112B0000B060
B84112B0000K060
B84112B0000L060
C62122A0132B092
C62122A0132B092
3
6
2
×
0.33
µF
(X2)
+
2
×
4700 pF (Y2)
2
×
0.47
µF
(X2)
+
2
×
4700 pF (Y2)
2
×
0.68
µF
(X2)
+
2
×
4700 pF (Y2)
2
×
3.3
10
2
×
1.8
2
×
1.8
B84112B0000A110 —
B84112B0000B110 C62122A0132B092
B84112B0000L110 —
B84112B0000A120 —
B84112B0000B120 C62122A0132B092
20
Please read
Cautions and warnings
and
Important notes
at the end of this document.
4
01/06

Recommended Resources

PROTEL99SE package library for TI components
PROTEL99SE package library for TI components...
lorant PCB Design
BB Black Getting Started: TFTP and minicom installation
Yesterday we selected the host machine, so today we need to install TFTP and minicom. This way we can debug BeagleBone Blackle under the virtual machine. Let's install TFTP service first. With this, w...
lonerzf DSP and ARM Processors
I would like the detailed process of M4 construction, thank you.
I would like the detailed process of M4 construction, thank you....
915709857 NXP MCU
2011 Electrical Design Competition~~~ Final Preparations before the Competition
[i=s]This post was last edited by paulhyde on 2014-9-15 08:57[/i]The four-day and three-night competition is about to begin~~ How are you all preparing?~~ Share your thoughts~~...
yueye1235 Electronics Design Contest
LT8610 switching frequency switching Thanks
For transient operation, VIN may go as high as the absolute maximum rating of 42V regardless of the RT value, however the LT8610A/LT8610AB will reduce switching frequency as necessary to maintain cont...
尹子予刘学 ADI Reference Circuit
Compound op amp amplification problem
As shown in the figure above, the corresponding part of the explanation is in English. This part of the content comes from TI's SBOA015 op amp stability analysis. Now there is a demand to amplify a si...
呜呼哀哉 Analog electronics

Popular Articles

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1858  735  2468  2326  2593  38  15  50  47  53 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号