5 Energy Way, P.O. Box 1019, West Warwick, RI 02893 USA Tel. 800-424-9850 / 401-823-5200 Fax 401-823-8723 Email advintcorp@aol.com Internet http://www.advintcorp.com
.100" (2.54 mm) Pitch Board to Board Interconnections
NB/LNB - Single Row
Molded Female
DRS - Dual Row
Molded Female
NA - Single Row
Molded Male
DRA - Dual Row
Molded Male
KSS - Single Row
Peel-A-Way
®
Female
DKS - Dual Row
Peel-A-Way
®
Female
NEW PHOTO
Low Profile
Board to Board
KSA - Single Row
Peel-A-Way
®
Male
DKA - Dual Row
Peel-A-Way
®
Male
Features:
!
High reliability method of
interconnecting.
!
Reliable mechanical support.
!
Complete flexibility. If the board to
board spacing you need is not shown
on pages 54 - 55 , consult factory.
Terminals and Contacts:
Terminal: Brass - Copper Alloy 360,
ASTM-B-16
Contact: Beryllium Copper - Copper
Alloy 172, ASTM-B-194
Plating:
Terminal: Gold over Nickel or
Tin-Lead over Nickel
Contact: Gold over Nickel or
Tin-Lead over Nickel
Body Material:
Molded -
Glass filled thermoplastic
Polyester (P
.B.T.) U.L. Rated 94V-O,
-60
°
C to 140
°
C (-76
°
F to 284
°
F)
High Temp Molded
- High temp. glass
filled thermoplastic, U.L. Rated 94V-O,
-60
°
C to 260
°
C (-76
°
F to 500
°
F)
Peel-A-Way
®
- Polyimide Film - Temp.
range -269
°
C to 400
°
C(-452
°
F to 752
°
F)
Page 52
How To Order
Single and Dual RowFemale
NB
010
-01
T
G
Contact Plating
G - Gold
T - Tin-Lead
Terminal Plating
G - Gold
T - Tin-Lead
Terminal Type
See page 53 for available
terminal types.
Body Type
NB/LNB - Single Row Molded
HNB/HLNB - Single Row High Temp Molded
KSS - Single Row Peel-A-Way
®
DRS - Dual Row Molded
HDRS - Dual Row High Temp Molded
DKS - Dual Row Peel-A-Way
®
Number of Pins
NB/LNB - 3 - 32, KSS - 2 - 100
DRS - 20 - 70, DKS - 4 - 200
How To Order
Single and Dual Row Male
NA
Body Type
NA - Single Row Molded
HNA - Single Row High Temp Molded
KSA - Single Row Peel-A-Way
®
DRA - Dual Row Molded
HDRA - Dual Row High Temp Molded
DKA - Dual Row Peel-A-Way
®
010
-68
T
Terminal Plating
G - Gold
T - Tin-Lead
Terminal Type
See page 53 for available
terminal types.
Number of Pins
NA/HNA - 3 - 32, KSA - 2 - 100
DRA/HDRA - 20 - 70, DKA - 4 - 200
Peel-A-Way® covered by patent rights issued and or pending.
inch/(mm)
Quick turn delivery available on standard terminal types.
.
5 Energy Way, P.O. Box 1019, West Warwick, RI 02893 USA Tel. 800-424-9850 / 401-823-5200 •Fax 401-823-8723 •Email advintcorp@aol.com •Internet http://www.advintcorp.com
®
®
ADVANCED
Board to Board Interconnections
INTERCONNECTIONS
.100" (2.54 mm) Pitch Board to Board Interconnections
Male Terminal Information
Peel-A-Way® Only
.072 Dia.
(1.83)
.125
(3.18)
.070
(2.16)
.030
(.76)
.125
(3.18)
.125
(3.18)
.018 Dia.
(.46) Typ. 2
.018 Dia.
(.46) Typ. 2
Type -79
Peel-A-Way® Only
.072 Dia.
(1.83)
.125
(3.18)
Type -80
Peel-A-Way® Only
.072 Dia.
(1.83)
.125
(3.18)
.085
(2.16)
.125
(3.18)
Type -81
Type -444
.018 Dia.
(.46)
.125
(3.18)
.052
(1.32)
.103
(2.62)
.125
(3.18)
.018 Dia.
(.46)
.018 Dia.
(.46) Typ. 2
Type -68
.018 Dia.
(.46)
.125
(3.18)
.100
(2.54)
Type -43
.018 Dia.
(.46)
.125
(3.18)
Type -399
.018 Dia.
(.46)
.125
(3.18)
Type -185
.018 Dia.
(.46)
.125
(3.18)
.210
(5.33)
.335
(8.51)
.100
(2.54)
.100
(2.54)
.379
(9.63)
.100
(2.54)
.500
(12.70)
Board to Board
.125
(3.18)
.018 Dia.
(.46)
.018 Dia.
(.46)
.125
(3.18)
.018 Dia.
(.46)
.125
(3.18)
.018 Dia.
(.46)
.125
(3.18)
Type -42
.018 Dia.
(.46)
.125
(3.18)
Type -398
.018 Dia.
(.46)
.125
(3.18)
Type -403
.018 Dia.
(.46)
.125
(3.18)
Type -71
.018 Dia.
(.46)
.125
(3.18)
.585
(14.86)
.100
(2.54)
.100
(2.54)
.679
(17.25)
.100
(2.54)
.750
(19.06)
.100
(2.54)
.835
(21.21)
.018 Dia.
(.46)
.125
(3.18)
.018 Dia.
(.46)
.125
(3.18)
.018 Dia.
(.46)
.125
(3.18)
.018 Dia.
(.46)
.125
(3.18)
Female Terminal Information
Peel-A-Way® Only
.058 Dia.
(1.47)
Type -210
Peel-A-Way® Only
.058 Dia.
(1.47)
Type -85
Type -299*
.050(1.27) Molded Insulator Thickness
.072 Dia.
(1.83)
Type -49*
.072 Dia.
(1.83)
.015
(.38)
.083
(2.11)
.155
(3.94)
.031
(.79)
.095
(2.41)
.155
(3.94)
.082
(2.08)
.095
(2.41)
.028 Dia.
(.71)
.034 Dia.
(.86)
.038 Dia.
(.97)
.025 Dia.
(.64)
Type -04*
.072 Dia.
(1.83)
Type -51*
.072 Dia.
(1.83)
Type -01
Molded Body Only
.072 Dia.
(1.83)
Peel-A-Way® Only
.072 Dia.
(1.83)
Type -33
.120
(3.05)
.130
(3.30)
.165
(4.19)
.165
(4.19)
.110
(2.79)
.028 Dia.
(.71)
.020 Dia.
(.51)
.110
(2.79)
.125
(3.18)
.020 Dia.
(.51)
.125
(3.18)
.020 Dia.
(.51)
inch/(mm)
* These terminal types are available in either molded or Peel-A-Way®.
Peel-A-Way® covered by patent rights issued and or pending.
Recently, I need to make a driver to disable the functions of all external devices in the system, such as USB, serial port, CDROM, etc., and the driver itself is not allowed to be disabled or uninstal...
The following is a piece of code: int iMin, iMax; CProgressCtrl *p = (CProgressCtrl *)GetDlgItem(IDC_PROGRESS_TEST); p->SetRange(1000, 5000); p->GetRange(iMin, iMax); //It should return iMin=1000,iMax...
When reading the help for this function, I can't translate the following two sentences. Could someone please help me? 2. If an IOCTL caller passes in otherwise correct parameters with a buffer that is...
I have just started learning single-chip microcomputers, and now I am making a dynamic scanning display for digital tubes. The chip selection and segment selection share the P0 port, and p2.4 is used ...
Dual-mode inverters can operate both in conjunction with the grid and independently. These inverters can inject excess energy from renewable energy and storage devices into the grid, and withdraw p...[Details]
In recent years, with the increasing demand for manufacturing and automated production management, industrial barcode scanners have gradually become an indispensable part of the industrial manufact...[Details]
1. Equipment Overview
Shell-and-tube heat exchangers are a common heat exchange device used in chemical evaporation and heating equipment. Currently, the tubesheets of shell-and-tube heat exch...[Details]
Most of the houses we live in now are elevator buildings, mainly because it is more convenient to go up and down the stairs! It can also make life more comfortable. It even helps to increase the ad...[Details]
A parallel inverter consists of two thyristors (T1 and T2), a capacitor, a center-tapped transformer, and an inductor. The thyristors provide a current path, while the inductor L maintains a consta...[Details]
ISP devices, such as field programmable devices (FPGAs and CPLDs), do not require a programmer. Using programming kits provided by the device manufacturer, they employ a top-down modular design app...[Details]
In recent years, many people have switched to new energy vehicles, and this type of vehicle has indeed been highly sought after and is considered the future direction of automobile development, and...[Details]
The most significant feature of IPS panels is that both electrodes are located on the same surface, unlike other LCD panels, which have electrodes arranged on top and bottom surfaces in a three-dim...[Details]
Recently,
Xpeng Motors and Xinlian Integrated Circuit jointly announced the mass production of China's first hybrid silicon carbide product.
Designed and developed by Xpeng Motors and joint...[Details]
summary
There are multiple approaches to making industrial systems more intelligent, including applying artificial intelligence (AI) technology at the edge and in the cloud to sensor...[Details]
White light LEDs are voltage-sensitive devices. In actual operation, their upper limit is 20mA. However, the current often increases due to various reasons during use. If no protective measures are...[Details]
The Automotive Testing and Quality Assurance Expo (ATE 2025) will open on August 27th. At the expo, Rohde & Schwarz (R&S) will showcase six automotive testing solutions, themed "Intelligently Drivi...[Details]
Recently, South Korean robotics giant WIRobotics launched its first general-purpose humanoid robot, ALLEX, at the Robotics Innovation Center (RIH) at the Korea University of Science and Technology....[Details]
For autonomous vehicles to safely navigate the road, they must identify far more complex objects than just traffic lights, pedestrians, and other familiar objects. Among these obstacles is a crucia...[Details]
On August 22, according to the Ministry of Industry and Information Technology's official website, my country's first mandatory national standard for the control of hazardous substances in electric...[Details]