EEWORLDEEWORLDEEWORLD

Part Number

Search

MKS3PIN1-5AC220

Description
Power/Signal Relay, 3PDT, Momentary, 2700mW (Coil), 10A (Contact), 250VDC (Contact), AC Input, AC/DC Output, Socket Mount, ROHS COMPLIANT
CategoryMechanical and electronic products    relay   
File Size2MB,10 Pages
ManufacturerOMRON
Websitehttps://www.omron.com
Environmental Compliance
Download Datasheet Parametric View All

MKS3PIN1-5AC220 Overview

Power/Signal Relay, 3PDT, Momentary, 2700mW (Coil), 10A (Contact), 250VDC (Contact), AC Input, AC/DC Output, Socket Mount, ROHS COMPLIANT

MKS3PIN1-5AC220 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerOMRON
package instructionROHS COMPLIANT
Reach Compliance Codeunknown
ECCN codeEAR99
Other featuresCOIL OPERATE VOLTAGE(AC): 176 V, COIL RELEASE VOLTAGE(AC): 55 V
body width34.5 mm
body height52.5 mm
Body length or diameter34.5 mm
Coil current (AC) maximum value0.012 A
Coil power2700 mW
Coil resistance3550 Ω
Maximum coil voltage (AC)220 V
Coil/Input Power TypeAC
Contact (AC) maximum rated R load10A@250VAC
Maximum contact current (AC)10 A
Maximum contact current (DC)10 A
Contact (DC) maximum rated R load10A@250VDC
Maximum contact voltage (AC)250 V
Maximum contact voltage (DC)250 V
Contact/Output Power TypeAC/DC
Electrical life100000 Cycle(s)
Manufacturer's serial numberMK-S
Installation featuresSOCKET MOUNT
operating hours20 ms
Maximum operating temperature60 °C
Minimum operating temperature-40 °C
physical size34.5mm x 34.5mm x 52.5mm
GuidelineCE; IEC; TUV; UL
Relay actionMOMENTARY
Relay function3PDT
Relay typePOWER/SIGNAL RELAY
release time20 ms
surface mountNO
Termination typeSNAP-ON
General Purpose Relays
MKS
Exceptionally Reliable General Purpose
Relay now available with Lockable Test
Button
• IEC Rating of 7A 250 V AC 50/60 Hz,
General use 100,000 cycles.
• Mechanical indicator standard for all models.
• Optional features include lockable test button, LED
indicator, diode surge suppression, varistor, reverse
polarity, and alternate wiring styles.
• UL (RU/
C
RU), CE and TUV approved.
• RoHS Compliant.
Features
Two-way Action Test Button (Models with Lockable Test Button)
Relay in
Normal Operation
For Momentary
Operation
For Lock
Operation
Yellow
button
Slide the latching lever
to the first position,
then press the yellow
button with
an insulated
tool to operate the
contact.
Slide the latching lever
to the second position.
(The contact is now in
the locked position.)
Note:
The latching lever is Red for AC Coil versions and Blue for DC Coil versions.
Model Number Structure
Model Number Legend
MKS@@@@@-@-@
1 2 3 4 5
6
7
5. Coil Polarity
Blank: Standard
1:
Reverse polarity (DC coil only)
6. Surge Absorption
Blank:Standard
D:
Surge absorber diode (DC coil only)
V:
Surge absorber varistor (AC coil only)
7. Internal Connections DPDT
Blank: Standard
2 or 5: Non-standard connections.(Refer to “Terminal
Arrange-
ment/Internal Connection (Bottom View)”.)
8. Rated Voltage
(Refer to
“Coil Ratings”.)
1. Contact Form
2:
DPDT
3:
3PDT
2. Terminals
P:
Plug-in
3. Mechanical Indicator/Test Button
Blank:Mechanical indicator
I:
Mechanical indicator and lockable test button
4. LED Indicator
Blank: Standard
N:
LED indicator
General Purpose Relays
MKS
299
I use AD10 to draw schematics, but I don't know where the schematics for many components are.
As the title says, I searched Baidu for a long time and found some of them, but not others. I don't know where to find them. Is there any good method to guide me to find the schematic diagram quickly?...
似是而非君 PCB Design
FGPA-based web server
I want to use the DE2 115 board to make a web server. I only had a superficial exposure to FPGA boards before, but I am going to use this for my graduation project. I am very nervous!!! I have a few q...
nbnbnbyayaya FPGA/CPLD
mplayer cannot play videos after porting
: I ported mplayer yesterday, but it can't play videos. It plays MP3 very smoothly. The error message is as follows: /qt/MP/MPlayer-1.0pre8 # ./mplayer panda.mpg MPlayer 1.0pre8-4.1.2 (C) 2000-2006 MP...
bluejb119 Embedded System
www.kingofcoder.com Programming Articles Network
www.kingofcoder.com Programming Articles Network...
photosynthesis Embedded System
What a great introduction to CAN BUS! This is the kind of wise person who doesn't confuse others.
[i=s] This post was last edited by 5525 on 2016-5-29 20:28 [/i] [size=5] I will use the simplest words to make you understand. [/size][size=4] In the past [/size], after turning on the engine, you cou...
极度自卑 Automotive Electronics
[TI's first low-power design competition] Let EXP-MSP430FR5969 extend its working time by 10 times
Today I soldered a socket to the supercapacitor I bought last week so that it can be easily connected to LaunchPad. Because the supercapacitor is relatively large and I don't want to damage the struct...
dcexpert Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1915  2043  2228  1049  467  39  42  45  22  10 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号