EEWORLDEEWORLDEEWORLD

Part Number

Search

FFC-45T5AMEP2B

Description
Board Connector, 45 Contact(s), 1 Row(s), Male, Straight, Solder Terminal,
CategoryThe connector    The connector   
File Size54KB,1 Pages
ManufacturerHonda Tsushin Kogyo Co., Ltd.
Download Datasheet Parametric View All

FFC-45T5AMEP2B Overview

Board Connector, 45 Contact(s), 1 Row(s), Male, Straight, Solder Terminal,

FFC-45T5AMEP2B Parametric

Parameter NameAttribute value
MakerHonda Tsushin Kogyo Co., Ltd.
Reach Compliance Codeunknown
Connector typeBOARD CONNECTOR
Contact to complete cooperationTIN LEAD
Contact completed and terminatedTIN LEAD
Contact point genderMALE
DIN complianceNO
Filter functionNO
IEC complianceNO
JESD-609 codee0
MIL complianceNO
Plug informationMULTIPLE MATING PARTS AVAILABLE
Mixed contactsNO
Installation methodSTRAIGHT
Installation typeBOARD
Number of rows loaded1
OptionsGENERAL PURPOSE
Terminal pitch2.54 mm
Termination typeSOLDER
Total number of contacts45
2.54 mm pitch connector
Straight DIP type male connector for PCBs
FFC-( )(T )AMEP( )( )
Configuration of product Part No.
For PCBs
Straight DIP
FFC- ( ) (T ) AMEP ( ) ( )
Contact plating
1: Gold plate
2: Solder plate
Insulator color
Blank: Blue
B
: Black
Series name
No. of contacts: 1–52
Length of contact
Blank: Standard (6 mm)
T, T1–T18 (Refer to the following
dimension table.)
Type of contact
AMEP: 0.635 mm square contacts,
single row type
B
A
2.54
2.54
œ0.635
C
2.54
Dimensions
No. of
contacts
1
2
3
4
œ0.635
ø1
+0.1
0
5
6
7
8
9
10
2.54
– 0.05
+
A
2.54
5.08
7.62
10.16
12.70
15.24
17.78
20.32
22.86
25.40
27.94
30.48
33.02
35.56
38.10
40.64
43.18
45.72
48.26
50.80
53.34
55.88
58.42
60.96
63.50
B
2.54
5.08
7.62
10.16
12.70
15.24
17.78
20.32
22.86
25.40
27.94
30.48
33.02
35.56
38.10
40.64
43.18
45.72
48.26
50.80
53.34
55.88
58.42
60.96
63.50
66.04
No. of
contacts
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
A
66.04
68.58
71.12
73.66
76.20
78.74
81.28
83.82
86.36
88.90
91.44
93.98
96.52
B
68.58
71.12
73.66
76.20
78.74
81.28
83.82
86.36
88.90
91.44
93.98
96.52
99.06
D
11
A
+ 0.1
Components
Insulator
Contacts
Part No.
FFC- (1~52 ) AMEP( )( )
FFC- (1~52 )TAMEP( )( )
FFC- (1~52 )T1AMEP( )( )
FFC- (1~52 )T2AMEP( )( )
FFC- (1~52 )T3AMEP( )( )
FFC- (1~52 )T4AMEP( )( )
FFC- (1~52 )T5AMEP( )( )
FFC- (1~52 )T6AMEP( )( )
FFC- (1~52 )T7AMEP( )( )
FFC- (1~52 )T8AMEP( )( )
12
13
14
15
C
5
7
8.54
9.5
5.84
7.5
1.8
15.4
7.5
4
3.43
1.7 REF.
1.11 REF.
2
D
2.5
16
17
18
19
20
21
22
23
24
25
26
PCB layout for reference only
99.06 101.60
101.60 104.14
104.14 106.68
106.68 109.22
109.22 111.76
111.76 114.30
114.30 116.84
116.84 119.38
119.38 121.92
121.92 124.46
124.46 127.00
127.00 129.54
129.54 132.08
C
6
10.86
5.84
D
2.5
3.43
12.7
17.78
5.08
20.32
3
2.54
10.16
Part No.
FFC- (1~52 )T9AMEP( )( )
FFC- (1~52 )T10AMEP( )( )
FFC- (1~52 )T11AMEP( )( )
FFC- (1~52 )T12AMEP( )( )
FFC- (1~52 )T13AMEP( )( )
FFC- (1~52 )T14AMEP( )( )
FFC- (1~52 )T15AMEP( )( )
FFC- (1~52 )T16AMEP( )( )
FFC- (1~52 )T18AMEP( )( )
* T17 is obsolete.
5.72
6
5.72
Mating connectors:
DIC series or HKP series of female connectors
Z-220-( )FD( ) female connectors
DIP
SMT
Press-in
IDC
Wire
Soldering Crimping wrapping
Others
DAC904 Usage
Is there any expert who has used DAC904, please come out and give me some advice, how to use pin 15 and pin 28?...
guangge2010 Analog electronics
A few people are having problems and ask for help!
1. How to obtain and program the data between the electromagnetic flow meter and the PLC 2. The establishment of the A/D, D/A module and the pressure sensor and the inverter 3. The communication betwe...
eeleader Industrial Control Electronics
msp430 button control LED light
#include "io430.h"/*There are two ways to control the on and off of the LED light.Method 1: interrupt function. Method 2: use if(P4INBIT2) to judge.When writing code, try to follow the steps to avoid ...
fish001 Microcontroller MCU
I installed SQL Server CE on my Pocket PC, but after a power outage the installed files disappeared. How can I solve this problem?
I installed SQL Server CE on my PocketPC, but the files I installed disappeared after a power outage. How can I solve this problem? Can I set it to be permanently saved during installation? Or is ther...
adingx Embedded System
MATLAB simulation model for online parameter identification of permanent magnet synchronous motor based on MRAS
The MATLAB simulation model for online parameter identification of permanent magnet synchronous motor based on model reference adaptive MRAS can identify the motor resistance, inductance and permanent...
alphaalgorithm Motor Drive Control(Motor Control)
This is my first time using simulation. I encountered a problem. Please help me (solved)
[i=s] This post was last edited by 651076842 on 2013-12-28 11:55 [/i] Masters, what is the problem? My emulator is MSP-FET430UIF. The power light and mode light are both on. It is the first time I use...
651076842 Microcontroller MCU

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1295  100  732  2221  1323  27  3  15  45  25 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号