AC-DC Power Factor Correction Module, 1 Output, 150W, Hybrid, METAL, CASE K02, MODULE
CategoryPower/power management    The power supply circuit   
File Size994KB,28 Pages
ManufacturerBel
Websitehttp://www.belfuse.com
Download Datasheet Parametric View All

LK4501-9ERD2TB2 Overview

AC-DC Power Factor Correction Module, 1 Output, 150W, Hybrid, METAL, CASE K02, MODULE

LK4501-9ERD2TB2 Parametric

Parameter NameAttribute value
Brand NamePower-One
Is it lead-free?Contains lead
Is it Rohs certified?incompatible
MakerBel
Parts packaging codeMODULE
package instruction,
Manufacturer packaging codeCASE K02
Reach Compliance Codecompliant
ECCN codeEAR99
Analog Integrated Circuits - Other TypesAC-DC POWER FACTOR CORRECTION MODULE
Maximum input voltage255 V
Minimum input voltage85 V
JESD-30 codeR-MXMA-X
JESD-609 codee0
Number of functions1
Output times1
Maximum operating temperature71 °C
Minimum operating temperature-40 °C
Maximum output voltage15.09 V
Minimum output voltage14.91 V
Nominal output voltage15 V
Package body materialMETAL
Package shapeRECTANGULAR
Package formMICROELECTRONIC ASSEMBLY
Peak Reflow Temperature (Celsius)NOT SPECIFIED
Certification statusNot Qualified
surface mountNO
technologyHYBRID
Temperature levelOTHER
Terminal surfaceTIN LEAD
Terminal formUNSPECIFIED
Terminal locationUNSPECIFIED
Maximum time at peak reflow temperatureNOT SPECIFIED
Maximum total power output150 W
Fine-tuning/adjustable outputYES
Cassette Style
AC-DC Converters
S Series PFC
150 Watt AC-DC Converters with PFC
Input voltage range from 85...255 V AC
1or 2 isolated outputs up to 48 V DC
4 kV AC I/O electric strength test voltage
Universal input voltage range
Power factor
>0.95,
harmonics
<IEC/EN
61000-3-2
Input over- and undervoltage lock-out
Efficient input filter and built-in surge and transient
suppression circuitry
Fully isolated outputs
Outputs overload, open- and short-circuit proof
No derating over entire operating temperature range
Safety according to IEC/EN 60950
LGA
K-Series
111
4.4"
3U
80
3.2"
16 TE
168
6.6"
Summary
The K 4000/5000-series of AC-DC converters represents a
flexible range of power supplies for use in advanced elec-
tronic systems. Features include full power factor correc-
tion, high efficiency, high reliability, low output voltage noise
and excellent dynamic response to load/line changes.
The converter inputs are protected against surges and tran-
sients occurring at the source lines. An input over- and
undervoltage lock-out circuitry disables the outputs if the
input voltage is outside the specified ranges. Inrush current
limitation is included preventing circuit breakers and fuses
from being damaged at switch-on.
All outputs are overload, open- and short-circuit proof and
are protected against overvoltages by means of a built-in
suppressor diode. The outputs can be inhibited by a logic
signal applied to the connector pin 18 (i). If the inhibit func-
tion is not used pin 18 must be connected with pin 14 to en-
able the outputs.
LED indicators display the status of the converter and allow
visual monitoring of the system at any time.
Full input to output, input to case, output to case and output
to output isolation is provided. The modules are designed
and built according to the international safety standards
IEC/EN 60950 and have been approved by the safety
agencies LGA (Germany) and UL (USA). The UL Mark for
Canada has been officially recognized by regulatory au-
thorities in provinces across Canada.
The case design allows operation at nominal load up to
71°C in a free air ambient temperature. If forced cooling is
provided, the ambient temperature may exceed 71°C but
the case temperature must remain below 95°C under all
conditions.
A temperature sensor generates an inhibit signal which
disables the outputs if the case temperature
T
C
exceeds
the limit. The outputs are automatically re-enabled when
the temperature drops below the limit.
Various options are available to adapt the converters to in-
dividual applications.
The modules may either be plugged into 19 inch rack sys-
tems according to DIN 41494, or be chassis mounted.
Important:
These products are intended to replace the
LK 1000 and LK 2000 in order to comply with IEC/EN
61000-3-2.
Table of Contents
Page
Page
Electromagnetic Compatibility (EMC) ............................ 16
Immunity to Environmental Conditions ........................... 17
Mechanical Data ............................................................ 18
Safety and Installation Instructions ................................ 19
Description of Options .................................................... 22
Accessories .................................................................... 28
1/28
Summary .......................................................................... 1
Type Survey and Key Data .............................................. 2
Type Key .......................................................................... 2
Functional Description ...................................................... 3
Electrical Input Data ......................................................... 4
Electrical Output Data ...................................................... 6
Auxiliary Functions ......................................................... 12
Edition 5/5.2000
Moderator help STM32F17USB communication freeze
When using STM32F107 USB HID communication, if the USB cable is unplugged during communication, sometimes the STM32 will always be in USB interrupt and cannot jump out. Initially, the 3.1 USB library ...
lxxo stm32/stm8
"【TGF4042 Signal Generator】" Dual-channel signal measurement
Hello everyone! According to the plan, the output signal power should be measured this week, but unfortunately, I just found that the output signal power of this signal source cannot be set, only the ...
fine0406 Test/Measurement
My Ufun
I received my UFUN board. It is very beautiful, small and exquisite, with rich functions. It is worth playing with. I am now doing my homework and studying the resources in the class to prepare for th...
sxwsyc stm32/stm8
Basic DSP/BIOS API Call 3
9. Task Management TSK Task Management Module (1) void TSK_checkstacks (TSK_Handle oldtask, TSK_Handle newtask) (2) void TSK_checkstacks (TSK_Handle oldtask, TSK_Handle newtask) (3) void TSK_checkstac...
Jacktang DSP and ARM Processors
Microcalorimetric measurement system using thermocouple and 2182A nanovoltmeter
Microcalorimetry is used to determine energy relationships. Microcalorimetry techniques are often required when performing calorimetric experiments with small samples or slow heating rates. Microcalor...
程序天使 Test/Measurement
Qt Learning Road Chapter 47 View Selection
[p=22, null, left][color=#555555][font=Tahoma, Helvetica, SimSun, sans-serif][size=14px][color=#333333][backcolor=rgb(247, 247, 247)][font=Tahoma, Arial, Helvetica, sans-serif]Selection is a common op...
兰博 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1953  1809  448  2509  561  40  37  10  51  12 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号