EEWORLDEEWORLDEEWORLD

Part Number

Search

PB03W-60-1MM6SNT

Description
3A, 115/250VAC, MALE, MAINS POWER CONNECTOR, SOCKET
CategoryThe connector    The connector   
File Size272KB,3 Pages
ManufacturerPower Dynamics, Inc.
Websitehttp://www.powerdynamics.com/
Environmental Compliance
Download Datasheet Parametric View All

PB03W-60-1MM6SNT Overview

3A, 115/250VAC, MALE, MAINS POWER CONNECTOR, SOCKET

PB03W-60-1MM6SNT Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerPower Dynamics, Inc.
Reach Compliance Codecompliant
Other featuresSTANDARDS: IEC 60320; UL; CSA; VDE
Body/casing typeSOCKET
Connector typeMAINS POWER CONNECTOR
Contact to complete cooperationNOT SPECIFIED
Contact completed and terminatedNOT SPECIFIED
Contact point genderMALE
Contact materialNOT SPECIFIED
Coupling typeSNAP
DIN complianceNO
IEC complianceYES
MIL complianceNO
Power Connector Ratings3A, 115/250VAC
Manufacturer's serial numberPB
Installation typePANEL
OptionsGENERAL PURPOSE
Total number of contacts3
POWER LINE FILTER
PB Series
STRAIGHT, SNAP-IN/FLANGE MOUNT FILTER WITH IEC 60320
AC INLET SOCKET.
MECHANICAL DIMENSIONS
(Unit: mm)
50.1
30.3
22.5
40.0
28.5
4-R5
21.6
2-
3.3
40.0
3.5
SUGGESTED PANEL CUTOUT
(MOUNTING FROM FRONT)
45.9
47.4
41.8
54.0
FEATURES
The PB series, similar to PA and PASP series, offers filters with
IEC connector providing effective equipment protection of
line-to-ground noise up to 15 Amp, 250VAC. The compact
design filter with low leakage current is well suited for
applications that require strict national and international
emission standards. These filters are also available for
Medical application and offer extremely low Leakage current
to comply with UL544, UL2601 and CSA22.2 standards.
A ground choke can be added to enhance the grounding
ability of the circuit. Bleeder resistor can also be added to
prevent excessive voltages from developing across the filter
capacitors when there is no load.
G
28.3
20.6
31.0
24.0
21.9
4-R2
APPLICATIONS
Computer & networking equipment, Measuring & control
equipment, Data processing equipment, laboratory instruments,
Switching power supplies, other electronic equipment.
28.5
SUGGESTED PANEL CUTOUT
(MOUNTING FROM FRONT)
THICKNESS OF PANEL IS FROM
1.00mm to 1.6mm
TECHNICAL DATA
Rated Voltage: 115/250VAC
Rated Current: 1A, 2A, 3A, 6A, 10A, 15A
Power Line Frequency: 50/60Hz
Max. Leakage Current each
Line to Ground:
@ 115VAC 60Hz: 0.25mA
@ 250VAC 50Hz: 0.45mA
@ 115VAC 60Hz: 2
µ
A*
@ 250VAC 50Hz: 5
µ
A*
Hipot Rating (one minute)
Line to Ground: 2250VDC
Line to Line: 1450VDC
Temperature Range: -25C to +85C
* Medical application
3.6
51.8
40.9
28.3
20.6
Specifications subject to change without notice. Dimensions (mm). See Appendix A for
recommended power cord. See PDI full line catalog for detailed specifications on power cords.
145 Algonquin Parkway, Whippany, NJ 07981 • 973-560-0019 • FAX: 973-560-0076
e-mail: filtersales@powerdynamics.com •
www.powerdynamics.com
7
Common faults of temperature sensors and their solutions
[size=4][color=#000000][font=宋体] At present, temperature sensors are increasingly used in different fields, and problems of one kind or another are inevitable in the process of use. [/font] [font=宋体] ...
fish001 Analogue and Mixed Signal
Ask a silly question
Dear experts:Whydoes the phase of an AC signal lag after passing through a resistor? Is there any solution?...
pao9521 Analog electronics
Control your power devices with PMBus
[align=left][color=#000][color=rgb(205, 23, 31)][url=http://www.deyisupport.com/cfs-file.ashx/__key/communityserver-blogs-components-weblogfiles/00-00-00-01-07/3146.PM Bus_5F00_Blog_5F00_Color_5F00_2_...
maylove Analogue and Mixed Signal
What is the difference between an industrial router and a DTU?
Industrial routers, like DTUs, both realize wireless network data transmission functions, and the differences between the two are mainly in three aspects: appearance interface, usage method and applic...
baimatech77 Industrial Control Electronics
Are these three recommended directions useful for people with low education to make a comeback?
It is very convenient to learn IT technology now. In addition to studying in higher education schools, you can also go to training institutions on the market for systematic learning. The effect is the...
huaqingyuanjian Talking
How to disassemble the power amplifier unit in a tape recorder and make a power amplifier
How can I remove the power amplifier unit in a tape recorder and make a power amplifier using the existing speakers? What other components are needed? Can anyone give me a detailed answer? Thank you v...
DAMOMA Creative Market

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 666  2200  626  1396  1225  14  45  13  29  25 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号