EEWORLDEEWORLDEEWORLD

Part Number

Search

803-016-CC2ZNU14-235PN-72

Description
Interconnection Device
CategoryThe connector    The connector   
File Size525KB,4 Pages
ManufacturerGlenair
Websitehttp://www.glenair.com/
Download Datasheet Parametric View All

803-016-CC2ZNU14-235PN-72 Overview

Interconnection Device

803-016-CC2ZNU14-235PN-72 Parametric

Parameter NameAttribute value
Reach Compliance Codecompli
Connector typeINTERCONNECTION DEVICE
Base Number Matches1
803-009
Abrasion-Resistant Polyurethane Jacket
provides cold temperature flexibility and
high strength. Low smoke/zero halogen
material meets requirements for low
toxicity.
90% Tinned Copper Braid
is terminated
directly to connector with stainless steel
BAND-IT®
strap.
Watertight Overmold
provides strain
relief and protection.
Overmolded Cordset
Series 803 Harsh Environment Shielded Cordsets
These overmolded cordsets withstand abrasion and chemical exposure. Low smoke zero halogen jacket reduces the amount of
toxic and corrosive gasses emitted during combustion. Cable construction features silver coated stranded conductors with TFE
insulation, tinned copper braid shield and extruded polyurethane jacket. Choose single-ended pigtails or double-ended "back-
to-back" versions. Braid shield is attached directly to connector with
BAND-IT®
straps. Semi-rigid polyamide overmold provides
strain relief and environmental sealing.
Series 801 cordsets are now available with size #20HD, #16 and #12 contacts. Ordering information is found on the following
pages.
F
HARSH ENVIRONMENT CORDSET SPECIFICATIONS
Cable Jacket Material
Cable Shield
Conductors
BAND-IT®
Shield Termination Band
Current Rating
Test Voltage (Dielectric Withstanding Voltage)
Insulation Resistance
Operating Temperature
Solvent Resistance, Polyamide Overmold
Shielding Effectiveness
Cable jacket Flammability and Toxicity
Thermoplastic Polyurethane, Black, Low-Smoke, Zero-Halogen
Tin-Coated Copper Braid, 90% Minimum Coverage
Silver Coated Stranded Wire, TFE Insulated, Per M22759/11
Stainless Steel
#23 5 Amps, #20HD 7.5 Amps, #16 13 Amps, #12 23 Amps
#23 500 VAC, #20HD 700 VAC, #16 and #12 1800 VAC Sea Level
200 megohms minimum
-30° C. to +105° C.
Excellent Resistance to Most Solvents, Fuels, and Oils; Poor Resistance to
Strong Acids and Bipolar Solvents (Alcohol)
50 dB minimum from 100MHz to 1000MHz.
Toxicity Index 3.9 per NES 713
Oxygen Index 28% per ASTM D-2863
Smoke Index 24 per NES 711
© 2010 Glenair, Inc.
www.glenair.com
Dimensions in inches (millimeters) and are subject to change without notice.
CAGE Code 06324
Printed in U.S.A.
E-Mail: sales@glenair.com
GLENAIR, INC. • 1211 AIR WAY • GLENDALE, CA 91201-2497 • 818-247-6000 • FAX 818-500-9912
F-15
01-JANUARY-2010
Series 803
Series 803 Mighty Mouse ¼ Turn Bayonet Coupling
Overmolded ASAP Cordset Ordering Information
Zhongzhi Software System (Shanghai) Co., Ltd. Embedded Software Engineer Written Examination
Can anyone provide the written test questions for embedded software engineers? Can anyone who has taken the written test at Zhongzhi share their experience?...
maidi0018 Embedded System
LPC1500 Experience + SCT_4, lpcxpresso_RedState
[i=s] This post was last edited by freebsder on 2014-8-15 22:32 [/i]Select the project, then File->New->Other->Red State->Choose Target, and create a new state machine. The three boxes on the right of...
freebsder NXP MCU
The sad math of Atmega16A
In the Atmega16A microcontroller program (using cvavr programming), the given parameter i_Fade_time_temp = 7 is used to calculate the corresponding calculated value i_count. The calculation formula is...
ltwsq Microchip MCU
I would like to ask about the communication between two GPRS MODEMs.
Two GPRS modems are successfully dialed up in two PCs (under Linux operating system), and both get the PPP0 interface. The IPs obtained by the two PCs through PPP dialing are: 10.143.164.83 and 10.143...
yewuyi Embedded System
What is the difference between the Digital Cardiopulmonary Walk Test (DCW) and the Cardiopulmonary Exercise Test (CPX)?
Cardiac rehabilitation is the sum of various activities that patients need to carry out to ensure that they can achieve the best possible physical, mental and social conditions. The purpose of cardiac...
smartsens_2017 Medical Electronics
The synchronous rectifier buck circuit ended up boosting the voltage? I think something went wrong.
[i=s] This post was last edited by 零下12度半 on 2016-1-22 09:41[/i] We made this circuit. Logically, we input from the left, so it's a BUCK topology, but it's boosted. I can't figure it out. Please check...
零下12度半 Power technology

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 953  403  1493  1529  1963  20  9  31  40  36 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号