EEWORLDEEWORLDEEWORLD

Part Number

Search

LCS051T43ZB26CC

Description
SNAP ACTING/LIMIT SWITCH, SPDT, MOMENTARY, 16.7mm, PANEL MOUNT, ROHS COMPLIANT
CategoryMechanical and electronic products    switch   
File Size229KB,4 Pages
ManufacturerC&K
Environmental Compliance
Download Datasheet Parametric View All

LCS051T43ZB26CC Overview

SNAP ACTING/LIMIT SWITCH, SPDT, MOMENTARY, 16.7mm, PANEL MOUNT, ROHS COMPLIANT

LCS051T43ZB26CC Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerC&K
package instructionROHS COMPLIANT
Reach Compliance Codecompliant
ECCN codeEAR99
Actuator stroke16.7 mm
Actuator typeLEVER
body width6.4 mm
body height15.95 mm
Body length or diameter19.8 mm
Contact (AC) maximum rated R load6A@250VAC
Maximum contact current (AC)6 A
Maximum contact voltage (AC)250 V
Electrical life10000 Cycle(s)
Manufacturer's serial numberLCS
Installation featuresPANEL MOUNT
Maximum operating force1.47 N
Maximum operating temperature125 °C
Minimum operating temperature-40 °C
Maximum pre-travel13.8 mm
sealIP67
surface mountNO
Switch actionMOMENTARY
switch functionSPDT
Switch typeSNAP ACTING/LIMIT SWITCH
Termination typeWIRE
LCS Series
Subminiature Sealed Snap-acting Switches
Features/Benefits
Compact design
Long life and high electrical capacity
Quick connect, solder terminals,
PC terminals, wire leads
Wide variety of actuator styles
RoHS compatible, RoHS compliant
IP67
Specifications
CONTACT RATING: 6 AMP, 125/250 V AC
and
5 AMP, 125/250 V AC
0.1 AMP, 125/250 V AC
ELECTRICAL LIFE: 10,000 cycles
INSULATION RESISTANCE: 100 M ohm min.
DIELECTRIC STRENGTH: 1,000 VAC
OPERATING TEMPERATURE: –40ºC to +125ºC without wire
–40ºC to +85ºC with wires
OPERATING FORCE: (see ACTUATOR’S option sections).
MOUNTING: 2-56 screws, torque 2.3 in/lbs max.
NOTE:
Specifications and materials listed above are for switches with standard options.
For information on specific and custom switches, consult Customer Service center.
14
Typical Applications
Motorized equipment
Sump pump
Thermostatic controls
Computers
Air conditioners
14
Models Available
Materials
SWITCH HOUSING: Thermoplastic polyester or high temperature
thermoplastic (PTS) (UL 94V-0).
ACTUATOR BUTTON: Thermoplastic polyester.
SPRING: Copper alloy.
PIVOT: Copper alloy.
MOVABLE CONTACTS: Silver nickel
STATIONARY CONTACTS: Silver nickel on copper alloy.
TERMINALS: Copper alloy.
ACTUATOR LEVEL: Stainless steel.
J
Snap-acting
Build-A-Switch
To order, simply select desired option from each category and place in the appropriate box. Available options are shown and
described on pages J-27 thru J-29. For additional options not shown in catalog, consult Customer Service Center.
L
Series
LCS
Contact Rating
05
5 AMP, 125/250 V AC
6 AMP, 125/250 V AC
01
0.1 AMP, 125/250 V AC
C
S
14
Operating Force
1
150 grams
2
203 grams
Actuator
P00
Pin plunger
T00
0.45 mm short lever
T05
5.05 mm short lever
T07
7.05 mm short lever
T13
13.15 mm lever
T19
20.95 mm lever
T28
28.35 mm lever
T43
43.55 mm lever
S26
6.25 mm simulated lever
A05
4.85 mm lever roller
Circuitry
C
SPDT
W
SPST N.C.
Y
SPST N.O.
Wire Type AWG
20
20 AWG
22
22 AWG
24
24 AWG
26
26 AWG
28
28 AWG
30
30 AWG
Wire UL #
(when required)
A
UL1007
B
UL1015
C
UL1430
D
UL1061
E
UL1330
Terminations
S
Solder
Q
0.110 Quick Connect
P
PC Thru Hole
W
Wire leads potted
Z
Wire leads non-potted
Wire Side (when required)
A
Wire out the bottom
B
Wire out the right side
C
Wire out the left side
D
None
Dimensions are shown: mm
Specifications and dimensions subject to change
J–26
www.ck-components.com
Programming error
[i=s] This post was last edited by dontium on 2015-1-23 13:37 [/i] After I burned the program and ran it, it showed "Can\'t Set Breakpoint: Error 0x00000008/-1076 Error during: Break Point, Cannot set...
qiuliang012 Analogue and Mixed Signal
EE TALK——A look at the smart home/wearables around you
[align=left][font=微软雅黑][size=3]The trend of smart home has been blowing again and again, and the concept of wearables has also been popular in the past two years. As an ordinary person, have they real...
eric_wang Mobile and portable
Question + Do companies use TI or PIC more now?
[i=s] This post was last edited by Meng Lingmin on 2014-2-28 13:46 [/i] Nowadays, do more companies use TI or PIC? Personally, I prefer the low-power MSP430. I don't have much contact with PIC and don...
孟令民 Microcontroller MCU
A pitfall of threadx queue, and also pay attention to a mistake in the tough guy tutorial
I used threadx queue a few days ago and took a closer look. The function prototype is UINT tx_queue_create(TX_QUEUE *queue_ptr,CHAR *name_ptr,UINT message_size,VOID *queue_start,ULONG queue_size);mess...
freebsder Embedded System
Tianma full series LCD screen datasheets are released - you need to pay to download them on Panel
See attachment for details...
xiaochuan610 Integrated technical exchanges

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1965  2400  2025  1051  890  40  49  41  22  18 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号