55.12.8.240.20540

Description
Electromechanical Relay, DPDT-CO, MBB, AC/DC Output
CategoryMechanical and electronic products    relay   
File Size3MB,14 Pages
ManufacturerFINDER
Download Datasheet Parametric View All

55.12.8.240.20540 Overview

Electromechanical Relay, DPDT-CO, MBB, AC/DC Output

55.12.8.240.20540 Parametric

Parameter NameAttribute value
MakerFINDER
Reach Compliance Codecompliant
body width20.7 mm
body height35.8 mm
Body length or diameter27.7 mm
Coil operating voltage (AC)192 V
Coil resistance19100 Ω
Maximum coil voltage (AC)264 V
Nominal coil voltage240 V
Coil/Input Power TypeAC
Contact (AC) maximum rated power R load2500VA@400VAC
Contact (AC) maximum rated R load20A@400VAC
Maximum contact current (AC)20 A
Maximum contact voltage (AC)400 V
Contact/Output Power TypeAC/DC
Dielectric strength between coil and contacts2000 Vrms
Dielectric strength between breaking contacts1000 Vrms
Electrical life200000 Cycle(s)
End contact materialSILVER CADMIUM OXIDE
Number of terminals8
operating hours10 ms
Maximum operating temperature85 °C
Minimum operating temperature-40 °C
PCB hole count8
physical size27.7mm x 20.7mm x 35.8mm
Relay actionMBB
Relay style2 FORM C
Relay functionDPDT-CO
release time5 ms
Terminal length0.0048 inch
Termination typeSOLDER
55
55 Series - General purpose relays 7 - 10 A
Features
Printed circuit mount, general purpose
2, 3 & 4 Pole relays
55.12 - 2 Pole 10 A
55.13 - 3 Pole 10 A
55.14 - 4 Pole 7 A
AC coils & DC coils
Cadmium Free contacts (preferred version)
Contact material options
RT III (wash tight) option available
SERIES
55.12
55.13
55.14
Plug-in / PCB Relays
2 pole, 10 A
PCB mount
3 pole, 10 A
PCB mount
4 pole, 7 A
PCB mount
55.12
55.13
55.14
F
OR
UL
RATINGS SEE
:
“General technical information” page
V
Contact specification
Contact configuration
Rated current/Maximum peak current
Rated load AC1
Rated load AC15 (230 V AC)
Single phase motor rating (230 V AC)
Breaking capacity DC1: 30/110/220V
Minimum switching load
Standard contact material
Coil specification
Nominal voltage (U
N
)
Rated power AC/DC
Operating range
Holding voltage
Must drop-out voltage
Technical data
Mechanical life AC/DC
Electrical life at rated load AC1
Operate/release time
X-2013, www.findernet.com
Copper side view
Copper side view
Copper side view
2 CO (DPDT)
A
VA
VA
kW
A
10/20
250/400
2,500
500
0.37
10/0.25/0.12
300 (5/5)
AgNi
V AC (50/60 Hz)
V DC
VA (50 Hz)/W
AC
DC
AC/DC
AC/DC
cycles
cycles
ms
1.5/1
(0.8…1.1)U
N
(0.8…1.1)U
N
0.8 U
N
/0.5 U
N
0.2 U
N
/0.1 U
N
20 · 10
6
/50 · 10
6
200 · 10
3
10/5
4
1,000
–40…+85
RT I
3 CO (3PDT)
10/20
250/400
2,500
500
0.37
10/0.25/0.12
300 (5/5)
AgNi
6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240
6 - 12 - 24 - 48 - 60 - 110 -125 - 220
1.5/1
(0.8…1.1)U
N
(0.8…1.1)U
N
0.8 U
N
/0.5 U
N
0.2 U
N
/0.1 U
N
20 · 10
6
/50 · 10
6
200 · 10
3
10/5
4
1,000
–40…+85
RT I
4 CO (4PDT)
7/15
250/250
1,750
350
0.125
7/0.25/0.12
300 (5/5)
AgNi
Rated voltage/Maximum switching voltage V AC
mW (V/mA)
1.5/1
(0.8…1.1)U
N
(0.8…1.1)U
N
0.8 U
N
/0.5 U
N
0.2 U
N
/0.1 U
N
20 · 10
6
/50 · 10
6
150 · 10
3
11/3
4
1,000
–40…+85
RT I
Insulation between coil and contacts (1.2/50 µs) kV
Dielectric strength between open contacts V AC
Ambient temperature range
Environmental protection
Approvals
(according to type)
°C
1
Schematic diagram of EasyARM2131 development board
Schematic diagram of EasyARM2131 development board...
呱呱 MCU
Inductor and transformer testing methods and experience
3. Inductor and transformer detection methods and experience 1. Detection of color-coded inductors Set the multimeter to R×1, and connect the red and black test leads to any lead-out terminal of the c...
fighting Analog electronics
Can the official APP directly display humidity and power level?
[i=s]This post was last edited by Liang Zhijian on 2017-4-9 17:48[/i] I directly soldered the core board to the small board and powered it on. On the official APP with version number 3.3, I saw temper...
梁志坚 MEMS sensors
After debugging, CCS directly runs 8 cores.
I have been debugging C6678 these two days. It was working fine before. But now, after debugging the same project, all 8 cores are running directly without any other operations. The same happens when ...
taoranae86 DSP and ARM Processors
Help!!! Course Design - Detection of DC Motor Working Current
The teacher gave me this question and told me to use Protel to solve it. I have no idea how to do it. Can any expert give me some advice?...
ljx19851226 Test/Measurement
Driver novice help!
I recently disassembled a driver, but I know very little about it. Please help! There are two key functions at the beginning of the driver, which I don't quite understand. I guess my problem is relati...
860122 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2296  835  339  1768  2413  47  17  7  36  49 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号