EEWORLDEEWORLDEEWORLD

Part Number

Search

306E-114-3101

Description
Board Connector, 14 Contact(s), 1 Row(s), Male, Straight, 0.156 inch Pitch, Solder Terminal, Natural Insulator, Receptacle
CategoryThe connector    The connector   
File Size153KB,1 Pages
ManufacturerMethode Electronics Inc.
Download Datasheet Parametric View All

306E-114-3101 Overview

Board Connector, 14 Contact(s), 1 Row(s), Male, Straight, 0.156 inch Pitch, Solder Terminal, Natural Insulator, Receptacle

306E-114-3101 Parametric

Parameter NameAttribute value
MakerMethode Electronics Inc.
Reach Compliance Codeunknown
ECCN codeEAR99
Other featuresWITH HOOKS
Board mount optionsPCB EDGE LOCKING HOOK
subject depth0.45 inch
body length2.178 inch
Body/casing typeRECEPTACLE
Connector typeBOARD CONNECTOR
Contact to complete cooperationSN-PB ON NI
Contact completed and terminatedTIN/LEAD OVER NICKEL
Contact point genderFEMALE
Contact materialBRASS
contact modeRECTANGULAR
Contact resistance5 mΩ
Contact styleSQ PIN-SKT
DIN complianceNO
Dielectric withstand voltage1500VAC V
Filter functionNO
IEC complianceNO
maximum insertion forceLIF N
Insulation resistance500000000000 Ω
Insulator colorNATURAL
insulator materialNYLON
MIL complianceNO
Plug contact pitch0.156 inch
Plug informationMULTIPLE MATING PARTS AVAILABLE
Mixed contactsNO
Installation methodSTRAIGHT
Installation typeBOARD
Number of connectorsONE
PCB row number1
Number of rows loaded1
Maximum operating temperature105 °C
Minimum operating temperature-40 °C
OptionsGENERAL PURPOSE
PCB contact patternRECTANGULAR
polarization keyPOLARIZED HOUSING
Rated current (signal)7 A
GuidelineUL, CSA
reliabilityCOMMERCIAL
Terminal length0.125 inch
Terminal pitch3.96 mm
Termination typeSOLDER
Total number of contacts14
UL Flammability Code94V-0
Evacuation force-minimum valueLIF N
.156” (3.96mm)
Through Hole Vertical Mount Connector
3000 SERIES “TERMACON”
PART NUMBER LEGEND
30XX-XXX-XXXX
CONTACT TAIL DIMS (SEE TABLE 2)
CONTACT MATERIAL (SEE NOTE 1)
OPTIONS
2 - HIGH INSERTION FORCE CONTACT
3 - LOW INSERTION FORCE CONTACT
NO. OF POSITONS (SEE TABLE 1)
OPTIONS
0-
1-
3-
6-
7-
8-
WITH LEGS
WITH HOOKS
WITH HOOKS AND LOCKING RAMP
WITH LOCKING RAMP
WITH HOOKS, LOCKING RAMP AND POLARIZING KEY
WITHOUT HOOKS, W/ LOCKING RAMP AND POLARIZING KEY
CONTACT FINISH (SEE NOTE 2)
INSULATOR MATERIAL (SEE NOTE 1)
MATING HEADERS: 3100 SERIES
HOLE
LEG
LOCKING
RAMP
POLARIZING KEY &
LOCKING RAMP
Connector Products
1700 Hicks Road • Rolling Meadows, IL 60008 USA
Telephone: 847.392.3500 • Fax: 847.392.9404
email: mcpsales@methode.com • Web Page: www.methode.com
Some issues about converting simulink into C code using rtw toolbox
I am a DSP beginner and want to convert the block diagram of Simulink into C code and run it on DSP. My settings in RTW toolbox are: Solver: stop time select inf type select fixed-step hardware implem...
ziranyouxin Embedded System
How to use a microcontroller to control MOS tubes?
I have just started to learn MCU. Recently, I want to use MCU to control the opening and closing of MOS tube. Just opening and closing is enough. I want to use MCU to directly control the gate level. ...
joezz624 51mcu
About the issue of su: must be suid to work properly in tiny210 development board
When a general user of the embedded file system executes su root to switch to the root user, an error message appears: su: must be suid to work properlySolution: Modify busybox permissions, chmod 4755...
linrui0726 ARM Technology
In SPI bus communication, if a device is a master device, it can only be a master device forever, and if a device is a slave device, it can only be a slave device forever? Can the master and slave devices be switched dynamically as required?
In SPI bus communication, is it true that if a device is a master device, it can only be a master device forever, and if a device is a slave device, it can only be a slave device forever? Can the mast...
renfengee Embedded System
Suggestions on resolving issues affecting the normal use of automatic fire alarm systems
1. According to Article 18 of the Fire Protection Law of the People's Republic of China, "operators of automatic fire protection systems must be certified before they can take up their posts." That is...
aone2008 Industrial Control Electronics
Passionate competition day - see who is the best!
In order to liven up the atmosphere of communication among contestants in the [Contest Special Edition] https://bbs.eeworld.com.cn/forum-57-1.html , and to promote discussion of various problems encou...
EEWORLD社区 Electronics Design Contest

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2105  154  867  2420  2258  43  4  18  49  46 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号