EEWORLDEEWORLDEEWORLD

Part Number

Search

LTG-GC41L-PW-W-A/6V

Description
Rocker Switch, DPST, On-(off), Momentary, Solder Lug Terminal, Paddle Actuator, Panel Mount
CategoryMechanical and electronic products    switch   
File Size836KB,3 Pages
ManufacturerCarling Technologies
Download Datasheet Parametric View All

LTG-GC41L-PW-W-A/6V Overview

Rocker Switch, DPST, On-(off), Momentary, Solder Lug Terminal, Paddle Actuator, Panel Mount

LTG-GC41L-PW-W-A/6V Parametric

Parameter NameAttribute value
MakerCarling Technologies
Reach Compliance Codecompliant
Actuator colorWHITE
Actuator length0.26 inch
Actuator typePADDLE
body width25.2476 mm
Body colorWHITE
body height20.6248 mm
Body length or diameter28.448 mm
Contact (AC) maximum rated R load5A@250VAC
Maximum contact current (AC)5 A
Contact functionON-(OFF)
Maximum contact voltage (AC)250 V
Dielectric withstand voltage1000VRMS V
illuminationLAMP
Insulation resistance100000000 Ω
insulator materialNYLON
Manufacturer's serial numberLTG
Installation featuresPANEL MOUNT
surface mountNO
Switch actionMOMENTARY
switch functionDPST
Switch typeROCKER SWITCH
Terminal length0.375 inch
Termination typeSOLDER LUG

LTG-GC41L-PW-W-A/6V Preview

TG/LTG-Series
Rocker Switches
The TG-Series Mini Tippette rocker switches are single or double pole and feature an
all nylon double-insulated construction. These switches are designed with snap-in
mounting for fast, low cost assembly. The illuminated version (LTG) is available with
either a paddle or rocker actuator. These AC rated switches are also suitable for low-
voltage DC applications assuring compatibility for a wide range of markets including
Appliance, HVAC, Food service, and Transportation.
Carling Technologies, Inc.
60 Johnson Avenue • Plainville, CT 06062-1177
Phone: (860) 793-9281 • Fax: (860) 793-9231
Email: sales@carlingtech.com • www.carlingtech.com
2 | TG/LTG-Series Rocker Switches
Dielectric Strength
UL/CSA:
1000V - live to dead metal parts
Mechanical Life
100,000 cycles
Electrical Life
50,000 cycles - maintained
25,000 cycles - momentary
Operating Temperature
32°F to 185°F (0°C to 85°C)
1
Base Part Number
LTG G O 50 1
2
Circuit
3
Center
Position
4
Rating
5
Termination
6
Actuator
Style
T B
7
Actuator
Color
P
Paddle
8
Base Color
B
9
Lens Color
R / 125
10
Lamp Voltage
T
Rocker
1 BASE PART NUMBER: SERIES
TG
Double Pole, Non-Lighted
LTG
Double Pole with Indicator Lights
2 CIRCUIT
1
See Circuit Designation Chart.
3 CENTER POSITION
C
Center OFF, Three position
O
No Center OFF, Two position
4 RATING
40
5A 250VAC, 10A 125VAC, 1/2HP 125-250VAC
41
5A 250VAC, 10A 125VAC
50
10A 250VAC, 15A 125VAC, 3/4HP 125-250VAC
51
10A 250VAC, 15A 125VAC
5 TERMINATION/FUNCTION
Solder Lug .250 Tab QC
On-None-Off
0
1
(On)-None-Off
A
B
On-None-(Off)
L
M
On-None-On
0
1
On-None-(On)
A
B
On-Off-On
0
1
.187 Tab QC
3
D
R
3
D
3
Wire Leads
5
F
T
5
F
5
6 ACTUATOR STYLE
7 ACTUATOR COLOR
2
B
Black
W
White
8 BASE COLOR
2
B
Black
W
White
9 LENS COLOR
3
A
Amber
C
Clear
R
Red
10 LAMP VOLTAGE
incandescent
6V
6 volt
12V
12 volt
18V
18 volt
24V
24 volt
28V
28 volt
neon
125N
250N
125 volt neon
250 volt neon
Notes:
Imprinting is available. Consult factory.
Panel Cut-Out Recommendations: For sheet metal panels, switch must enter panel in same
direction as the punch. (Burr on bottom.) Test cut hole in actual material.
1
TG available with circuits A, B, C, D, E, F ; LTG available with circuits
G, H, I, J, M, N, P, Q, R, T, U, V, Y, Z.
2
Custom colors are available. Consult factory.
3
Specify lens color for LTG-Series only.
( ) Indicates momentary function.
.069[1.75] DIA
.156[3.96] DIA
.375[9.52]
.055[1.40] DIA
6.000[152.40]
.250[6.35]
.500[12.70]
INTEGRATED WIRE LEAD
(no exposed conductors)
1.155[29.33]
.865[21.97]
.050[1.27]
1.240[31.50]
.250[6.35]
.250 TAB (Q.C.)
.250[6.35]
SOLDER LUG
.187[4.74]
.187 TAB (Q.C.)
TERMINAL TYPE
.210[5.33]
.812[20.62]
.520[13.20]
1.125[28.57]
.375[9.52]
.994[25.24]
1.120[28.45]
PADDLE
1.000[25.40]
MOUNTING HOLE
Panel Thickness:
.030[.762] min. to
.250[6.35] max.
*Manufacturer reserves the right to change product specification without prior notice.
60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: sales
@
carlingtech.com • www.carlingtech.com
Circuit Designation Chart | 3
1
1
4
1
2
2
2
5
2
5
2
5
3
3
3
6
3
6
3
6
B
4
4
C
4
1
D
4
1
E
4
2
5
2
2
2
2
3
3
3
6
3
6
3
I
1
4
1
4
1
4
1
4
1
J
4
2
5
2
5
2
5
2
5
5
3
6
3
6
3
6
3
6
3
6
1
4
1
4
1
4
1
4
1
4
2
5
2
5
5
2
2
5
3
6
3
6
3
6
3
6
3
T
1
4
1
1
1
4
2
5
2
5
2
5
2
5
2
5
3
6
3
6
3
6
3
6
3
6
Z
CONTACT TERMINAL
Will make contact with switching lever
CONTACT TERMINAL AND SWITCH LEVER
BULB
REV_SW_TG/LTG_0912
ISOLATED TERMINAL
Does not make contact with switching lever
60 Johnson Avenue • Plainville, CT 06062–1177 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: sales
@
carlingtech.com • www.carlingtech.com
Platform Builder compilation error
Could you please help me find out what caused the error and how to solve it? This is a small part of the results displayed at the end: D:\WINCE500\build.err D:\WINCE500\build.log D:\WINCE500\build.wrn...
daymare Embedded System
PB5.0 cannot generate eboot.nb0 file
My work machine is XP professional + sp2, and PB5.0 is installed. However, when I create a new PB project and compile it successfully, no eboot.nb0 file is generated. However, the same operation can g...
amw196209 Embedded System
Is this going against the will of heaven?! A cremator born in the 1980s wrote a book, which became a "super heavy taste book"
Crematorium, a place that sounds mysterious and scary, cremator, a special profession that makes people feel a chill in their hearts, but many people are full of curiosity about it.     Recently, a do...
阴阳怪气 Talking
How to realize directory transfer display by file filter driver
How to implement in file filter driver: when opening folder A, display all files in folder A and folder B? I feel that PFILE_BOTH_DIR_INFORMATION in SfDirectoryControl cannot achieve the function I wa...
shinecx2 Embedded System
Some concepts and modulation methods of wireless radio frequency
RF, IF, basebandRF signal refers to the unmodulated carrier signal; IF signal refers to the lower IF signal after heterodyne transformation of RF signal. The purpose of using IF is to facilitate ampli...
Jacktang RF/Wirelessly
Design of a PCB loop antenna in RFID system
This paper implements the design of a PCB ring antenna in RFID system. Based on the analysis of the working principle of the antenna, the design method of the antenna based on the 13.56 MHz, 200 mw lo...
xtss RF/Wirelessly

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 376  135  565  1052  2086  8  3  12  22  42 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号