TMA250-36

Description
250W Medical Power Adapters
File Size130KB,1 Pages
ManufacturerTRUMPower
Websitehttp://www.trumpower.com/
Download Datasheet Compare View All

TMA250-36 Overview

250W Medical Power Adapters

TMA250 Series
TRUMPower
FEATURES
90~264 VAC Universal Input
250W Continuous Power
0.9 Active Power Factor
Thermally-Controlled Cooling Fan
No Load Power Consumption < 0.5W
250W Medical Power Adapters
ELECTRICAL SPECIFICATIONS
Input Voltage ................................... 90~264 VAC
Input Frequency .............................. 47~63 Hz
Input Current .................................. 3.5A (rms) @ 90 VAC,
1.5A (rms) max. @ 264 VAC
Earth Leakage Current .................. 228μA max. @ 264 VAC
Power Factor .................................. 0.9 min. at full load,
115 VAC/230 VAC
No Load Power Consumption ....... 0.5W max.
Output Voltage, 12V~48V ............... CEC & Energy Star Level V
Output Current ................................ See table
Output Power .................................. 250W
Voltage Regulation ......................... ±5%
Ripple and Noise ........................... See table
STANDARDS & COMPLIANCES
EMC Standards ..................... EN60601-1-2, EN55011 Class B,
FCC Part 18 Class B
Safety Standards ................... UL60601-1, EN60601-1,
CSA C22.2 No. 60601-1,
IEC60601-1
Agency Approvals .................. UL, cUL, TUV, CB, CE
Other Compliances .............. RoHS, CEC Level V,
Energy Star Level V
MODELS LIST
Product N o.
TMA250-12
TMA250-16
TMA250-19
TMA250-20
TMA250-24
TMA250-36
TMA250-48
Output
Voltage
12V
16V
19V
20V
24V
36V
48V
Output
C urrent
20.83A
15.63A
13.16A
12.5A
10.42A
6.94A
5.21A
R ipple &
N oise (Vp-p)*
240mV
300mV
300mV
300mV
300mV
300mV
300mV
Max. Output
P o w er
250W
250W
250W
250W
250W
250W
250W
GENERAL SPECIFICATIONS
Efficiency ............................. 87% min. at avg. load,
115/230 VAC
Switching Frequency ........... 60~65KHz
Hold-up Time ...................... 16ms min. typical at full load, 115 VAC
Operating Temperature ...... -20°C to +40°C
Storage Temperature .......... -20°C to +85°C
Operating Humidity ............. 10% to 95%
Short-Circuit Protection ....... Auto-recovery
Over-Load Protection .......... Auto-recovery
Over-Voltage Protection ...... Latch, AC recycle
Withstand Voltage ............... 5656VDC from input to output
2121VDC from input to ground
MTBF .................................... 140K hrs minimum at full load
and 25°C ambient, calculated
per MIL-HDBK-217F
* Peak-to-peak with 20MHz bandwidth with a tantalum 10μF in parallel with 0.1μF
ceramic capacitor.
OUTPUT CONNECTORS & PINOUTS
APP C ON N EC TOR
C OLOR
R ED
WH ITE
B LAC K
B LU E
D .W
FU N C TION
+Vo
+Vo
GND
GND
GND
MECHANICAL SPECIFICATIONS
6-PIN C ON N EC TOR
PIN
1
2
3
4
5
6
FU N C TION
GND
GND
GND
+V
+V
+V
6
5
4
3
2
1
Notes:
1. Dimensions: mm
2. AC Inlet: IEC320/C14 standard
3: Tolerance: ±0.5mm
4. Standard Output Cable: AWM 2464 #16AWG/6C + Shielding, UL 80°C 300V
VW-1, 1000±30mm min. for 16V~48V output; 800±30mm for 12V output.
5. Weight: 1060 grams
Notes:
1. Output Connector: Molex Mini-Fit 6-pin connector, P/N 39-01-2060 or equivalent
2. Mating Connector: Molex P/N 39-01-2061 or equivalent
3. Add suffix "A" to the P/N to order units furnished with APP connector.
4. Contact TRUMPower for other output connector options.
#TMA250-2011-0701
Tumbler Technologies + TRUMPower
3350 Scott Blvd., Building 13 • Santa Clara, California 95054, USA
408-988-6616
sales@trumpower.com • www.TRUMPower.com

TMA250-36 Related Products

TMA250-36 TMA250-12 TMA250-19 TMA250-24 TMA250 TMA250-16 TMA250-20 TMA250-48
Description 250W Medical Power Adapters 250W Medical Power Adapters 250W Medical Power Adapters 250W Medical Power Adapters 250W Medical Power Adapters 250W Medical Power Adapters 250W Medical Power Adapters 250W Medical Power Adapters
The first test code for LPC1343 under LPCXpresso v3.2
There is an LED on the board, and the LED flashing is achieved by modifying the GPIO routine under LPCXpresso v3.2. Briefly introduce the usage and upload the code....
莫恩 NXP MCU
Keithley SourceMeter - One Test Instrument Compares to Five
From 1989 when Keithley invented the digital source meter to the present day, Keithley source meters have a market share of 80% , making them a major brand in the source meter market. Over the past tw...
agitek2017 Test/Measurement
Problems with installing eclipse under linux
I installed JDK, as shown in the picture:I also installed SDK, as shown in the picture:But after installing eclipse, an error occurred: As shown in the picture:Can any experts tell me how to solve thi...
chenbingjy Linux and Android
LM chip top mark
...
hlx3012 Microcontroller MCU
A newbie has a question about uCOS.
I would like to ask if the method of writing HEX files to the chip is the same as that of writing uCOS? How does uCOS work?...
saybey Real-time operating system RTOS

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2849  2690  2002  2789  1063  58  55  41  57  22 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号