DP0V-2FBA_14

Description
DP0V (100 psi / 7 bar) pump,
File Size317KB,1 Pages
ManufacturerRalston Instruments
Websitehttps://www.ralstoninst.com/
Download Datasheet View All

DP0V-2FBA_14 Overview

DP0V (100 psi / 7 bar) pump,

Part No.
DP0V-2FBA
DP0V (100 psi / 7 bar) pump, 1/4" female NPT gauge adapter,
3ft hose, 1/4" MNPT process conn.
Perform very precise low pressure calibration
or differential pressure calibration using an
attached gauge or calibrator (gauge and
calibrator not included)
Features
• Light weight, compact pump generates up to 125 psi (8.6 bar)
with ease
• Large volume fine adjustment piston provides precise control,
even at very low pressures
• Modular design makes field maintenance quick and easy
• Precisely vent pressure with soft seated bleed valve
• Two outlet ports provide connections for both pressure
reference and for device under test thus eliminating a tee
• Low volume Quick-test hose, gauge adapter and process
connection can be attached to pump without thread sealant
or a wrench
• Rugged, all metal construction reduces pressure changes
due to temperature fluctuations
• Made in U.S.A.
DP0V-2FBA
Item Includes
• Hand Pump - DP0V Assembly (DP0V)
• Gauge Adapter - 1/4" female NPT x female Quick-test, no check-valve, brass (QTHA-2FBA)
• Hose - Quick-test 6900 psi hose, brass hose ends, 3 ft (92 cm) long (QTQT-HOS-3ft)
• Hose Adapter - 1/4" male NPT x male Quick-test, no check-valve, brass (QTHA-2MB0)
Specifications
Pressure Range
Media
Outlet Port1
Outlet Port2
Temperature Range
Construction
Seal Materials
Fine Adjust Resolution
Weight
Dimensions
0 to 125 psi (0 to 9 bar)
Air
Male Quick-test outlet port, no check-valve, brass
Male Quick-test outlet port with cap and chain, brass
0 to 130 °F (-18 to 54 °C)
Anodized Aluminum, Brass, Stainless Steel
Buna-N, Delrin, Teflon
±0.01 psi
1.61 lb (0.7 kg)
H: 2.87 in (7.2898 cm) x W: 7.93 in (20.1422 cm) x D: 3.5 in (8.89 cm)
Ralston Instruments Inc. | ralstoninst.com | Toll Free 800-347-6575 | Phone 440-564-1430 | Fax 440-564-1480
Simulation software consulting
Does anyone know how to perform hardware simulation on FPGA/CPLD? That is, use MAX+plush2 to generate .pof/.sof files, and then use software hardware simulation. Does anyone know of such software?...
eeleader FPGA/CPLD
gossip
I would like to ask how are the dormitory relations in college? I personally think that boys may be better, while girls are worse. right?...
duxiaowen Embedded System
Introduction to the e-sports competition evaluation process
[i=s]This post was last edited by paulhyde on 2014-9-15 03:29[/i] [align=center][size=4][b]Brief introduction to the electronic competition process[/b][/size][/align] [align=left][size=4] I'm new here...
干磨河 Electronics Design Contest
Mifare Standard IC Card MF1 IC S50 Functional Specification
Philips developed the wireless smart card chip Mifare? MF1 IC S50 according to ISO/IEC 14443A standard. The communication layer of this chip Mifare? RF interface complies with Part 2 and Part 3 of ISO...
rain Test/Measurement
Actions recruitment analog design engineer written test questions
Actions recruitment analog design engineer written test questions...
analogstudy Analog electronics
RT9293B is used for VGH/VGL of 7-inch screen
As the title says, VGH=18V VGL=-8V, can this IC achieve this?...
jplzl10000 LED Zone

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1779  698  2172  2806  1418  36  15  44  57  29 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号