RF Coaxial Relay, SPDT, Failsafe, 57500mW (Coil), 4000MHz, AC Input, AC Output, Panel Mount,
CategoryMechanical and electronic products    relay   
File Size96KB,1 Pages
ManufacturerRLC Electronics Inc
Download Datasheet Parametric View All

SMP-2-H-A-TL Overview

RF Coaxial Relay, SPDT, Failsafe, 57500mW (Coil), 4000MHz, AC Input, AC Output, Panel Mount,

SMP-2-H-A-TL Parametric

Parameter NameAttribute value
MakerRLC Electronics Inc
Reach Compliance Codeunknown
ECCN codeEAR99
Other featuresBUILT-IN TTL DRIVER
body width26.16 mm
body height54.86 mm
Body length or diameter89.92 mm
Characteristic impedance50 Ω
Coil current (AC) maximum value0.5 A
Coil power57500 mW
Maximum coil voltage (AC)115 V
Coil/Input Power TypeAC
Contact/Output Power TypeAC
Electrical life1000000 Cycle(s)
Maximum insertion loss0.2 dB
Maximum isolation60 dB
Manufacturer's serial numberSMP
Installation featuresPANEL MOUNT
Maximum operating frequency4000 MHz
Minimum operating frequency
physical size89.92mm X 26.16mm X 54.86mm
Relay actionFAILSAFE
Relay functionSPDT
Relay typeRF COAXIAL RELAY
surface mountNO
switching time20 ms
Termination typeCONNECTOR
voltage standing wave ratio1.25
High Power Coaxial Switches
RLC Electronics' High Power Coaxial Switch is a single pole,
two position type providing extremely high reliability, long life
and excellent electrical performance over the frequency range
of DC-6 GHz. The switches will handle 2000 Watts at 100 MHz
to 400 Watts at 6 GHz. The switches utilize thermally conductive,
dielectric insulators to allow high power handling capabilities.
The package utilizes high density packaging techniques, volume
of the switch is less than 6 cubic inches.
Specifications
S
1
P-2
-2-3-4-5-6
Switch Type
Frequency Range
DC-4.0
Insertion Loss (Max dB)
VSWR (Max)
Isolation (dB)
0.2
1.25
60
SINGLE POLE TWO POSITION
DC-6 GHz
4.0-6.0
0.5
1.5
60
Power Rating, RF Cold Switching:
See page 5.
Impedance:
50 Ohms/75 Ohms.*
Operating Power 25°C:
(Failsafe):
12Vdc at 575 ma nom. 28Vdc at
200 ma nom. 115 Vac at 50 ma nom.
(Latching):
12 Vdc at 1 amp nom. 28 Vdc at
430 ma nom. 115 Vac at 50 ma nom. Current
applied 10 ms min. cutthroat circuitry(standard),
recovery time 100 ms nom.
Connectors, RF:
N, SC, HN, TNC, Female
(HN not recommended for use above 4GHz)
Connectors, Power:
Feed through solder lugs.
Life:
1,000,000 operations.
Switching Time:
20 mS Max.
Weight:
12 oz.
Environmental Conditions:
MIL-S-3928
Operating Mode:
Manual, failsafe or latching.
Switching Sequence:
Break before make.
*75 ohm up to 3 GHz.
To designate the switch desired use:
(1) “M” for Manual, “R” for Remote.
(2) “S” for SC, “H” for HN, “N” or “T” for TNC
(3) “A” for 115 Vac, “D” for 28 Vdc or “H” for 12 Vdc.
(4) “I” for indicators if desired.
(5) “L” for latching cutthroat if desired.
(6) “TL” for TTL Driver if desired
Example: SRP-2-S-D-I is a remote, SC Connectors, 28 Vdc; with indicators, Failsafe operation switch 50 ohms
for 75 ohms SRP75-2- - -
Outline Drawing
RLC ELECTRONICS, INC.
83 Radio Circle, Mount Kisco, New York 10549 • Telephone: 914-241-1334 • Fax: 914-241-1753
e-mail: sales@rlcelectronics.com • www.rlcelectronics.com
13
LIN Communication Problems
When debugging LIN communication, I found that the value of the transmit data register (LINTDy) is the same as the value of the receive data register (LINRDy). Is this normal? In addition, when using ...
喜鹊王子 TI Technology Forum
IAR MSP430 compilation error description
Unnumbered warning type: 1. Sat Jun 23, 2012 17:41:05: The stack pointer for stack 'Stack' (currently Memory:0xF5336) is 0xF5336. IAR related settings: Tools->Option->Stack->Warn when stack pointer is...
fish001 Microcontroller MCU
ucosiii help
In the process of modifying cpu_a.s, I encountered the following and didn't know how to modify it. /****************************************************************************************************...
maxiang615 Real-time operating system RTOS
How is the ADS configuration file .HFC generated?
:D May I ask all the experts, how is the ADS configuration file .HFC generated? Using IAR seems to be .ICF file, what is the function of this thing?...
zhangbinkui818 Embedded System
Do you have experience using the table lookup method to calculate the trigonometric function atan?
Do you have experience in using the lookup table method to calculate the trigonometric function atan? In hardware design, the table method is often used to calculate sin and cos. I don't know how to c...
guge8079 Embedded System
About the Thermistor on the Ferroelectric MSP-EXP430FR5739
Is there any information about the thermistor on the Ferroelectric MSP-EXP430FR5739? For example, the B value or something? Has anyone used the thermistor mentioned above in detail? How accurate can t...
wangfuchong Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 149  1685  209  2540  1534  3  34  5  52  31 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号