EEWORLDEEWORLDEEWORLD

Part Number

Search

306E-710-3006

Description
Board Connector, 10 Contact(s), 1 Row(s), Male, Straight, 0.156 inch Pitch, Solder Terminal, Natural Insulator, Receptacle
CategoryThe connector    The connector   
File Size153KB,1 Pages
ManufacturerMethode Electronics Inc.
Download Datasheet Parametric View All

306E-710-3006 Overview

Board Connector, 10 Contact(s), 1 Row(s), Male, Straight, 0.156 inch Pitch, Solder Terminal, Natural Insulator, Receptacle

306E-710-3006 Parametric

Parameter NameAttribute value
MakerMethode Electronics Inc.
Reach Compliance Codeunknown
ECCN codeEAR99
Other featuresPOLARIZED
Board mount optionsPCB EDGE LOCKING HOOK
subject depth0.45 inch
body length1.554 inch
Body/casing typeRECEPTACLE
Connector typeBOARD CONNECTOR
Contact to complete cooperationSN-PB ON NI
Contact completed and terminatedTIN/LEAD OVER NICKEL
Contact point genderFEMALE
Contact materialPHOSPHOR BRONZE
contact modeRECTANGULAR
Contact resistance5 mΩ
Contact styleSQ PIN-SKT
DIN complianceNO
Dielectric withstand voltage1500VAC V
Filter functionNO
IEC complianceNO
maximum insertion forceLIF N
Insulation resistance500000000000 Ω
Insulator colorNATURAL
insulator materialNYLON
MIL complianceNO
Plug contact pitch0.156 inch
Plug informationMULTIPLE MATING PARTS AVAILABLE
Mixed contactsNO
Installation methodSTRAIGHT
Installation typeBOARD
Number of connectorsONE
PCB row number1
Number of rows loaded1
Maximum operating temperature105 °C
Minimum operating temperature-40 °C
OptionsGENERAL PURPOSE
PCB contact patternRECTANGULAR
polarization keyPOLARIZED KEY
Rated current (signal)7 A
GuidelineUL, CSA
reliabilityCOMMERCIAL
Terminal length0.125 inch
Terminal pitch3.96 mm
Termination typeSOLDER
Total number of contacts10
UL Flammability Code94V-0
Evacuation force-minimum valueLIF N
.156” (3.96mm)
Through Hole Vertical Mount Connector
3000 SERIES “TERMACON”
PART NUMBER LEGEND
30XX-XXX-XXXX
CONTACT TAIL DIMS (SEE TABLE 2)
CONTACT MATERIAL (SEE NOTE 1)
OPTIONS
2 - HIGH INSERTION FORCE CONTACT
3 - LOW INSERTION FORCE CONTACT
NO. OF POSITONS (SEE TABLE 1)
OPTIONS
0-
1-
3-
6-
7-
8-
WITH LEGS
WITH HOOKS
WITH HOOKS AND LOCKING RAMP
WITH LOCKING RAMP
WITH HOOKS, LOCKING RAMP AND POLARIZING KEY
WITHOUT HOOKS, W/ LOCKING RAMP AND POLARIZING KEY
CONTACT FINISH (SEE NOTE 2)
INSULATOR MATERIAL (SEE NOTE 1)
MATING HEADERS: 3100 SERIES
HOLE
LEG
LOCKING
RAMP
POLARIZING KEY &
LOCKING RAMP
Connector Products
1700 Hicks Road • Rolling Meadows, IL 60008 USA
Telephone: 847.392.3500 • Fax: 847.392.9404
email: mcpsales@methode.com • Web Page: www.methode.com
【R7F0C809】Simple concentration detection instrument (software part) adds pulse measurement part
[i=s] This post was last edited by cat3902982 on 2015-11-25 01:46 [/i] The simple concentration detection instrument (software part) has added a pulse measurement part. The CLK clock measurement is ma...
cat3902982 Renesas Electronics MCUs
Search for ECD-51 development machine!!!
[size=5]Hello, I am looking for an old single-chip development machine ECD-51. If anyone is willing to give it to me, please contact me on QQ: 287477745. I would like to thank you very much! [/size]...
lubo_bbc 51mcu
Chongqing engineering boy pursues girl and makes resistor bracelet to "say" love you
The total value of the resistors on the bracelet is 24640 ohms, and the invisible resistor decorated with small beads is 13140 ohms. Among them, 2464 is typed in the mobile phone grid, which means "ai...
funnylogic Talking
LM2970 related information
[i=s] This post was last edited by paulhyde on 2014-9-15 09:01 [/i] LM2970 related information...
yanghaibo1121 Electronics Design Contest
DIY Tips + Capacitor Leakage Current Meter
Project title: Capacitor leakage current measuring instrument Project goal: To measure the leakage current of capacitors with a withstand voltage below 30V Basic block diagram of the project:Project d...
wstt ADI Reference Circuit
10. [Learning LPC1768 library functions] Timer capture experiment
LPC1768 has 4 timers, which can be used as interval timers, external capture inputs, and free-running timers. At least 2 of the 4 timers can be set as capture and match outputs, and timer 2 can be set...
cxmdz NXP MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 529  1458  1703  2007  2324  11  30  35  41  47 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号