General Purpose Inductor, 0.036uH, 2%, 1 Element, Ceramic-Core, SMD, CHIP
CategoryPassive components    inductor   
File Size372KB,2 Pages
ManufacturerTOKO, INC.
Websitehttps://www.murata.com/
Download Datasheet Parametric View All

LLQ1608-A36NG Overview

General Purpose Inductor, 0.036uH, 2%, 1 Element, Ceramic-Core, SMD, CHIP

LLQ1608-A36NG Parametric

Parameter NameAttribute value
Is it lead-free?Contains lead
Is it Rohs certified?incompatible
MakerTOKO, INC.
Reach Compliance Codeunknown
ECCN codeEAR99

LLQ1608-A36NG Preview

22
TYPE
LLQ1608
Wirewound Chip Inductors
Meeting Your Needs
1.8 max.
0.86
0.33
0.76
0.38
1.02
Unit: mm
Tolerance:
±0.1mm
Features
• Inductance tolerance:
±2%, ±5%, ±10%
• EIA standard 0603 footprint (1.6mm x 0.8mm)
• High Q
• High self-resonant frequency
• Operating temperature: –40°C to +125°C
• Packaged on tape and reel in 3,000 piece quantity
• Reflow solderable
Part Numbering
LLQ 1608 - A 1N6 J
Tolerance
(G=±2%, J=±5%, K=±10%)
Inductance
Material
Dimensions (LxW)
Type Name
ELECTRICAL CHARACTERISTICS
Q vs Frequency
120
100
R12 (120 nH)
80
60
40
20
0
10
100
1000
Frequency (MHz)
68N (68 nH)
33N (33 nH)
22N (22 nH)
12N (12 nH)
3N9 (3.9 nH)
Q
10000
Inductance vs Frequency
1000
Inductance (nH)
R12 (120 nH)
100
68N (68 nH)
33N (33 nH)
22N (22 nH)
10
12N (12 nH)
3N9 (3.9 nH)
1
10
100
1000
Frequency (MHz)
10000
1.800.PIK.TOKO
www.tokoam.com
1.847.297.0070
R-LOG0703A
0.64
0.64
0.64
The TOKO LLQ1608 Series is a wirewound ceramic chip inductor
that conforms to the EIA standard 0603 footprint and delivers
superb Q and SRF performance with high inductance tolerance.
Dimensions
1.12 max.
1.02 max.
Recommended
Footprint
0.33
Wirewound Chip Inductors
Meeting Your Needs
TYPE
LLQ1608
23
STANDARD PARTS SELECTION GUIDE
TYPE LLQ1608
TOKO
Part Number
LLQ1608-A1N6_*
LLQ1608-A1N8_*
LLQ1608-A3N6_*
LLQ1608-A3N9_*
LLQ1608-A4N3_*
LLQ1608-A4N7_*
LLQ1608-A5N1_*
LLQ1608-A6N8_*
LLQ1608-A7N5_*
LLQ1608-A8N7_*
LLQ1608-A9N5_*
LLQ1608-A10N_*
LLQ1608-A11N_*
LLQ1608-A12N_*
LLQ1608-A15N_*
LLQ1608-A16N_*
LLQ1608-A18N_*
LLQ1608-A22N_*
LLQ1608-A24N_*
LLQ1608-A27N_*
LLQ1608-A30N_*
LLQ1608-A33N_*
LLQ1608-A36N_*
LLQ1608-A39N_*
LLQ1608-A43N_*
LLQ1608-A47N_*
LLQ1608-A56N_*
LLQ1608-A68N_*
LLQ1608-A72N_*
LLQ1608-A82N_*
LLQ1608-AR10_*
LLQ1608-AR11_*
LLQ1608-AR12_*
LLQ1608-AR15_*
LLQ1608-AR18_*
LLQ1608-AR22_*
LLQ1608-AR27_*
Inductance
Q (min.)
Lo (nH)
1.6
1.8
3.6
3.9
4.3
4.7
5.1
6.8
7.5
8.7
9.5
10
11
12
15
16
18
22
24
27
30
33
36
39
43
47
56
68
72
82
100
110
120
150
180
220
270
Tolerance
J, K
J, K
J, K
J, K
J, K
J, K
J, K
G, J, K
G, J, K
G, J, K
G, J, K
G, J, K
G, J, K
G, J, K
G, J, K
G, J, K
G, J, K
G, J, K
G, J, K
G, J, K
G, J, K
G, J, K
G, J, K
G, J, K
G, J, K
G, J, K
G, J, K
G, J, K
G, J, K
G, J, K
G, J, K
G, J, K
G, J, K
G, J, K
G, J, K
G, J, K
G, J, K
24
16
22
22
22
20
20
27
28
28
28
31
33
35
35
34
35
38
37
40
37
40
38
40
39
38
38
37
34
34
34
32
32
28
25
25
24
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
250
200
200
200
150
150
150
150
150
150
100
100
100
Test Frequency
MHz
Self Resonant
Frequency (MHz)
min.
12500
12500
5900
6900
5900
5800
5700
5800
4800
4600
5400
4800
4000
4000
4000
3300
3100
3000
2650
2800
2250
2300
2080
2200
2000
2000
1900
1700
1700
1700
1400
1350
1300
990
990
900
900
DC
Resistance
(
) max.
0.030
0.045
0.063
0.080
0.063
0.116
0.140
0.110
0.106
0.109
0.135
0.130
0.107
0.130
0.170
0.134
0.170
0.190
0.161
0.220
0.187
0.220
0.250
0.250
0.280
0.280
0.310
0.340
0.490
0.540
0.580
0.610
0.720
0.920
1.25
2.10
2.30
IDC
(mA)
max.
700
700
700
700
700
700
700
700
700
700
700
700
700
700
700
700
700
700
700
600
600
600
600
600
600
600
600
600
400
400
400
300
300
280
240
200
170
* Add tolerance to part number: G =
±2%,
J =
±5%,
K =
±10%
Testing Conditions: L,Q: Agilent 4287A (Test fixture Agilent 16193A).
R-LOG0703A
SRF: Agilent 8720ES.
RDC: Agilent 34420A.
IDC: Agilent 34401A.
1.847.297.0070
1.800.PIK.TOKO
www.tokoam.com
Module selection and application of medical power supply
In today's society, with the continuous advancement of science and technology, more and more contemporary medical devices have been rapidly developed, especially electronic instruments that are in dir...
8023jiayun Medical Electronics
[micropython tutorial] +4 SPI drive OLED display success
I saw many people driving OLED using I2C, but the OLED module I had was already soldered with SPI, so I tried to drive it using SPI. . . . I referred to [color=#333333][size=3]ESP8266 SPI Drive OLED[/...
飞扬自我 MicroPython Open Source section
Stack buffer overflow?
Stack buffer overflow? What is the difference between this stack buffer overflow and stack overflow?...
l0700830216 Programming Basics
Anyone who knows RIL please help me!!!
Hey guys, after my RIL is running, none of the commands I send are successfully returned, all of them are TIMEOUT. But when I don't load RIL, I get a response when I use an application to write comman...
beishui Embedded System
Use dimensioning to accurately place components and frames
In our common understanding, dimensioning is mostly used in PCB production and welding assembly files to mark the size of components and borders. Generally, in the design process, it is customary to p...
okhxyyo PCB Design
Excuse me, what does st(x) do { x } while (__LINE__ == -1) mean in the protocol stack?
As the title says, what does __LINE__ mean?...
weiruiqi120 RF/Wirelessly

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 862  330  1071  2010  1725  18  7  22  41  35 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号