BCM53106SIFBG

Description
Ethernet Transceiver,
CategoryWireless rf/communication    Telecom circuit   
File Size2MB,146 Pages
ManufacturerBroadcom
Environmental Compliance
Download Datasheet Parametric Compare View All

BCM53106SIFBG Online Shopping

Suppliers Part Number Price MOQ In stock  
BCM53106SIFBG - - View Buy Now

BCM53106SIFBG Overview

Ethernet Transceiver,

BCM53106SIFBG Parametric

Parameter NameAttribute value
Is it Rohs certified?conform to
MakerBroadcom
package instructionFBGA-212
Reach Compliance Codecompliant
JESD-30 codeS-PBGA-B212
length11 mm
Humidity sensitivity level3
Number of functions1
Number of terminals212
Maximum operating temperature85 °C
Minimum operating temperature-45 °C
Package body materialPLASTIC/EPOXY
encapsulated codeTFBGA
Package shapeSQUARE
Package formGRID ARRAY, THIN PROFILE, FINE PITCH
Peak Reflow Temperature (Celsius)NOT SPECIFIED
Maximum seat height1.017 mm
Nominal supply voltage1 V
surface mountYES
technologyCMOS
Telecom integrated circuit typesETHERNET TRANSCEIVER
Temperature levelINDUSTRIAL
Terminal formBALL
Terminal pitch0.65 mm
Terminal locationBOTTOM
Maximum time at peak reflow temperatureNOT SPECIFIED
width11 mm

BCM53106SIFBG Preview

Data Sheet
BCM53106S
Multiport Ultra Low-Power Ethernet Switches
GE NERA L DESCR IPTI O N
The Broadcom
®
BCM53106S is an ultra low-power, highly
integrated, cost-effective smart Fast Ethernet switch. The
switch design is based on the field-proven, industry-leading
ROBO architecture. This device combines all the functions
of a high-speed switch system including packet buffers,
PHY transceivers, media access controllers (MACs),
address management, port-based rate control, and a
nonblocking switch fabric into a single 28 nm CMOS device.
Designed to be fully compliant with the IEEE 802.3 and
IEEE 802.3x specifications, including the MAC-control
PAUSE frame, the BCM53106S provides compatibility with
all industry-standard Ethernet and Fast Ethernet devices.
The BCM53106S has a rich feature set suitable for not only
standard Fast Ethernet connectivity for broadband home
gateways, desktop and laptop PCs, but also for next-
generation gaming consoles, set-top boxes, networked
DVD players, and home theater receivers. It is also
specifically designed for next generation SOHO/SMB
routers and gateways.
The BCM53106S contains four full-duplex 10/100BASE-TX
Ethernet transceivers. In addition, the BCM53106S has two
PHY-less interfaces for the CPU or a router chip, providing
flexible 10/100 Mbps connectivity. One RGMII interface can
be connected to a CPU entity and configured as an IMP (In
Band Management port).
The second RGMII interface is available for another PHY,
Modem, or CPU connection.
The BCM53106S provides 70+ on-chip MIB counters to
collect receive and transmit statistics for each port.
The BCM53106S is available in industrial temperature (I-
Temp) and commercial temperature (C-Temp) rated
packages. The BCM53106S is available in one package
type, a 212-pin FBGA package.
F EA T U R E S
Four 10/100M and two 10/100/1000M media access
controllers
Four-port 10/100 transceivers for TX
One RGMII interface for an inband management port
(IMP) for connection to a CPU/management entity
without PHY
One RGMII interface for a connection to another PHY,
CPU, or Modem.
IEEE 802.1p, MAC Port, TOS, and DiffServ QoS for six
queues, plus two time sensitive queues
Port-based VLAN
IEEE 802.1Q-based VLAN with 4K entries
MAC-based trunking with automatic link failover
Port-based rate control
Port mirroring (Ingress/Egress)
Supports IPv4 and IPv6
Priority modification on egress
BroadSync
®
HD for IEEE 802.1AS support
Timestamp tagging at MAC interface
Time-aware egress scheduler
DOS attack prevention
IGMP Snooping, MLD snooping support
Spanning tree support (multiple spanning trees–up to
eight)
Embedded CPU (8051) processor for cable
diagnostics.
CableChecker
with unmanaged mode support
Double tagging/QinQ
IEEE802.az Energy Efficient Ethernet (EEE) support
IEEE 802.3x programmable per-port flow control and
backpressure, with IEEE 802.1X support for secure
user authentication
EEPROM, MDC/MDIO, and SPI Interface.
Serial Flash Interface for accessing embedded CPU
(8051)
4K entry MAC address table with automatic learning
and aging
128 KB packet buffer (1 KB = 1024 bytes)
128 multicast group support
Jumbo frame support up to 9720 byte
1.0V for core and 3.3V for I/O
RGMII with option of 2.5V or 1.5V
JTAG support
212-pin FBGA package
53106S-DS103-R
Corporate Headquarters: San Jose, CA
September 12, 2016
BCM53106S Data Sheet
Revision History
Figure 1: BCM53106S Functional Block Diagram
TDP/N_0_[1:0]
10/100 PHY
GMAC
TDP/N_1_[1:0]
10/100 PHY
GMAC
Registers
TDP/N_2_[1:0]
10/100 PHY
GMAC
Packet Buffer MMU
TDP/N_3_[1:0]
10/100 PHY
GMAC
Address
Management
RGMII
GMAC
LED Interface
LED
8051 Micro
Controller
RGMII
GMAC
EEPROM/SPI
Interface
Flash
Memory
EEPROM/
CPU
Broadcom
®
September 12, 2016 • 53106S-DS103-R
Page 2
BROADCOM CONFIDENTIAL
Revision History
Revision
53106S-DS103-R
Date
09/12/16
Change Description
Updated:
Table 29: “Pin Lit by Pin Number,” on page 115
53106S-DS102-R
53106S-DS101-R
53106S-DS100-R
08/12/16
02/24/16
07/09/15
Updated:
Table 33: “Electrical Characteristics,” on page 130
Updated:
• Table 33: “Signal Descriptions,” on page 123
Initial release.
© 2016 by Broadcom. All rights reserved.
Broadcom
®
, the pulse logo, Connecting everything
®
, Avago Technologies, and the A logo are among the
trademarks of Broadcom and/or its affiliates in the United States, certain other countries and/or the EU. The
term “Broadcom” refers to Broadcom Limited and/or its subsidiaries. For more information, please visit
www.broadcom.com.
Broadcom reserves the right to make changes without further notice to any products or data herein to improve
reliability, function, or design. Information furnished by Broadcom is believed to be accurate and reliable.
However, Broadcom does not assume any liability arising out of the application or use of this information, nor
the application or use of any product or circuit described herein, neither does it convey any license under its
patent rights nor the rights of others.
This data sheet (including, without limitation, the Broadcom component(s) identified herein) is not designed,
intended, or certified for use in any military, nuclear, medical, mass transportation, aviation, navigations,
pollution control, hazardous substances management, or other high-risk application. BROADCOM
PROVIDES THIS DATA SHEET “AS-IS,” WITHOUT WARRANTY OF ANY KIND. BROADCOM DISCLAIMS
ALL WARRANTIES, EXPRESSED AND IMPLIED, INCLUDING, WITHOUT LIMITATION, THE IMPLIED
WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, AND NON-
INFRINGEMENT.
BCM53106S Data Sheet
Table of Contents
Table of Contents
About This Document
................................................................................................................................ 13
Purpose and Audience .......................................................................................................................... 13
Acronyms and Abbreviations................................................................................................................. 13
Document Conventions ......................................................................................................................... 13
References ............................................................................................................................................ 14
Technical Support
...................................................................................................................................... 14
Section 1: Introduction ..................................................................................................... 15
Overview......................................................................................................................................................
15
Audience
..................................................................................................................................................... 16
Data Sheet Information
.............................................................................................................................. 16
Section 2: Features and Operation .................................................................................. 17
Overview......................................................................................................................................................
17
Quality of Service and Scheduling
........................................................................................................... 18
CoS Mapping......................................................................................................................................... 21
SF3 Egress Queues and Scheduler...................................................................................................... 21
Egress Transmit Queues ............................................................................................................... 21
Scheduler ....................................................................................................................................... 23
Scheduling............................................................................................................................................. 25
Leaky Bucket Shaper ............................................................................................................................ 26
Port-Based VLAN........................................................................................................................................
27
IEEE 802.1Q VLAN......................................................................................................................................
27
IEEE 802.1Q VLAN Table Organization................................................................................................ 28
Double-Tagging
.......................................................................................................................................... 28
ISP Port ................................................................................................................................................. 29
Customer Port ....................................................................................................................................... 29
Uplink Traffic (from Customer Port to ISP)............................................................................................ 30
Downlink Traffic (from ISP to Customer Port) ....................................................................................... 30
Jumbo Frame Support
............................................................................................................................... 31
Port Trunking/Aggregation........................................................................................................................
31
WAN Port.....................................................................................................................................................
32
Rate Control
................................................................................................................................................ 32
Ingress Rate Control ............................................................................................................................. 32
Two-Bucket System .............................................................................................................................. 33
Egress Rate Control .............................................................................................................................. 34
Bucket Bit Rate...................................................................................................................................... 34
Protected Ports...........................................................................................................................................
34
Broadcom
®
September 12, 2016 • 53106S-DS103-R
Page 4
BROADCOM CONFIDENTIAL
BCM53106S Data Sheet
Table of Contents
Port Mirroring..............................................................................................................................................
35
Enabling Port Mirroring.......................................................................................................................... 35
Capture Port .......................................................................................................................................... 35
Mirror Filtering Rules ............................................................................................................................. 35
Port Mask Filter .............................................................................................................................. 35
Packet Address Filter ..................................................................................................................... 36
Packet Divider Filter ....................................................................................................................... 36
IGMP Snooping...........................................................................................................................................
36
MLD Snooping
............................................................................................................................................ 36
IEEE 802.1X Port-Based Security..............................................................................................................
37
DoS Attack Prevention...............................................................................................................................
38
Multiple Spanning Tree Protocol
.............................................................................................................. 39
Software Reset............................................................................................................................................
39
BroadSync HD
............................................................................................................................................ 39
Time Base and Slot Generation ............................................................................................................ 39
Transmission Shaping and Scheduling ................................................................................................. 40
BroadSync HD Class5 Media Traffic.............................................................................................. 40
BroadSync HD Class4 Media Traffic.............................................................................................. 41
CableChecker..............................................................................................................................................
42
Egress PCP Remarking..............................................................................................................................
43
Address Management
................................................................................................................................ 44
Address Table Organization.................................................................................................................. 44
Address Learning .................................................................................................................................. 45
Address Resolution and Frame Forwarding.......................................................................................... 45
Unicast Addresses ......................................................................................................................... 46
Multicast Addresses ....................................................................................................................... 47
Reserved Multicast Addresses....................................................................................................... 48
Static Address Entries ........................................................................................................................... 49
Accessing the ARL Table Entries.......................................................................................................... 49
Searching the ARL Table ............................................................................................................... 49
Address Aging ....................................................................................................................................... 49
Normal Aging ................................................................................................................................. 49
Fast Aging ...................................................................................................................................... 50
Power Savings Modes................................................................................................................................
50
Auto Power Down Mode........................................................................................................................ 50
Energy Efficient Ethernet Mode............................................................................................................. 51
Deep Green Mode................................................................................................................................. 51
Interrupt.......................................................................................................................................................
52
Broadcom
®
September 12, 2016 • 53106S-DS103-R
Page 5
BROADCOM CONFIDENTIAL

BCM53106SIFBG Related Products

BCM53106SIFBG BCM53106SKFBG
Description Ethernet Transceiver, Ethernet Transceiver,
Is it Rohs certified? conform to conform to
Maker Broadcom Broadcom
package instruction FBGA-212 FBGA-212
Reach Compliance Code compliant compliant
JESD-30 code S-PBGA-B212 S-PBGA-B212
length 11 mm 11 mm
Humidity sensitivity level 3 3
Number of functions 1 1
Number of terminals 212 212
Maximum operating temperature 85 °C 70 °C
Package body material PLASTIC/EPOXY PLASTIC/EPOXY
encapsulated code TFBGA TFBGA
Package shape SQUARE SQUARE
Package form GRID ARRAY, THIN PROFILE, FINE PITCH GRID ARRAY, THIN PROFILE, FINE PITCH
Peak Reflow Temperature (Celsius) NOT SPECIFIED NOT SPECIFIED
Maximum seat height 1.017 mm 1.017 mm
Nominal supply voltage 1 V 1 V
surface mount YES YES
technology CMOS CMOS
Telecom integrated circuit types ETHERNET TRANSCEIVER ETHERNET TRANSCEIVER
Temperature level INDUSTRIAL COMMERCIAL
Terminal form BALL BALL
Terminal pitch 0.65 mm 0.65 mm
Terminal location BOTTOM BOTTOM
Maximum time at peak reflow temperature NOT SPECIFIED NOT SPECIFIED
width 11 mm 11 mm
Application of tlc5510
[i=s]This post was last edited by paulhyde on 2014-9-15 03:00[/i]High speed AD - application of tlc5510, the sampling rate is 20M. Contains circuit diagrams for classic applications....
fzu18303biao Electronics Design Contest
The main differences between modern PLC and PAC
[font=Arial]In order to clarify the difference between modern PLC and PAC (see Table 2), it is necessary to have a clear understanding of the definition of PAC. In 2004, C. Resnick of the ARC Consulti...
jek9528 Industrial Control Electronics
485 Circuit Set (.sch + program)
Various 485 circuit sets...
tonytong MCU
Automatically load USB devices at startup
After WinCE is started, if you insert a USB flash drive or USB network card, the system can detect the insertion of the new device and load it automatically. However, if you restart the computer at th...
sucola Embedded System
Share and win development board: Tell your friends that ST national tour seminar is in progress
[font=微软雅黑][size=4][color=#ff0000][b]***[/b][/color]ST official announcement: Due to the typhoon, the STM32 Shenzhen seminar originally scheduled for [color=#ff0000][b]Monday (September 17) will be re...
EEWORLD社区 stm32/stm8
Remembering a great man of analog technology
Bob Pease (August 22, 1940 - June 18, 2011) was a man who devoted his life to analog circuit design. His passing is a great loss to the analog technology community. He was knowledgeable and experience...
德州仪器 Analogue and Mixed Signal

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1345  141  1496  882  2847  28  3  31  18  58 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号