PME285
• EMI suppressor, class X2, metallized paper
• 0.001 – 0.1 µF, 275 VAC, +110 °C
• The highest possible safety regarding
active and passive flammability.
• Self-extinguishing encapsulation. The
material is recognized according to
UL 94 V-0.
• Very precise positioning of leads in
relation to the case giving efficient
utilisation of PC board space.
• Excellent self-healing properties.
Ensures long life even when subjected to
frequent overvoltages.
• High dU/dt capability.
• Good resistance to ionisation due to
impregnated dielectric.
• The capacitors meet the most stringent
IEC humidity class, 56 days.
• The impregnated paper ensures
excellent stability giving outstanding
reliability properties, especially in
applications having continuous
operation.
L
TYPICAL APPLICATIONS
CONSTRUCTION
Multi-layer metallized paper. Encapsulated
The capacitors are intended for use as
interference suppressors in X2, across-the- and impregnated in self-extinguishing
material meeting the requirements of UL
line, antenna-coupling and line-by-pass.
94V-0.
B
0.5
H
p
±
0.3
l
∅
0.8
TECHNICAL DATA
Rated voltage
Capacitance range
Capacitance tolerance
Temperature range
Climatic category IEC
Approvals
Dissipation factor tanδ
Insulation resistance
Resonance frequency
In DC applications
275 VAC 50/60 Hz
0.001 – 0.1 µF
± 20%
–40 to +110°C
40/110/56/B
S, N, D, FI, VDE, SEV, IMQ, UL, CSA
≤
1.3 % at 1 kHz
o
N
or
f
t
≥
12000 MΩ
Measured at 500 VDC after 60 s, +23°C
Tabulated self-resonance frequencies f
0
refer to 5 mm
lead lengths.
Recommended voltage:
≤
630 VDC
ew
n
de
gn
si
l = standard : 30 +5/-0 mm
option : short leads, tolerance +0/-1 mm
(standard 6 mm, code R06)
Other lead lengths on request
Test voltage between
terminals
The 100% screening factory test is carried out at
2150 VDC. The voltage level is selected to meet the
requirements in applicable equipment standards.
ENVIRONMENTAL TEST DATA
Vibration
Bump
Solderability
Active flammability
Passive flammability
Humidity
IEC 60068-2-6, Test Fc
3 directions at 2 hour each
10 – 500 Hz at 0.75 mm or 98 m/s
2
No visible damage
No open or short circuit
No visible damage
No open or short circuit
Wetting time < 1 s
IEC 60068-2-29, Test Eb 4000 bumps at 390 m/s
2
IEC 60068-2-20, Test Ta Solder globule method
EN 132400
IEC 60384-14(1993)
EN 132400
IEC 60068-2-3, Test Ca
+40°C and 90 – 95% R.H.
56 days
75