Description
Aluminum Electrolytic Capacitor, Polarized, Aluminum (wet), 50V, 20% +Tol, 20% -Tol, 4.7uF, Through Hole Mount, ROHS COMPLIANT
CategoryPassive components    capacitor   
File Size58KB,2 Pages
ManufacturerYAGEO
Websitehttp://www.yageo.com/
Environmental Compliance  
Download Datasheet Parametric View All

SS050M4R70B7S70407 Overview

Aluminum Electrolytic Capacitor, Polarized, Aluminum (wet), 50V, 20% +Tol, 20% -Tol, 4.7uF, Through Hole Mount, ROHS COMPLIANT

SS050M4R70B7S70407 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerYAGEO
package instruction,
Reach Compliance Codecompliant
ECCN codeEAR99
capacitance4.7 µF
Capacitor typeALUMINUM ELECTROLYTIC CAPACITOR
dielectric materialsALUMINUM (WET)
leakage current0.003 mA
Manufacturer's serial numberSS
Installation featuresTHROUGH HOLE MOUNT
negative tolerance20%
Number of terminals2
Maximum operating temperature105 °C
Minimum operating temperature-40 °C
Package shapeCYLINDRICAL PACKAGE
method of packingBULK
polarityPOLARIZED
positive tolerance20%
Rated (DC) voltage (URdc)50 V
ripple current29 mA
surface mountNO
Delta tangent0.1
Terminal shapeWIRE
YAGEO CORPORATION
ALUMINUM ELECTROLYTIC CAPACITORS
Miniature Size Aluminum
Electrolytic Capacitors
SS
[ For Super Miniature ]
ELECTRICAL CHARACTERISTICS
Operating Temperature : -40° ~ +105°C
Working Voltage : 6.3 ~ 80V
Rate Capacitance Range : 0.1 ~ 470µF
Capacitance Tolerance : -20 ~ +20%
DC Leakage Current (µA) : I = 0.01CV (µA) or 3µA Whichever is greater.
DESCRIPTION
This type is designed to meet the demand or
equipments for greatly reduced size and thickness,
such as: portable micro computer, disk driver, small
calculator and audio equipement.
( After 2 Minutes Application of DC Working Voltage at 25°C )
Dissipation Factor : at 120 Hz, 25°C
W V (V) : 6.3
D.F (%) : 24
10
20
16
17
25
15
35
12
50
10
63
8
80
8
Load Life : 1000 Hours at 105°C Assured with Full Rated Maximum Ripple Current Applied
Application :
Portable Micro Computer,
Disk Driver,
Small Calculator and Audio
(a) Capacitance Change : Within 20% of Initial Value
(b) Dissipation Factor : Not Exceed 200% of Initial Requirement
(c) Leakage Current : Not Exceed the Initial Requirement
Shelf Life : 500 Hours, No Voltage Applied, at 105°C
Multiplier for Ripple Current
Frequency (Hz)
0.1~47µF
100~330µF
50
0.75
0.75
120
1.00
1.00
300
1.20
1.10
1K
1.30
1.15
10K
1.50
1.20
(a) Capacitance Change : Within 20% of Initial Value
(b) Dissipation Factor : Not Exceed 200% of Initial Requirement
(c) Leakage Current : Not Exceed 200% of Initial Requirement
Temperature(°C)
Factor
65
1.70
85
1.30
105
1.00
Dimensions : mm
Rubber Stand-off
DIAGRAM OF DIMENSIONS
Vinyl Sleeve
(P.V.C)
Rubber End Seal
Vinyl Sleeve
(P.V.C)
Rubber End Seal
F 0.5
F
1.5
2.0
2.5
3.5
0.45
F 0.5
0.4Max.
15Min.
4.0
5.0
L
15Min.
5Min.
D 0.5
L
5Min.
D 0.5
6.3
8.0
0.5
CCS6 beta version available for download
[size=4][url=http://software-dl.ti.com/dsps/forms/self_cert_export.html?prod_no=ccs_setup_ib_6.0.0.00054.exe&ref_url=http://software-dl.ti.com/dsps/dsps_public_sw/sdo_ccstudio/CCSv6/CCS_6_0_0/]Downloa...
wstt Microcontroller MCU
[RVB2601 creative application development] Mobile modbus master station
Project Name : Mobile Modbus Master Station Author : shileiwu05051. Project BackgroundI have been engaged in the agricultural sensor industry for more than a year. At present, most of the transmission...
shileiwu0505 XuanTie RISC-V Activity Zone
Survey on FPGA and CPLD working experience?
Dear forum friends: How many years have you been involved in the FPAG and CPLD application industry? Do you have any experience to share with us?...
eeleader FPGA/CPLD
I would like to ask how to use a USB disk as a boot disk in Vxworks operating system?
I want to learn how to use a USB disk as a boot disk recently!! I would like to ask for the specific steps to use a USB disk as a boot disk in the Vxworks operating system?? Could you give me some adv...
renrongwen Real-time operating system RTOS
Does TI zigbee generally use OAD or OTA for over-the-air firmware upgrade?
Does TI zigbee generally use OAD or OTA for over-the-air firmware upgrade?...
ljt8015 RF/Wirelessly
Bank receipt software development
The machine is similar to an ATM. It is just pure hardware. There is no operating system on it. The functions to be realized are: there is a card reader or password input, identify the user identity, ...
54288519 Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2561  1374  1444  2856  705  52  28  30  58  15 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号