Strip Terminal Block, 6.5A, 1 Row(s), 1 Deck(s)
CategoryThe connector    terminals   
File Size65KB,1 Pages
ManufacturerWieland Electric GmbH
Websitehttps://www.wieland-electric.com/
Environmental Compliance
Download Datasheet Parametric View All

25.303.0953.0 Overview

Strip Terminal Block, 6.5A, 1 Row(s), 1 Deck(s)

25.303.0953.0 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
Reach Compliance Codecompli
ECCN codeEAR99
Other featuresPOLYAMIDE, 94V-0
Fastening methodPLUG IN
Manufacturer's serial number8213S
Installation typePANEL
Number of layers1
Rows1
Number of channels9
Rated current6.5 A
Rated voltage300 V
safety certificateUL; CSA
Terminal and terminal strip typesSTRIP TERMINAL BLOCK
Wire gauge12 AWG
Base Number Matches1
wiecon
Insulated header for panel mount feed through,
Spacing: 5.08 mm
Wire wrap connection 1 x 1
Max. pin diameter: 0.8 mm
Rated current: 6.5 A
Solder eyelets
Rated cross section:
1.5 mm
2
solid/
1.0 mm
2
fine stranded
Rated current: 12 A
Quick connect tabs
2.8 x 0.8 DIN 46249
Rated cross section:
1.0 mm
2
fine stranded
Rated current: 8 A
250 V/4 kV/3 – Overvoltage category III
400 V/4 kV/2 – Overvoltage category II
1000 V/4 kV/1 – Overvoltage category I
wire wrap
codable
with solder eyelets / quick connect tabs
Type 8213 S/... DFWW,
8213 S/... DFWW M
Rated voltages: VDE 0110
UL ratings
CSA ratings
Approvals
Std. pack
G
T
Poles
Type 8213 S/... DFLS,
8213 S/... DFLS M
6.5 A
6.5 A
No. 22 – 12 AWG
No. 22 – 12 AWG
Part no.
No. 22 – 12 AWG
No. 22 – 12 AWG
Part no.
300 V
300 V
Part no.
300 V
300 V
Part no.
12/8 A
8A
iqwd
iqwd
Spacing: 5.08 mm
100
100
50
50
50
50
50
50
50
50
50
50
50
50
50
30.48
35.56
40.64
45.72
50.80
55.88
60.96
66.04
71.12
76.20
81.28
86.36
91.44
96.52
101.60
5.08
10.16
15.24
20.32
25.40
30.48
35.56
40.64
45.72
50.80
55.88
60.96
66.04
71.12
76.20
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
unmarked
25.303.0253.0
25.303.0353.0
25.303.0453.0
25.303.0553.0
25.303.0653.0
25.303.0753.0
25.303.0853.0
25.303.0953.0
25.303.1053.0
25.303.1153.0
25.303.1253.0
25.303.1353.0
25.303.1453.0
25.303.1553.0
25.303.1653.0
without screw flange
unmarked
25.313.0253.0
25.313.0353.0
25.313.0453.0
25.313.0553.0
25.313.0653.0
25.313.0753.0
25.313.0853.0
25.313.0953.0
25.313.1053.0
25.313.1153.0
25.313.1253.0
25.313.1353.0
25.313.1453.0
25.313.1553.0
25.313.1653.0
with screw flange
unmarked
25.303.3253.0
25.303.3353.0
25.303.3453.0
25.303.3553.0
25.303.3653.0
25.303.3753.0
25.303.3853.0
25.303.3953.0
25.303.4053.0
25.303.4153.0
25.303.4253.0
25.303.4353.0
25.303.4453.0
25.303.4553.0
25.303.4653.0
without screw flange
unmarked
25.313.3253.0
25.313.3353.0
25.313.3453.0
25.313.3553.0
25.313.3653.0
25.313.3753.0
25.313.3853.0
25.313.3953.0
25.313.4053.0
25.313.4153.0
25.313.4253.0
25.313.4353.0
25.313.4453.0
25.313.4553.0
25.313.4653.0
with screw flange
17 to 22pole upon request
Mounting dimensions
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17 to 24pole upon request
13.18
18.26
23.34
28.42
33.50
38.58
43.66
48.74
53.82
58.90
68.98
69.06
74.14
79.22
84.30
20.32
25.40
30.48
35.56
40.64
45.72
50.80
55.08
60.96
66.04
71.12
76.20
81.28
86.36
91.44
a
b
Accessories:
Coding piece (strip)
Set of screws
100
100
05.561.0053.0
Z6.012.0812.0
05.561.0053.0
Z6.012.0812.0
305
wiecon
DMA serial port output
I redirected the redirection function to the DMA send buffer. Now I want to read the data in the send buffer. How can I read it out? Can I display it on the serial port after reading it out?...
注孤终 GD32 MCU
Live broadcast with prizes: Renesas Electronics Secure IoT Suite provides you with secure cloud connection solutions
Event details >> [url=https://www.eeworld.com.cn/huodong/Renesas_20181030/][b][font=Segoe UI][size=4][color=#ff0000]Reward live broadcast: Renesas Electronics Secure IoT Suite provides you with secure...
千里千寻722 Integrated technical exchanges
uC/OS-II 51 MCU transplantation, assembly part link error
I want to port a uC/OS-II to a 51 (C8051F040) microcontroller. The C language part is compiled and linked successfully, but the assembly part related to the MCU is compiled successfully but cannot be ...
vvsanny Embedded System
It would be nice if there is a high-speed train from Beijing to Jiangxi.
I went back home recently, and I didn't expect to have to go through so much trouble again. It was really stressful to sit for more than 10 or 20 hours. It would be great if a high-speed train from Be...
wateras1 Talking
Porting modbus/tcp on lm3s9b90
Same topic, want to port modbus protocol on 9B90.I found the freemodbus program and I can roughly understand the underlying definition, but the official website says that it can be used with the TCPIP...
collean Microcontroller MCU
[Help] W5300 UDP cannot receive data
dsp controls W5300 to use UDP to send and receive data with PC. W5300 has no problem with UDP sending, but cannot receive UDP packets from PC. The code is as follows. When debugging in CCS4.2, rxlen (...
warcraftiii Embedded System

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 600  1715  952  2606  2356  13  35  20  53  48 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号