EEWORLDEEWORLDEEWORLD

Part Number

Search

Z20680R600DB

Description
Fixed Resistor, Metal Foil, 2W, 80.6ohm, 500V, 0.5% +/-Tol, -.2,.2ppm/Cel
CategoryPassive components    The resistor   
File Size491KB,6 Pages
ManufacturerVishay
Websitehttp://www.vishay.com
Download Datasheet Parametric View All

Z20680R600DB Overview

Fixed Resistor, Metal Foil, 2W, 80.6ohm, 500V, 0.5% +/-Tol, -.2,.2ppm/Cel

Z20680R600DB Parametric

Parameter NameAttribute value
Is it lead-free?Contains lead
Is it Rohs certified?incompatible
MakerVishay
Reach Compliance Codecompliant
ECCN codeEAR99
structureRectangular
JESD-609 codee0
Lead diameter0.64 mm
Lead length25.4 mm
lead spacing22.86 mm
Manufacturer's serial numberZ206
Number of terminals2
Maximum operating temperature175 °C
Minimum operating temperature-55 °C
Package height10.49 mm
Package length30.48 mm
Package shapeRECTANGULAR PACKAGE
Package formRadial
Package width6.6 mm
method of packingBulk
Rated power dissipation(P)2 W
resistance80.6 Ω
Resistor typeFIXED RESISTOR
seriesZ206
technologyMETAL FOIL
Temperature Coefficient-.2,.2 ppm/°C
Terminal surfaceTin/Lead (Sn/Pb)
Tolerance0.5%
Operating Voltage500 V
Z Series (Z-Foil)
Vishay Foil Resistors
Ultra High Precision Z-Foil Resistor with TCR of ± 0.05 ppm/°C,
Tolerance of ± 0.005 % (50 ppm), Load Life Stability of ± 0.005 %,
ESD Immunity up to 25 kV and Thermal EMF of 0.05 µV/°C
FEATURES
NEW
INTRODUCTION
The Bulk Metal
®
Foil resistor is based on a special concept
where a proprietary bulk metal cold rolled foil is cemented to
a ceramic substrate. It is then photoetched into a resistive
pattern. Furthermore, it is laser adjusted to any desired value
and tolerance. Because the metals used are not drawn,
wound or mistreated in any way during manufacturing
process, the Bulk Metal Foil resistor maintains all its design,
physical and electrical characteristics while winding of wire
or sputtering does not. Z foil resistors achieve maximum
stability and near-zero TCR. These performance
characteristics are built-in for every unit, and do not rely on
screening or other artificial means for uniform performances.
The stability of a resistor depends primarily on its history of
exposures to temperature. Stability is affected by:
1. Changes in the ambient temperature and heat from
adjacent components (defined by the Temperature
Coefficient of Resistance, or TCR)
2. Destabilizing thermal shock of suddenly-applied power
(defined by the power coefficient, or PCR)
3. Long-term exposure to applied power (load-life stability)
4. Repetitive stresses from being switched on and off
In very high-precision resistors, these effects must be taken
into account to achieve high stability with changes in load
(Joule Effect) and ambient temperature.
Vishay’s new Z-Foil technology provides an order of
magnitude reduction in the Bulk Metal Foil element’s
sensitivity to temperature changes - both external and
internal. This technology provides an absolute TCR of
± 0.05 ppm/°C typical (instrument range: 0 °C to +60 °C),
± 0.2 ppm/°C typical (military range: - 55 °C to + 125 °C,
+ 25 °C ref), and a PCR of 5 ppm at rated power.
In order to take full advantage of this TCR improvement, it is
necessary to take into account the differences in the
resistor’s response to each of the above-mentioned effects.
The Z series has been developed to successfully deal with
these factors.
Temperature coefficient of resistance (TCR):
- ± 0.05 ppm/°C typical (0 °C to + 60 °C)
- ± 0.2 ppm/°C typical (- 55 °C to + 125 °C,
+ 25 °C ref.) (see table 1)
Rated power: to 1 W at + 125 °C
Resistance tolerance: to ± 0.005 % (50 ppm)
Load life stability: to ± 0.005 % at 70 °C, 2000 h or to
±0.015% at 70°C,10000 h (see table 4)
Resistance range: 10
Ω
to 600 kΩ
Vishay Foil Resistors are not restricted to standard values;
specific “as required” values can be supplied at no extra
cost or delivery (e.g. 1K2345 vs. 1K)
Total accumulated change in resistance over life (EOL)
< 0.05 % (or better with PMO)
Electrostatic discharge up to 25 000 V
Non-inductive, non-capacitive design
Rise time: 1 ns effectively no ringing
Current noise: 0.010 µV
RMS
/V of applied voltage (< - 40 dB)
Thermal EMF: 0.05 µV/°C typical
Voltage coefficient: < 0.1 ppm/V
Low inductance: < 0.08 µH typical
Thermal stabilization time < 1 s (nominal value achieved
within 10 ppm of steady state value)
Pattern design minimizing hot spots
Terminal finish: lead (Pb)-free or tin/lead alloy
Matched sets are available per request
(TCR tracking: to 0.5 ppm/°C)
Prototype quantities available in just 5 working days
or sooner. For more information, please contact
foil@vishaypg.com
Load life
ΔR
maximum can be reduced significantly
with our post manufacturing operations (PMO) see
page 4 for details
FIGURE 1 - TYPICAL RESISTANCE/
TEMPERATURE CURVE (Z-FOIL)
+ 500
+ 400
+ 300
+ 200
+ 100
ΔR
0
R
(ppm)
- 100
- 200
- 300
- 400
- 500
- 55
- 25
+ 25
+ 60 + 75 + 100 + 125
0
Ambient Temperature (°C) and TCR Chord Slopes
for Different Temperature Ranges
- 0.16 ppm/°C
TABLE 1 - TYPICAL TCR AND MAX. SPREAD
(- 55 °C to + 125 °C, + 25 °C ref.)
VALUE
100
Ω
to 600 KΩ
80
Ω
to < 100
Ω
50
Ω
to < 80
Ω
25
Ω
to < 50
Ω
10
Ω
to < 25
Ω
STANDARD
TOLERANCE
± 0.005 %
± 0.005 %
± 0.01 %
± 0.01 %
± 0.02 %
TYPICAL TCR AND
MAX. SPREAD
(ppm/°C)
± 0.2 ± 0.6
± 0.2 ± 0.8
± 0.2 ± 1.0
± 0.2 ± 1.3
± 0.2 ± 1.6
0.05 ppm/°C
- 0.1 ppm/°C
0.1 ppm/°C
0.14 ppm/°C
0.2 ppm/°C
* Pb containing terminations are not RoHS compliant, exemptions may apply
Document Number: 63187
Revision: 21-Jul-10
For any questions, contact:
foil@vishaypg.com
www.foilresistors.com
1
Come in and take a look
I want to put the hospital's intravenous drip in, and when the drip is almost finished, I have to manually call the nurse station when changing the water. I want to use the volume change of the water ...
大哥哥 51mcu
I used STM32MP1 to build an epidemic monitoring platform 3—Implementation of epidemic monitoring platform
1. Introduction Previously, I used the desktop version of Qt to implement an epidemic monitoring platform: Qt-based real-time monitoring platform for the new coronavirus epidemic data (open source sma...
ohahaha RF/Wirelessly
Letu Medical Industry 120 Ambulance Wireless Video Surveillance Solution
In modern cities, the medical rescue system is an important part of the urban security system. The 120 emergency center undertakes the task of the medical rescue command center, completes the tasks of...
dtcxn Medical Electronics
Master, I have a question for you --- TIM
In input capture mode: I now use TIM2_CH2 and TIM2_CH3 to input a PWM wave with a periodic frequency change. And both can be used in input capture mode (complete the capture of two rising edges in the...
ws840914 stm32/stm8
Let’s discuss the company’s zero-crossing detection circuit!
This is a zero-crossing detector designed by the company's engineering assistant! Please discuss!...
林发扬 Analog electronics
Throwing Away the Current Transformer - Part 3: How to Use Shunt Current Sensors in Multiphase Metering Systems
[align=left][color=#000]Shunts are often used as current sensors in metering systems because of the many advantages they offer. [/color][/align][align=left][color=#000]However, as discussed in the pre...
maylove Analogue and Mixed Signal

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 769  1388  1708  2840  1120  16  28  35  58  23 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号