EEWORLDEEWORLDEEWORLD

Part Number

Search

KWBEWACD

Description
Snap Acting/Limit Switch, SPDT, Momentary, 0.05A, 28VDC, 11.84mm, Quick Connect Terminal, Straight Type Actuator, Panel Mount
CategoryMechanical and electronic products    switch   
File Size114KB,2 Pages
ManufacturerThe Cherry Corporation
Download Datasheet Parametric View All

KWBEWACD Overview

Snap Acting/Limit Switch, SPDT, Momentary, 0.05A, 28VDC, 11.84mm, Quick Connect Terminal, Straight Type Actuator, Panel Mount

KWBEWACD Parametric

Parameter NameAttribute value
MakerThe Cherry Corporation
Reach Compliance Codeunknown
ECCN codeEAR99
Actuator stroke11.84 mm
Actuator typeSTRAIGHT TYPE
body width10.31 mm
body height15.88 mm
Body length or diameter28.96 mm
Maximum contact current (DC)0.05 A
Contact (DC) maximum rated R load.05A@28VDC
Maximum contact voltage (DC)28 V
Electrical life100000 Cycle(s)
Manufacturer's serial numberK
Installation featuresPANEL MOUNT
Maximum operating force0.18 N
Maximum operating temperature150 °C
Minimum operating temperature-40 °C
Maximum pre-travel7.22 mm
surface mountNO
Switch actionMOMENTARY
switch functionSPDT
Switch typeSNAP ACTING/LIMIT SWITCH
Termination typeQUICK CONNECT
MINIATURE
K Series
Features
Choice of current ratings up to 25 amps
Choice of actuators
Choice of terminals
3 contact arrangements
Choice of operating force
Long mechanical life
Wiping contact action
Snap over actuators
Agency approved extended life versions
Flame retardant, UL94V-O
self-extinguishing
case and cover
Long-life snap action
switch mechanism
ARC-resistant case
has internal barriers,
4mm minimum between
live parts and external
hardware
NC terminal
NO terminal
International Approved Versions
K Series switches, except 25A (KWS), are
internationally approved. Switches with
straight terminals may require insulated
connectors for international approval.
Choice of U.S. (#4 screw)
or metric (3mm screw)
Common terminal
Single or double throw, either
normally open or normally closed
Electrical Ratings
Switch
Series
EN61058 Rating
UL1054 Rating
Electrical Life at Rated Load
According to VDE
According to UL
(Min. Operations)
(Min. Operations)
KWA/KWB
KWC/KWD
KWE/KWF
KWG/KWH
KWJ/KWK
KWL
50mA, 28VDC
1(0.5)A, 250VAC
3(1)A, 250VAC
6(2)A, 250VAC
10(3)A, 250VAC
N/A
KWM
16(4)A, 250VAC
KWS
N/A
50mA, 28VDC
1.0A, 125/250VAC
3A, 1/10HP, 125/250VAC
5A, 1/4HP, 125/250VAC
10A, 1/2HP, 125/250VAC
15.1A, 1/2HP, 125/250 VAC
5A, 125VAC Lamp Load
(85°C only)
0.5A, 125VDC
(85°C only)
0.25A, 250VDC
(85°C only)
15.1A, 1/2HP, 125/250VAC
0.5A, 125VDC
(85°C and 150°C only)
0.25A, 250VDC
(85°C and 150°C only)
15.1A, 1/2HP, 125/250VAC
(200°C only)
25A, 125/250VAC
(85°C only)
1HP, 125VAC
(85°C only)
2HP, 250VAC
(85°C only)
50,000
50,000
50,000
50,000
50,000
N/A
100,000
100,000
100,000
100,000
100,000
100,000
50,000
100,000
N/A
100,000
Specifications
Electrical
Temperature Rating:
Flammability Rating:
Materials
-40° to +85°C, 150°C or 200°C
UL94V-O
Thermoplastic Polyester (85°C or 150°C)
Liquid Crystal Polymer (200°C)
Thermoplastic Acetal (85°C)
Thermoplastic Polyester (150°C)
Liquid Crystal Polymer (200°C)
Cold-Rolled Steel (Nickel-Plated)
Brass
Copper (25 amp only)
Beryllium Copper
Silver Alloy
(except KWA and KWB — Gold-Plated)
Case/Cover:
Button:
Auxiliary Actuator:
Terminals:
Moving Blade:
Contacts:
Summary header file
...
gaoxiao Microcontroller MCU
Serial Communication
How does the microcontroller msp430 send data to the host computer through the serial port?...
菜鸟12号 Microchip MCU
Please recommend a domestic DCDC, 48 to 12V 6A
I would like to ask the big guys to recommend a domestic DCDC (or DCDC controller) that can output 12V of power from an electric vehicle with a peak current of 6A. I can hang a speaker when setting up...
LearningASM Power technology
I want VS2005/2003+winCE5.0/4.2, 2440 development board, serial port communication for a fee!
I need help from an expert on VS2005/2003+winCE5.0/4.2 environment, serial communication module of 2440 development board! Cash is required! Phone: 13759970064 I am in Xi'an. If you are from other pla...
zhtwn Embedded System
Use J-LINK to debug the EK-LM3S8962 development board!
The first step after receiving the EK-LM3S8962 development board is to plug in the jlink. I didn't expect that the j-link command would prompt that there was no target board.I found the readme of the ...
fengzhang2002 Microcontroller MCU

Technical ResourceMore

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1120  306  911  2587  1145  23  7  19  53  24 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号