SPECIFICATION CONTROL DRAWING
TITLE
55A7226
Date
THREE CONDUCTOR CABLE, JACKETED, GENERAL PURPOSE, 600 VOLT
4-2-06
Revision
A
This specification sheet forms a part of the latest issue of Raychem Specification 55A.
COMPONENT WIRES - 55A0213
JACKET - RADIATION-CROSSLINKED,
MODIFIED ETFE
FILAMENT STRIPPING THREAD - NOMEX®, 200/I/4E, No finish
CONSTRUCTION DETAILS
PART NUMBER
1/
CONDUCTOR
SIZE
(AWG)
22
20
18
16
14
12
JACKET THICKNESS
(inches)
MINIMUM
.006
.006
.006
.006
.006
.007
NOMINAL
.008
.008
.008
.008
.008
.009
OUTSIDE DIAMETER
(inches)
NOMINAL
.113
.130
.152
.169
.206
.247
MAXIMUM
.119
.137
.160
.178
.216
.259
MAXIMUM
WEIGHT
(lb/1000 ft)
11.6
16.8
24.1
30.3
45.5
67.8
55A7226-22-*
55A7226-20-*
55A7226-18-*
55A7226-16-*
55A7226-14-*
55A7226-12-*
CABLE RATINGS AND ADDITIONAL REQUIREMENTS
TEMPERATURE RATING: 200°C
Maximum continuous conductor temperature
VOLTAGE RATING: 600 volts (rms)
ACCELERATED AGING: 300 ± 3°C for 7 hours
BLOCKING: 200 ± 3°C for 6 hours
DIELECTRIC WITHSTAND: 1500 volts (rms), 60 Hz
FLAMMABILITY:
Procedure 1, 3 seconds (maximum); 3 inch (maximum);
no flaming of facial tissue
JACKET COLOR: White preferred
JACKET ELONGATION AND TENSILE STRENGTH:
Elongation, 50% (minimum)
Tensile Strength, 5000 lbf/in² (minimum)
NOTE:
Nominal values are for information only.
Nominal values are not requirements
LIFE CYCLE: 230 ± 3°C for 500 hours
LOW TEMPERATURE-COLD BEND: -65 ± 3°C for 4 hours
PART NUMBER
The "*" in the part numbers above shall be replaced by
color code designators with a slash separating the
component wire colors and a dash separating the
component wire colors from the jacket color. Colors shown
do not necessarily reflect the sequence of manufacturing.
1/ Example: AWG 20, black, red and orange component wires;
white jacket: 55A7226-20-0/2/3-9
NOMEX® is a registered trademark of E.I. du Pont de Nemours and Company.
Users should evaluate the suitability of this product for their application. Specifications are subject to change without notice.
Tyco Electronics also reserves the right to make changes in materials or processing, which do not affect compliance with any specification, without notification to Buyer.
1/ COLORS AND COLOR CODE DESIGNATORS SHALL BE IN ACCORDANCE WITH MIL-STD-681. HOWEVER, DUE TO LENGTH LIMITATIONS OF THE RAYCHEM PART NUMBER,
AN ALTERNATIVE COLOR CODE MAY REPLACE MIL-STD-681 COLOR CODE DESIGNATORS. (EXAMPLE: “901/902...” MAY BE REPLACED BY “Axxx”.) OTHER CODES AND
SUFFIXES MAY BE ADDED TO THE PART NUMBER, AS NECESSARY, TO CAPTURE ANY ADDITIONAL REQUIREMENTS IMPOSED BY THE PURCHASE ORDER.
DIMENSIONS ARE IN INCHES, AND UNLESS OTHERWISE DESIGNATED ARE NOMINAL.
R
Wire & Cable
501 Oakside Avenue
Redwood City, CA 94063-3800
Phone: 1-800-227-8816
Fax: 1-650-361-6297
Page 1 of 1
THIS SPECIFICATION SHEET TAKES PRECEDENCE OVER DOCUMENTS REFERENCED HEREIN.
REFERENCED DOCUMENTS SHALL BE OF THE ISSUE IN EFFECT ON DATE OF INVITATION FOR BID.
© 2006 Tyco Electronics Corporation. All rights reserved.