9
SYSMAC Remote Master Modules
Wired and Fiber-optic Remote I/O
Systems Match Your Distance Needs
1
Wired remote I/O systems offer up to
200 m maximum distance using
shielded twisted pair wire, Belden #9271
or equivalent
C200H-RM†01
†
1
Fiber-optic remote I/O systems prevent
electrical noise from fouling long-
distance communication signals
1
Transmission distance with fiber-optic
cables depends on core material: 20 m
for all plastic; 200 m for plastic clad
1
Master modules connect to slave racks
or remote I/O relay or transistor blocks
Ordering Information
3
WIRED REMOTE I/O SYSTEM
Classification
Remote master
Transmission line
Description
For CS1, C200H, C200H Alpha systems
Shielded twisted pair cable
Specification
Use up to 2 masters per CPU
Belden #9271 or equivalent
Part number
C200H-RM201
Commercially available
3
FIBER-OPTIC REMOTE I/O SYSTEM
Classification
Remote master
Transmission media
Description
For CS1, C200H, C200H Alpha systems
APF (all plastic) fiber-optic cable
(user must assemble connectors)
Connectors, brown (includes 2)
Connectors, black (includes 2)
HPCF (
(plastic clad) fiber-optic cable,
)
,
indoor/outdoor use
i d / td
(user must assemble connectors)
Specification
Use up to 2 masters per CPU
20 m (65 ft), without connectors
For cables 0 to 10 m length
For cables 8 to 20 m length
50 m (164 ft)
100 m (328 ft)
500 m (1640 ft)
1 km (3280 ft)
Zipcord style, orange, without connectors
Connectors for SYSMAC BUS
Termination kit for HPCF cable
50 m (164 ft)
Order two, one for each end
------
Part number
C200H-RM001-PV1
B500-PF212
3G5A2-CO001
3G5A2-CO002
FCS-HCR-LB-501
FCS-HCR-LB-102
FCS-HCR-LB-502
FCS-HCR-LB-103
FCS-HCR-CO-501
S3200-COCH82
FCS-CAK6230-US
3
REMOTE SLAVE RACKS
For part numbers and configuration information, refer to the CS1 or C200H Alpha Programmable Controller Catalogs, or
C-Series Wired
Remote I/O Manual
(W120) or
C-Series Fiber-optic Remote IO Manual
(W136).
C200H-RM†01
†
C200H-RM†01
†
Specifications
3
COMMUNICATIONS SPECIFICATIONS
Communications method
Coding method
Connection method
Communications baud rate
Communications cable
Communications
distance
di t
Wired
Fiber-optic
Half-duplex
Manchester coding method
RS-485
187.5 kbps
C200H-RM201: 2-conductor cable: Belden #9271 or VCTF (JIS L3306)
C200H-RM001: Fiber-optic cable: all plastic or hard plastic clad fiber media
Belden #9271 or VCTF cable: 200 m (656 ft)
All plastic fiber (APF): 20 m (65.6 ft)
Hard plastic fiber (HPCF): 200 m (656 ft)
32 (512 words max.)
Manchester code check, frame length check, and parity check
Max. number of connecting nodes
Error control checks
3
MODULE SPECIFICATIONS
Current consumption
Number of I/O points
Number of occupied words
Omron PLC model
Max. number of Slaves per Master
Approved standards
C200H-RM201 wired master: 0.25 A
C200H-RM001 fiber-optic master: 0.2 A
512 max.
512 max.
CS1, C200HX (-ZE), C200HG (-ZE), C200HE (-ZE), C200HS
32
UL 508 (E95399), CSA C22.2 No. 142 (LR51460)
Note: For detailed specifications on wired or fiber-optic SYSMAC BUS systems, refer to the following manuals:
W120
C-Series Wired Remote I/O
W136
C-Series Fiber-optic Remote I/O
Dimensions
Unit: mm (inch)
C200H-RM001-PV1 C200H-RM201
RM201
130
(5.12)
35 (1.38)
100 (3.94)
Note: Refer to the
C200HX, C200HG, C200HE, C200HS,
or
CS1 Operation Manual
for
details on the dimensions when the Master Module is installed in the PLC Backplane.
2