EEWORLDEEWORLDEEWORLD

Part Number

Search

381LX102M100H032

Description
Aluminum Electrolytic Capacitor, Polarized, Aluminum (wet), 100V, 20% +Tol, 20% -Tol, 1000uF, Through Hole Mount, ROHS COMPLIANT
CategoryPassive components    capacitor   
File Size693KB,11 Pages
ManufacturerCDE [ CORNELL DUBILIER ELECTRONICS ]
Environmental Compliance  
Download Datasheet Parametric View All

381LX102M100H032 Online Shopping

Suppliers Part Number Price MOQ In stock  
381LX102M100H032 - - View Buy Now

381LX102M100H032 Overview

Aluminum Electrolytic Capacitor, Polarized, Aluminum (wet), 100V, 20% +Tol, 20% -Tol, 1000uF, Through Hole Mount, ROHS COMPLIANT

381LX102M100H032 Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerCDE [ CORNELL DUBILIER ELECTRONICS ]
package instruction,
Reach Compliance Codecompliant
ECCN codeEAR99
capacitance1000 µF
Capacitor typeALUMINUM ELECTROLYTIC CAPACITOR
diameter22 mm
dielectric materialsALUMINUM (WET)
ESR182 mΩ
JESD-609 codee3
leakage current0.94868 mA
length35 mm
Manufacturer's serial number381LX
Installation featuresTHROUGH HOLE MOUNT
negative tolerance20%
Number of terminals2
Maximum operating temperature105 °C
Minimum operating temperature-40 °C
Package shapeCYLINDRICAL PACKAGE
Package formSnap-in
polarityPOLARIZED
positive tolerance20%
Rated (DC) voltage (URdc)100 V
ripple current1700 mA
series381LX
surface mountNO
Terminal surfaceTin (Sn)
Terminal pitch10 mm
Terminal shapeSNAP-IN
Type 381LX / 383LX 105 °C High Ripple, Snap-In Aluminum
High Ripple, Long Life, 2, 4 and 5 pin styles available
Adding longer-life and more ripple capability to the excellent
value of Type 380L/LX capacitors, the 381L/LX readily handles
tough switching power supply input and output circuits and
motor-drive bus capacitor applications where the high surface
area of multiple units in parallel equals the ripple capability of our
Type 520C inverter-grade capacitor. Type 381LX delivers more
capacitance per can size while Type 381L gives lower ESR for the
same capacitance rating. Type 383L/LX has 4 or 5 leads for stable,
reverse-proof mounting.
Highlights
- Top performance in power supplies and motor drives
- 4 times the life of Type 380L/LX
- 2, 4 and 5 leads available
- Big selection of 42 case sizes
–40 °C to + 105 °C ≤ 250 Vdc
–25 °C to + 105 °C ≥ 315 Vdc
10 Vdc to 450 Vdc
33 µF to 150,000 µF
± 20%
≤3 √CV µA, 4 mA max, 5 minutes
Ambient Temperature
45 °C
381L
383L
381LX,
383 LX
Frequency
50 Hz
10-100 Vdc
160-450 Vdc
Low Temperature Characteristics
0.93
0.75
60 Hz
0.95
0.80
120 Hz
1.00
1.00
500 Hz
1.05
1.20
1 kHz
1.08
1.25
5 kHz
& up
1.15
1.40
2.70
2.35
60 °C
2.60
2.20
70 °C
2.50
2.00
85 °C 105°C
2.10
1.70
1.00
1.00
Specifications
Temperature Range
Rated Voltage Range
Capacitance Range
Capacitance Tolerance
Leakage Current
Ripple Current Multipliers
Impedance ratio: Z
–20⁰C
∕ Z
+25⁰C
≤ 10 (10 Vdc)
≤ 8 (16–50 Vdc)
≤ 4 (63–100 Vdc)
≤ 3 (150–450 Vdc)
3000 h at full load at 105 °C
∆ Capacitance ±20%
ESR 200% of limit
DCL 100% of limit
1000 h at 105 °C
∆ Capacitance ±20%
ESR 200% of limit
DCL 100% of limit
10 to 55 Hz, 0.06” and 10 g max, 2 h each plane
RoHS Compliant
Endurance Life Test
Shelf Life Test
Vibration
CDM Cornell Dubilier • 140 Technology Place • Liberty, SC 29657 • Phone: (864)843-2277 • Fax: (864)843-3800
Easier communication and synchronization with external instruments
As mentioned above , the2600ASeries Digital SourceMeter[1] This will provide enhanced triggering and synchronization capabilities. Usingthreein theTSP-Link, this synchronization can also be easily ext...
Jack_ma Test/Measurement
How do I choose the reference voltage for the current regulator in analog PWM control? How does it work? I beg for an answer!
How to choose the reference voltage in the middle, how does the whole current regulator work? For example, what happens when the reverse input is greater than the reference, what happens when the reve...
背成一把刀 Power technology
Interrupt Nesting
The main control chip uses PIC30F, which controls the two actuators of fuel injection and ignition, and directly uses I/O to control the on and off. The requirement is to accurately control the start ...
xishuidemian Programming Basics
How to view the interface exported by a .lib? ?
There is only one .lib, how do I know which interfaces it exports? What tool to use? I used the dependency walker that comes with vs2005 to check and got an error: Not a valid 32 or 64-bit Windows mod...
baobeidudu Embedded System
Come on, OP!
Come on, boss! If you have any information, please share it with us! Thank you very much! [email]kongxiangdongkxd@163.com[/email]...
360299294 MCU
Does anyone have the controlsuite installation package that can be sent to me?
Why can't I download controlsuite from the official website of Texas Instruments? Can anyone send me the installation package of controlsuite? QQ:1264856973...
longyun DSP and ARM Processors

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2693  674  1539  970  1631  55  14  31  20  33 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号