EEWORLDEEWORLDEEWORLD

Part Number

Search

TB800-TB-W

Description
Rocker Switch, SPDT, Latched, Solder Terminal, Rocker Actuator, Panel Mount
CategoryMechanical and electronic products    switch   
File Size111KB,1 Pages
ManufacturerCarling Technologies
Environmental Compliance  
Download Datasheet Parametric View All

TB800-TB-W Overview

Rocker Switch, SPDT, Latched, Solder Terminal, Rocker Actuator, Panel Mount

TB800-TB-W Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerCarling Technologies
Reach Compliance Codecompliant
ECCN codeEAR99
Actuator typeROCKER
body width13.81 mm
body height21.84 mm
Body length or diameter28.44 mm
Contact (AC) maximum rated R load15A@125VAC
Maximum contact current (AC)15 A
Maximum contact voltage (AC)125 V
Electrical life100000 Cycle(s)
Manufacturer's serial numberT
Installation featuresPANEL MOUNT
Maximum operating temperature85 °C
Minimum operating temperature
surface mountNO
Switch actionLATCHED
switch functionSPDT
Switch typeROCKER SWITCH
Termination typeSOLDER
Carling
Technologies
T-Series Single Pole Rocker & Paddle Switches
T-Series Single Pole Rocker & Paddle Switches
Dielectric Strength
UL/CSA:
The predecessor to the Curvette series whose versatility
1000V - live to dead metal parts
has allowed it to stand the test of time. Traditional styling
VDE:
coupled with self cleaning contacts, integrated wire leads,
4000V - live to dead metal parts;
750V - across open contacts
a multitude of circuits, ratings, and actuator choices has
Electrical Life
made the TA/LTA-Series appeal to a wide range of mar-
100,000 cycles
kets, including Appliance, HVAC, Food service,
Mechanical Life
Transportation.
100,000 cycles
Operating Temperature
32°F to 185°F (0°C to 85°C)
.156[3.96]
DIA
.220[5.59]
.069[1.75]
DIA
.375[9.52]
.055[1.40]
DIA
6.000[152.40]
.250[6.35]
.050[1.27]
.390[9.77]
.250[6.35]
.250[6.35]
.187[4.74]
SOLDER
LUG
.500[12.70]
INTEGRATED WIRE LEAD
(no exposed conductors)
.250 TAB (Q.C.)
.860[21.84]
.187 TAB (Q.C.)
TERMINAL TYPE
.550[13.97]
.375[9.52]
.544[13.81]
1.120[28.44]
.275[6.98]
SHORT PADDLE
.250[6.35]
1.125[28.57]
1.156[29.36]
.500[12.70]
.047[1.19]
.453[11.50]
.520[13.20]
MOUNTING HOLE
Panel Thickness:
.020[.508] min. to
.250[6.35] max.
.430[10.92]
MOMENTARY
ROCKER
OPERATING
POINT
PADDLE
PLUNGER
TA201
-
T B
-
B
1
Base Part Number
2
Actuator
Style
3
Actuator
Color
4
Bezel
Color/Style
1 BASE PART NUMBER: SERIES/CIRCUITRY/RATING
4
/TERMINATION
Solder Lugs
.250 Tabs
Wire Leads
10A 250 VAC, 15A 125 VAC, 3/4 HP 125-250 VAC
ON-NONE-OFF
TA200
TA201
TA205
ON-NONE-ON
TB200
TB201
TB205
ON-OFF-ON
TC200
TC201
TC205
10A 250 VAC, 15A 125 VAC, 3/4 HP 125-250 VAC, 10(4) A 250VAC T85u
6
ON-NONE-OFF
TA800
TA801
TA805
ON-NONE-ON
TB800
TB801
TB805
ON-OFF-ON
TC800
TC801
TC805
5A 250 VAC, 10A 125 VAC, 1/2 HP 125-250 VAC
(ON)-NONE-OFF
TA10A
TA10B
TA10F
ON-NONE-(OFF)
TA10L
TA10M
TA10T
ON-NONE-(ON)
TB10A
TB10B
TB10F
T-SERIES W/ PLUNGER ACTUATOR
1,2
10A 250 VAC, 16A 125 VAC, 1/2 HP 125-250 VAC
OFF-NONE-(ON)
-
TA25B-PLB-B TA25F-PLB-B
ON-NONE-(OFF)
-
-
TA25T-PLB-B
T SERIES W/ MOMENTARY ROCKER ACTUATOR
10A 250 VAC, 15A 125 VAC, 20A 125-250 VAC “H”, 3/4 HP 125-250 VAC
(ON)-NONE-OFF
-
TA22B-TLB-B
-
ON-NONE-(OFF)
-
TA22M-TLB-B
-
2 ACTUATOR STYLE
T
rocker
P
paddle
3 ACTUATOR COLOR
5
B
black
4 BEZEL COLOR
5
B
black
PS
short paddle
W
white
W
white
NOTES
Imprinting is available. Consult factory.
1
Optional plunger support option is available for applications requiring extensive lateral travel, consult factory for details.
2
Maintained circuit not available with TA22 and TA25 Series.
3
.187 tab terminals also available. Consult factory for catalog number callout.
4
Additional ratings are available. Consult factory.
5
Additional colors are available. Consult factory.
6
UL, CSA & VDE Approved.
()
Indicates momentary function.
12
www.carlingtech.com
How many kilometers does it take to change tires? [I recently rented a car and wanted to know more]
Car fans all want to get a bigger wheel hub for their car. Don’t ask why? There’s nothing wrong with being willful! But when it comes to fixing the tires, do you still dare not understand what the par...
btty038 Talking
Which development boards provide BSP that can support KITL debugging?
I have borrowed a yc2440 and sky2440, their BSPs do not support kitl debugging, and the friendly arm micro2440, it seems that it does not support kitl debugging? Now I found a Liyutai 2440 5.0 BSP SMD...
yaschiro Embedded System
LMR24220RB Power Module Review Sharing
1. Unboxing pictures. I received this gift several days ago, but I have not had time to evaluate it. I took it out for evaluation on the Labor Day holiday. The FPGA board I used was a blank board sent...
wanglong137136 Power technology
Can ARM's I2C communicate directly with MCU's I2C?
Now I want to connect the two I2C lines of 2410 directly to the I2C of a 16-bit MCU, with ARM as the master and MCU as the slave. Can communication be achieved in this way? If so, how do I get the add...
PP2008 ARM Technology
LPC1500 experience + soft interrupt
[b]Design background:[/b] 1. Select LPC1518, compile environment keil5, jlink 2. Functional application: the software framework adopts time slice scheduling management[b]A. Design sharing[/b] The soft...
xiaotianwang78 NXP MCU
TMS320C6748 development board EDMA routine
EDMA routine (1) Manually trigger event 11 to run the passed parameters in PaRAM11 and link to PaRAM10 through PaRAM.LINK. Then manually trigger event 11 to run the passed parameters in PaRAM10. exter...
灞波儿奔 Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 1133  2596  1939  98  2826  23  53  40  2  57 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号