Power/Mains Transformer, POWER TRANSFORMER, 4.5 VA
CategoryPower management    transformer   
File Size216KB,7 Pages
ManufacturerVishay
Websitehttp://www.vishay.com
Download Datasheet Parametric View All

PL-4304 Overview

Power/Mains Transformer, POWER TRANSFORMER, 4.5 VA

PL-4304 Parametric

Parameter NameAttribute value
MakerVishay
Reach Compliance Codeunknown
ECCN codeEAR99
Other featuresPCB MOUNTABLE
CertificationUL
Center click function 1NO
Center click function 2NO
high35.05 mm
Insulation voltage2500 V
length42.67 mm
Installation featuresTHROUGH HOLE MOUNTED
Number of secondary windings1
Maximum operating temperature130 °C
Output current 10.6 A
Output current 20.6 A
Output voltage 17.5 V
Output voltage 27.5 V
physical sizeL42.67XB33.02XH35.05 (mm)
main ratingDUAL 115/230V
surface mountNO
Transformer typePOWER TRANSFORMER
VA rating4.5 VA
width33.02 mm
PL-22, -23, -24, -42, -43, -44
Vishay Dale
Low Power Transformers
Dual Primary - Dual secondary
115/230 Volts
FEATURES
PL-22, PL-23, PL-24
PC pin mounting.
Provides isolation from power line.
Dual Primary for operation at 115V or 230V, 50/60Hz.
Dual Secondary for
series connection
obtains twice winding voltage with
center tap or for
parallel connection
obtains twice winding current rating.
Modification to these standard items are available as specialty products.
Laminated construction for low-cost industrial applications, including power
supplies, controls and instrumentation.
Mounting brackets and bobbin standoff are available.
PL-22, PL-23, PL-24:
Concentric windings for increased coupling, decreased
leakage reactance and improved regulation.
PL-42, PL-43, PL-44
PL-42, PL-43, PL-44:
Split-section winding for increased dielectric strength
between primary and secondary windings plus reduced interwinding
capacitance.
ELECTRICAL SPECIFICATIONS
Input Voltage:
115V 60Hz or 230V 50-60Hz.
Output Power Rating:
PL-22, PL-42 = 1.5VA.
PL-23, PL-43 = 4.5VA.
PL-24, PL-44 = 10.0VA.
Dielectric Strength:
Between primary windings and
secondary windings and core:
PL-22, PL-23, PL-24 = 1500V.
PL-42, PL-43, PL-44 = 2500V.
Between secondary windings to core: All units = 1000V.
From primary to primary windings: All units = 500V.
From secondary to secondary windings: All units = 500V.
SCHEMATICS
Basic Style
1
2
3
4
5
6
7
8
Options
1
230V
Input
2
3
4
Primary Series
Connected
5
6
7
8
1
2
3
4
Secondary
Series Connected
6
7
5
Volts
Output
MECHANICAL SPECIFICATIONS
Temperature Class:
PL-22, PL-23, PL-24: Insulation Class A, 105°C.
PL-42, PL-43, PL-44: Insulation Class B, 130°C;
A UL approved Class B Insulation System can be
furnished on request.
Terminals:
Brass, solder coated.
Weight:
(reference)
PL-22, PL-42 = 100 grams.
PL-23, PL-43 = 160 grams.
PL-24, PL-44 = 240 grams.
Document Number 34072
Revision 11-Dec-02
1
8
5
2
6
7
8
Primary
Parallel Connected
1
2
3
4
Secondary
Parallel Connected
6
5
115V
Input
4
7
Volts
Output
8
3
For technical questions, contact: Magnetics@vishay.com
www.vishay.com
155
Once on July 19 at rich Chuan the opening ceremony
Olympic Games quarter recruits to sit up a clan home pack one to become fashion!(Diagram) The quarter of Olympic Games sits up a person who see the game to want to necessarily be not in the minority, ...
herve713 Linux and Android
C64x+ Memory Organization
TI has improved the high-performance C64x core, greatly improving its performance, and called it the C64x+DSP core. All components of the DSP chip developed based on the C64x+ core are connected with ...
Aguilera DSP and ARM Processors
Is it possible to debug the Boot program in the same way as debugging loadable vxWorks?
Problem description: Hello everyone. I have an MPC85X development board with a ready-made Boot program. But I think it is not good enough, so I hope to modify the original Boot program source code and...
heanjun211 Real-time operating system RTOS
Low voltage MOS tube body diode reverse breakdown voltage
Low voltage MOS tube body diode reverse breakdown voltage...
QWE4562009 Integrated technical exchanges
09.26【Weekly Discussion】Seven days of National Day, are you ready?
The autumn weather is high and crisp, and the fruits are fragrant. In this cool season filled with the joy of harvest, we are about to usher in the 62nd birthday of our motherland. Life is so beautifu...
longxtianya Talking
Urgent, there's a problem again
I have a question. When looking at the timer A part, is it software or hardware simulation? In the up-counting mode, the interrupt occurs before the tar value reaches the set value of ccr0. What's goi...
passion07 Microcontroller MCU

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2543  1717  1085  1131  2534  52  35  22  23  32 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号