EEWORLDEEWORLDEEWORLD

Part Number

Search

LCS051T13QC26AC

Description
SNAP ACTING/LIMIT SWITCH, SPDT, MOMENTARY, 7.9mm, PANEL MOUNT, ROHS COMPLIANT
CategoryMechanical and electronic products    switch   
File Size229KB,4 Pages
ManufacturerC&K
Environmental Compliance  
Download Datasheet Parametric View All

LCS051T13QC26AC Overview

SNAP ACTING/LIMIT SWITCH, SPDT, MOMENTARY, 7.9mm, PANEL MOUNT, ROHS COMPLIANT

LCS051T13QC26AC Parametric

Parameter NameAttribute value
Is it lead-free?Lead free
Is it Rohs certified?conform to
MakerC&K
package instructionROHS COMPLIANT
Reach Compliance Codecompliant
ECCN codeEAR99
Actuator stroke7.9 mm
Actuator typeLEVER
body width6.4 mm
body height9.8 mm
Body length or diameter19.8 mm
Contact (AC) maximum rated R load6A@250VAC
Maximum contact current (AC)6 A
Maximum contact voltage (AC)250 V
Electrical life10000 Cycle(s)
Manufacturer's serial numberLCS
Installation featuresPANEL MOUNT
Maximum operating force1.47 N
Maximum operating temperature125 °C
Minimum operating temperature-40 °C
Maximum pre-travel6.3 mm
sealIP67
surface mountNO
Switch actionMOMENTARY
switch functionSPDT
Switch typeSNAP ACTING/LIMIT SWITCH
Termination typeQUICK CONNECT
LCS Series
Subminiature Sealed Snap-acting Switches
Features/Benefits
Compact design
Long life and high electrical capacity
Quick connect, solder terminals,
PC terminals, wire leads
Wide variety of actuator styles
RoHS compatible, RoHS compliant
IP67
Specifications
CONTACT RATING: 6 AMP, 125/250 V AC
and
5 AMP, 125/250 V AC
0.1 AMP, 125/250 V AC
ELECTRICAL LIFE: 10,000 cycles
INSULATION RESISTANCE: 100 M ohm min.
DIELECTRIC STRENGTH: 1,000 VAC
OPERATING TEMPERATURE: –40ºC to +125ºC without wire
–40ºC to +85ºC with wires
OPERATING FORCE: (see ACTUATOR’S option sections).
MOUNTING: 2-56 screws, torque 2.3 in/lbs max.
NOTE:
Specifications and materials listed above are for switches with standard options.
For information on specific and custom switches, consult Customer Service center.
14
Typical Applications
Motorized equipment
Sump pump
Thermostatic controls
Computers
Air conditioners
14
Models Available
Materials
SWITCH HOUSING: Thermoplastic polyester or high temperature
thermoplastic (PTS) (UL 94V-0).
ACTUATOR BUTTON: Thermoplastic polyester.
SPRING: Copper alloy.
PIVOT: Copper alloy.
MOVABLE CONTACTS: Silver nickel
STATIONARY CONTACTS: Silver nickel on copper alloy.
TERMINALS: Copper alloy.
ACTUATOR LEVEL: Stainless steel.
J
Snap-acting
Build-A-Switch
To order, simply select desired option from each category and place in the appropriate box. Available options are shown and
described on pages J-27 thru J-29. For additional options not shown in catalog, consult Customer Service Center.
L
Series
LCS
Contact Rating
05
5 AMP, 125/250 V AC
6 AMP, 125/250 V AC
01
0.1 AMP, 125/250 V AC
C
S
14
Operating Force
1
150 grams
2
203 grams
Actuator
P00
Pin plunger
T00
0.45 mm short lever
T05
5.05 mm short lever
T07
7.05 mm short lever
T13
13.15 mm lever
T19
20.95 mm lever
T28
28.35 mm lever
T43
43.55 mm lever
S26
6.25 mm simulated lever
A05
4.85 mm lever roller
Circuitry
C
SPDT
W
SPST N.C.
Y
SPST N.O.
Wire Type AWG
20
20 AWG
22
22 AWG
24
24 AWG
26
26 AWG
28
28 AWG
30
30 AWG
Wire UL #
(when required)
A
UL1007
B
UL1015
C
UL1430
D
UL1061
E
UL1330
Terminations
S
Solder
Q
0.110 Quick Connect
P
PC Thru Hole
W
Wire leads potted
Z
Wire leads non-potted
Wire Side (when required)
A
Wire out the bottom
B
Wire out the right side
C
Wire out the left side
D
None
Dimensions are shown: mm
Specifications and dimensions subject to change
J–26
www.ck-components.com
What products is LINUX used in?
Excuse me Do embedded product development , but this product does not need communication, such as 485 or wireless communication , nor does it need a fancy human-computer interaction interface, such as...
qintianming Linux and Android
Looking to buy Siemens 300PLC, if you have any, please contact me!
I need to purchase some Siemens modules for my project, [backcolor=rgb(255, 255, 255)][size=14px]315-2DP, AI, AO, DI, DO, new or second-hand are both acceptable. It's too late to transfer the goods. I...
回收西门子PLC Buy&Sell
Qingyuefeng and DXP insider design detailed penetration (Part 2)
1. Add and set vias. You can directly use the hotkey TAB to add routing vias (Via) in DXP. You can automatically add vias by setting different routing layers in Layer. Be sure to determine one point f...
tsingyue PCB Design
I'm kneeling in the snow and ice to ask about the driver installation problem (if the problem is solved, 100 points will be given)
I'm kneeling to ask about the driver installation problem (100 points will be given if the problem is solved) My driver development environment is WINNT4+VC6+NT4DDK+DriverStudio2.5. I use DriverStudio...
microwave1 Embedded System
A person's life is like riding a bus.
We know it has a beginning and an end, but we cannot predict what it will experience along the way....
1234 Talking
Test data and measured waveform of 100kHz/1000W high-efficiency full-bridge soft-switching regulated power supply
Yan Yangguang, Nanjing University of Aeronautics and Astronautics (Nanjing 210016) Abstract: A cheap and efficient 93.5% 100kHz, 1000W phase-shifted ZVS full-bridge soft-switching power supply can be ...
zbz0529 Test/Measurement

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 2908  2419  1503  831  318  59  49  31  17  7 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号