EEWORLDEEWORLDEEWORLD

Part Number

Search

DC322E474MA5610

Description
Feed Through Capacitor, 1 Function(s), 200V,
CategoryAnalog mixed-signal IC    filter   
File Size113KB,4 Pages
ManufacturerAVX
Download Datasheet Parametric View All

DC322E474MA5610 Overview

Feed Through Capacitor, 1 Function(s), 200V,

DC322E474MA5610 Parametric

Parameter NameAttribute value
Is it lead-free?Contains lead
Is it Rohs certified?incompatible
MakerAVX
Reach Compliance Codenot_compliant
ECCN codeEAR99
Other featuresSILVER TERMINATION
capacitance470000 µF
diameter8.51 mm
filter typeFEED THROUGH CAPACITOR
high2.54 mm
Minimum insulation resistance10000 MΩ
Manufacturer's serial numberDC32
Installation typePANEL MOUNT
Number of functions1
Maximum operating temperature85 °C
Minimum operating temperature10 °C
physical sizeD8.51XH2.54 (mm)/D0.335XH0.1 (inch)
Rated voltage200 V
Discoidal MLC
Feed-Through Capacitors and Filters
DC Style (US Preferred Sizes)
APPLICATION INFORMATION ON DISCOIDAL
LOWEST CAPACITANCE IMPEDANCES TO GROUND
A discoidal MLC capacitor has very low impedance associated with its ground path since the signal is
presented with a multi-directional path. These electrode paths, which can be as many as 100, allow for low
ESR and ESL which are the major elements in impedance at high frequencies.
The assembled discoidal element or feed-thru allows signal to be fed in through a chassis or bulkhead,
conditioned as it passes through the discoidal, and isolated by the chassis and discoidal from the original
signal. An example of this application would be in an AFT circuit where the AC noise signal would be required
to be stripped from the DC control signal. Other applications include single line EMI/RFI suppression, L-C
filter construction, and coaxial shield bypass filtering.
The shape of the discoidal lends itself to filter construction. The short length allows compact construction
where L-C construction is desired. The size freedom associated with this element allows almost any inside/
outside diameter combination. By allowing the inside diameter to equal the center insulator diameter of a
coaxial signal line and special termination techniques, this device will allow bypass filtering of a floating shield
to ground.
* Discoidal capacitors are available in two (2) temperature coefficients (C0G, X7R) and a variety of shapes
and sizes, the most standard of which appear on pages 102 and 13.
* Custom designed capacitor arrays are available in an unlimited number of configuration with a wide
range of rating voltages (50–2000) and temperature coefficients (NPO, BX, BR, X7R) please see page 121.
For additional information please contact AVX.
INSERTION LOSS
0
-10
OD*
ID
T Max.
These surfaces are metallized
.127 (0.005). minimum wide except
for DC61, DC26 and DC63
where metallized surfaces
are .127 (0.005) maximum.
*Tol. = +.254 (0.010) or 3%, whichever is greater
-
AVX’s DC Series 50V, 100V, 200V, C0G
and X7R parts are capable of meeting
the requirements of MIL-PRF-31033.
-20
-30
SINGLE CHIP
(dB)
-40
-50
-60
-70
-80
0
100
200
300
400
500
600
DISCOIDAL
700
800
900
1000
ELECTRICAL SPECIFICATIONS
Temperature Coefficient
C0G: A Temperature Coefficient - 0 ±30 ppm/°C, -55° +125°C
X7R: C Temperature Coefficient - ±15%, -55° to +125°C
Capacitance Test
(MIL-STD-202 Method 305)
C0G: 25°C, 1.0±0.2 Vrms at 1KHz, for ≤100 pF use 1 MHz
X7R: 25°C, 1.0±0.2 Vrms at 1KHz
Dissipation Factor 25°C
C0G: 0.15% Max @ 25°C, 1.0±0.2 Vrms at 1KHz, for ≤100 pF use 1 MHz
X7R: 2.5% Max @ 25°C, 1.0±0.2 Vrms at 1KHz
Insulation Resistance 25°C
(MIL-STD-202 Method 302)
C0G and X7R: 100K MΩ or 1000 MΩ-μF, whichever is less.
f (MHz)
Insulation Resistance 125°C
(MIL-STD-202 Method 302)
C0G and X7R: 10K MΩ or 100 MΩ-μF, whichever is less.
Dielectric Withstanding Voltage 25°C
(Flash Test)*
C0G and X7R: 250% rated voltage for 5 seconds with 50 mA max
charging current. 500V rated units will be tested at 750 VDC
Life Test
(1000 hrs)
C0G and X7R: 200% rated voltage at +125°C
(500 Volt units @ 600 VDC)
Moisture Resistance
(MIL-STD-202 Method 106)
C0G, X7R: Ten cycles with no voltage applied.
Thermal Shock
(MIL-STD-202 Method 107, Condition A)
Immersion Cycling
(MIL-STD-202 Method 104, Condition B)
HOW TO ORDER
DC61
5
A
561
K
A
Test
Level
A = Standard
Not RoHS Compliant
5
1
06
AVX
Voltage Temperature
Style
50V = 5
Coefficient
See Pages 100V = 1
C0G = A
119-120 200V = 2
X7R = C
500V = 7
Capacitance Code
Capacitance
(2 significant digits
Tolerance
+ no. of zeros)
C0G: J = ±5%
Examples:
K = ±10%
M = ±20%
10 pF = 100
X7R: K = ±10%
100 pF = 101
M = ±20%
1,000 pF = 102
22,000 pF = 223
220,000 pF = 224
Termination
Inside
Maximum
5 = Silver
Diameter
Thickness
(AVX Standard) See Pages 04 = 1.02 (0.040)
A = Unterminated 117-119 06 = 1.52 (0.060)
7 = SnNi w/Aμ Sputter
10 = 2.54 (0.100)
(100μ inches)
For dimensions, voltages or values not specified, please consult factory.
118
Electronic competition exchange
[i=s]This post was last edited by paulhyde on 2014-9-15 03:02[/i] Could you please send me a copy, thanks, [url=mailto:1015133791@qq.com]1015133791@qq.com[/url]...
msayhello Electronics Design Contest
[AN-757 Application Note] ADN2812 acquisition time
Introduction: When the ADN2812 uses the default working mode (i.e. locking to the input data mode), it can automatically lock to the input data mode without programming and external reference clock as...
EEWORLD社区 ADI Reference Circuit
I have to say that the old technology I have been exposed to since 2008 was still blocked at that time.
1-3. Input and output matching circuit The purpose of the matching circuit is to choose a way of acceptance. For those transistors that want to provide greater gain, the way is to accept and output it...
btty038 RF/Wirelessly
【MicroPython】Micropython PM detection
[i=s]This post was last edited by lkl0305 on 2016-6-13 14:53[/i] Today I would like to share with you a small experiment on PM2.5 detection using Micropython, using the climbing laser pm2.5 sensor pms...
lkl0305 MicroPython Open Source section
Calibration of medical devices
Calibration of medical devices 1. Thermometer calibration - use black body furnace + constant temperature water bath to calibrate two points 2. Sphygmomanometer calibration - using BP pump sphygmomano...
QWE4562009 Test/Measurement
AT89C2051 and STC microcontroller, which one is cheaper in the market?
Friends who know please tell me....
clark 51mcu

EEWorld
subscription
account

EEWorld
service
account

Automotive
development
circle

Robot
development
community

Index Files: 811  1095  376  1905  2475  17  23  8  39  50 
Datasheet   0 1 2 3 4 5 6 7 8 9 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Room 1530, 15th Floor, Building B, No. 18 Zhongguancun Street, Haidian District, Beijing Telephone: (010) 82350740 Postal Code: 100190
Copyright © 2005-2026 EEWORLD.com.cn, Inc. All rights reserved 京ICP证060456号 京ICP备10001474号-1 电信业务审批[2006]字第258号函 京公网安备 11010802033920号